SECTION 4 –
APPLIANCES AND SYSTEMS
4-8
The propane level is registered by a sending
unit on the tank. The gauge mounted on the side
of the tank will give a more accurate indication of
actual tank level if needed.
Water Pump Switch
When you want to use the self-contained
water system, turn on the “Water Pump” switch
on the monitor panel. The “Pump On” light will
illuminate when the pump switch is turned on.
Water will be available as soon as a faucet is
opened.
For your convenience, a switch is also located
in the water center compartment.
Battery Voltage Meter
Press the “House Battery” switch position to
check the level of charge (voltage) in the 12-volt
house batteries.
Press the “Engine Battery” position to check
chassis battery charge.
To get an accurate reading;
1. Both the chassis engine and the generator
engine must be shut off.
2. An interior light should be turned on to
provide a small load which draws off the
battery surface charge.
The LCD display will show the current battery
voltage to the nearest tenth of a volt.
•
A 12-volt battery typically registers anywhere
from 12.5V to 13V when adequately charged.
•
Voltage below 12V indicates a moderately
discharged condition; 11.5V or less is
extremely discharged.
•
Voltage above 13V typically indicates that the
battery is being charged by the inverter
charger system.
SOLAR CHARGER PANEL
The 10-watt roof-mounted solar charger panel
uses the sun to help keep your house batteries
charged. A charge indicator light is provided on
the OnePlace
®
panel to show you when the solar
panel is actively charging the house batteries.
Water Pump Switch
-Typical View
-Typical View
Solar Charging Indicator
• Glows when charging
• Full glow means maximum charge rate
• Gradually dims as batteries charge
• Goes off when batteries fully charged