![Winmate R20L100-RKA2ML Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/winmate/r20l100-rka2ml/r20l100-rka2ml_user-manual_987044045.webp)
User Manual
Appendix B
MIL-STD-810E/F Compliance
Military Grade Rack Mount Display
45
Appendix B MIL-STD-461E/F Compliance
This section includes information on testing methods and procedures in compliance with
military standard MIL-STD-461 E/F.
To comply with MIL-STD-461E Standard, the Display
must have Built-in EMI -ITO Glass or Touch with EMI Mesh Film.
B1 MIL-STD-461E/F Compliance
MIL-STD-461E/F Compliance
Test
Description
Type
Frequency Range
CE101
Power Leads
Conducted Emission
30 Hz ~ 10 kHz
*CE102 Power Leads
Conducted Emission
10 kHz ~ 10 MHz
CS101
Power Leads
Conducted Susceptibility
30 Hz ~ 150 kHz
CS109
Structure Current
Conducted Susceptibility
60 Hz ~ 100 kHz
CS114
Bulk Cable Injection
Conducted Susceptibility
10 kHz ~ 200 MHz
CS116
Damped Sinusoidal Transients,
Cables and Power Leads
Conducted Susceptibility
10 kHz ~ 100 MHz
RE101
Magnetic Field
Radiated Emission
30 Hz ~ 100 kHz
*RE102 Electric Field
Radiated Emission
10 kHz ~ 18 GHz
RS101
Magnetic Field
Radiated Susceptibility
30 Hz ~ 100 kHz
RS103
Electric Field
Radiated Susceptibility
2 MHz ~ 18 GHz
*Default Test