7-15
SECTION 7 –
PLUMBING
5. Turn the water supply faucets OFF.
Disconnect the inlet hoses from the faucets.
Drain any remaining water from the hoses.
6. Washer/Dryer is now winterized.
7. Go back to step 9 of “Blow-Out Procedure”.
Method 2–
Adding RV Antifreeze
If you are currently pumping RV antifreeze
through the fresh water system, follow these
steps to winterize:
1. With the machine power OFF, turn the WASH
TEMP knob to HOT.
2. Advance the Program Selector knob to
REGULAR in Cotton Heavy Duty.
3. Press the ON/OFF button (IN) and let the
machine fill until antifreeze is in the drum.
4. Advance Program Selector to a RESET. Wait
5 seconds (Status/Door Lock LED will blink).
5. Advance Program Selector to a SPIN
position. Let the antifreeze drain from the
drum.
6. Advance Program Selector to RESET. Wait 5
seconds (Status/Door Lock LED will blink).
7. Turn the WASH TEMP knob to COLD.
8. Advance the Program Selector knob to
REGULAR in Cotton Heavy Duty.
9. Let the machine fill until you see antifreeze in
the drum.
10. Advance the Program Selector knob to
RESET. Wait 5 seconds (Status/Door Lock
LED will blink).
11. Advance the Program Selector knob to SPIN.
Let the antifreeze drain from the drum.
12. Press the ON/OFF button (OUT).
13. Washer/Dryer is now winterized.
14. Go back to step 9 of “Blow-Out Procedure”.
To use washer/dryer again:
Flush antifreeze from the waterlines, then
1. Reconnect the water inlet hoses to the
corresponding HOT/COLD faucets. Turn the
faucets ON.
NOTE: Check the water inlet hoses and pump
periodically. Refer to the “Use & Care
Guide” that came with the machine.
2. Plug the washer/dryer into an appropriate
electrical outlet (or reconnect power supply).
3. With the ON/OFF button in the off (OUT)
position, pour 1/2 TBSP. of powder detergent
(or liquid equiv.) into the “Detergent”
compartment inside the Dispenser Drawer.
4. Advance the Program Selector knob to an
EXPRESS cycle.
5. Press the ON/OFF button (IN) and allow the
machine to run through the complete cycle to
clean out any remaining antifreeze.
WATER SYSTEM DRAIN VALVE LOCATIONS
System
Drain Valve Locations
Waterline Drain Valves:
•
35A and 35Z Models: Compartment in front of right rear wheel
lip.
•
32H and 38N Models: Compartment behind entrance door.
Water Tank Drain Valve:
•
32H and 38N Models: Compartment behind entrance door.
•
35A and 35Z Models: Compartment in front of right rear wheel
lip.
Water Heater Drain:
Drain plug on outside of coach behind service door. Use socket
to remove drain plug.
Winterization Valve 1:
(Water Heater Bypass)
Bypass valve is located in the utility compartment on the
passenger side of the coach.
Winterization Valve 2:
(Antifreeze Siphon)
Valve with clear vinyl siphon tube is located in the utility
compartment on the passenger side of the coach.