13-5
SECTION 13
– Slideout Room
Class A
13 – Slideo
ut Room
Error Codes -
The DigiSync slideout system is equipped
with onboard diagnostics capabilities. In the
event of a system failure the green LED on the
left side of the control panel will blink to display
several possible error codes. An error code will
not be displayed unless the “IN” or “OUT”
control panel buttons has been pressed. For
example, the control panel will not display an
error code for low battery voltage unless you are
trying to extend or retract the room when low
voltage is present. Therefore it is a good idea if
you have an error code to write down which error
code you experienced to report it to your
authorized service center. This information will
help the service technician identify the cause of
the problem that you experienced.
When an error is detected, the green LED on
the left side of the control panel will blink. The
error code can be determined by counting the
number of flashes in between each pause. See the
Error Codes chart below for details. The error
code may be cleared at any time by pressing the
Reset button, or by allowing the system to ‘time
out’ after 60 seconds. Once cleared, the operation
can be tried again. If the error code appears again,
see Manual Mode and or Crank Mode.
Note:
Manual Mode and corresponding Front and Rear Actuator
locations
Front Actuator: Retract/In button
Rear Actuator: Extend/Out button
See your dealer for service of the slideout system
before using again.
BEDROOM SLIDEOUT
EMERGENCY RETRACTION
PROCEDURE
Models 29RR, 34AR & 35NR
1. Locate the tools in the right front side storage
compartment – a ratchet wrench, a hex-end
shaft and an extension shaft. (The ratchet
wrench may be packaged in the Owner
InfoCase.)
ERROR CODES
#Flashes
Problem
Description
1
Unit Timed Out
(ran for 60 sec with-
out reaching end of
stroke)
3
Battery Voltage less
than 10 volts
(detected when move
requested)
4
Battery Voltage less
than 8 volts
(detected during
move)
5
Battery Voltage
greater than 18 volts
(detected when move
requested)
6
Stall on Rear Actua-
tor only
(Indicates obstruc-
tion at rear of room
or jam)
7
Stall on Front Actua-
tor only
(Indicates obstruc-
tion at front of room
or jam)
8
Short Detect on Rear
Motor
(Rear motor is faulty
or wiring harness
faulty)
9
Short Detect on Front
Motor
(Front motor is faulty
or wiring harness
faulty)
10
No Current Detect on
Rear Motor
(Rear motor is faulty
or wiring harness
faulty)
11
No Current Detect on
Front Motor
(Front motor is faulty
or wiring harness
faulty)
12
No Encoder Signal
detected on Rear
Actuator
(Faulty encoder/har-
ness)
13
No Encoder Signal
detected on Front
Actuator
(Faulty encoder/har-
ness)
14
Rear Actuator did not
re-sync with Front
Actuator within 5
seconds
15
Front Actuator did
not re-sync with Rear
Actuator within 5
seconds
ERROR CODES