SECTION 10 -
SLIDEOUT ROOMS AND LEVELING
10-6
If an error is detected on your slide system, the
LED light on the control panel will blink an error
code. If an error code appears, see the
manufacturer’s user guide in your InfoCase to
determine the problem. The error code must be
cleared prior to operating the room. To clear the
error, perform the following steps (one at a time)
to reset the system:
•
If none of the “Battery Voltage or Circuit
Breaker Problems” troubleshooting
recommendations reset the system, remove
the touchpad from the monitor panel (a
screwdriver will be needed) and press and
hold the RESET button (“Set Stops/Clear
Fault”) located on the back of the touchpad for
5 seconds. The slideout is now ready to be
extended. Press OUT on the touchpad to
extend the room.
•
If touchpad was removed, reinstall to the wall.
•
Take your RV to an authorized service center
for repair.
Further Information
See the slideout room operating guide
included in your InfoCase for further instructions
and troubleshooting information.
SLIDEOUT EMERGENCY
RETRACTION – ELECTRIC
(Front Slideout Room)
-If Equipped
Crank-In Procedure
If the slideout mechanism is malfunctioning
and will not retract using the buttons, you will
need to manually crank the room in to the travel
position.
NOTE: The room can also be cranked out into
the extended position using this method,
if necessary.
The slideout crank tools are stored in clips on
the wall of an exterior storage compartment.
The crank sockets are located behind the
exterior storage compartment doors below the
ends of the room.
•
Insert the crank handle into the gear shaft
socket, aligning the notches in the crank
handle with the pins inside the socket as
indicated. Insert the second crank at the other
end of the room.
Light will flash fault
code if system
malfunctions
Light will flash if
park brake not set
Low Voltage
Indicator
Slideout Cranks (Typical View)