VIEW OF CIRCUIT BOARD IN EA800 BASE CONSOLE

1

Wired Sensor Inputs

S

PECIFICATIONS

EA800 Console Input Voltage

11 to 26VDC @ ≤ 500mA current draw

Wireless Sensor Input Voltage
(EA-WMFS, EA-WTS, EA-WHS)

12VDC @ ≤ 100mA current draw via 2.1 mm barrel plug, 
center positive 

OR

 2xAA Alkaline Batteries (1.5V Cell)

EA800 Console Auxiliary Output 
Voltage

Equivalent to DC Input Voltage used: 11 to 26VDC. 
(Maximum output current 0.5A).

Environmental Operating Range
(EA800, EA-WMFS, EA-WTS, 
EA-WHS)

Temperature: 0°C to 50°C (32°F to 122°F). Not for 
installation inside coolers or freezers.
Humidity: 5% to 95% RH, non-condensing.

Ambient Environmental Quality

Indoor use intended, non-corrosive environment.

Relay Contact Ratings

Max 30VDC @ 1 Amp, resistive

EA800 Real-Time Clock Battery

CR2032 (3V Cell)

Ethernet (EA800-ip only)

10/100BASE-TX/FX; fully compliant to IEEE 802.3u standard

Q

UICK

 S

TART

 G

UIDE

This guide provides basic setup instructions for the  
EnviroAlert EA800 and EA800-ip Critical Condition 
Monitoring System and associated sensors. Installers 
should refer to the Installation Manual (found online 
at www.winland.com) for complete instructions and 
specifications, and to become familiar with the many 
features provided by the EA800. The EA800 allows 
connection of up to 4 wired and 4 wireless sensors.

To use the EA800-ip’s advanced features, set up an 
account at www.ea800ip.com. Since the EA800-ip 
utilizes a cloud computing architecture, no client 
software is required.

R

EAD

 

THE

 I

NSTALLATION

/O

WNER

S

 M

ANUAL

 

FOR

 

COMPLETE

 

INSTRUCTIONS

.

Installation/Owner’s Manual can be found online at www.winland.com

•  All power terminals must be connected to a Class 2 power limited circuit complying with 

National Electrical Code NFPA 70, Article 725. Where required, this equipment is to be 
isolated from the main supply by a limited power source as specified in EN60950.

•  Batteries shall not cause explosion or produce a fire hazard as a result of excessive charge 

or discharge.

•  Ensure all wiring for wired sensor connections is done before powering on or 

programming the EA800 console.

•  If the equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

1950 Excel Drive  •  Mankato, MN  56001 USA

(Tech Support 8:00am - 5:00pm Central)

(800) 635-4269  •  (507) 625-7231 P •  (507) 387-2488 F

www.winland.com

I

NSTALLATION

 O

VERVIEW

1.  Installing Base Console

Do not connect or disconnect power, sensor, or alarm wiring 
while power is applied. Connecting and disconnecting the 
EA800 base console with power connected may damage the 
base console or result in improper or unreliable operation.
Connection of unsuitable loads to this connection may 
damage the power supply and EA800 base console, or result 
in improper or unreliable operation.

Using a terminal block adapter, connect power supply 

+

 and 

-

 leads to 

POWER IN

 (

+

) and 

(

-

) on 

J5

. Observe proper polarity.

EA800 Input Voltage:

 11 to 26VDC at ≤ 500mA

Note: 

The input voltage specification does not include requirements for loads connected to 

Aux Power Out.
If 

Aux Power Out

 is to be used, connect 

+

 and 

-

 leads to 

AUX POWER OUT

 (

+

) and (

-

) on 

J5

 using a terminal block adapter. When base console is powered, a 30-minute timer starts. 

The console will alarm after this timer expires unless one or more sensors are installed.

D-011-0153  Rev F (02/2012)