SECTION 7 –
PLUMBING
7-8
•
Open both Hot and Cold waterline valves.
•
Turn water diverter valve to WATER TANK
FILL position.
The fresh water tank drain valve is operated
by pulling on a T-handle for a cable that is
located in an exterior compartment.
Water Heater Drain Plug
The water heater drain plug is located on the
outside of the coach behind the water heater
service panel. Use a socket to remove the plug.
WATER HEATER BYPASS
WINTERIZATION VALVE
Your coach may be equipped with a water
heater bypass valve for easier winterization of
waterlines using RV antifreeze. See Water
System Drain Valve Locations chart at the end of
this section for valve location on your model.
Turn the handle as shown to either Bypass or
Normal flow through the water heater.
Waterline Drain Valve
-Typical View
Water Tank Drain Valve - Model 38N shown
(pull to drain)
-Typical View
Water Heater Service Access
-Typical View
Drain