background image

WHERE TO USE

12~18 in

12~18 in

12~18 in

12~18 in

Allow 12 ~ 18 in. of space between TVs, radios, and other 

electronics

Electromagnetic interference from certain electronics may 

cause product malfunction.

Place indoors away from direct sunlight

Direct exposure may cause product malfunction or failure.

Only place on hard, flat surfaces

Flimsy or slanted surfaces may result in abnormal noise and 

vibrations.

Allow at least 12~18 in. from walls for maximum air flow

FRONT

PACKAGE CONTENTS

Air Outlet

Vent

Handle

Power Plug

Control Panel

Front Panel

Unit

(1) Pre-Filter

(4) Activated Carbon Filters

(1) True HEPA Filter

User

Manual

MODEL PART DIAGRAM

10

11

14

15

12

13

09

02

03

04

05

07

08

01

06

01. Auto Indicator

Indicates whether Auto Mode is enabled or 

disabled.

02. Sleep Indicator

Indicates whether Sleep Mode is enabled or 

disabled.

03. PlasmaWave

®

 Indicator

Indicates whether PlasmaWave

®

 is enabled or 

disabled.

04. Fan Speed Indicator

Indicates the current fan speed.

05. Timer Indicator

If timer has been set, the LED light indicates the 

set time of operation.

06. Filter Replacement Indicator

LED light indicates when it is time to change the 

filter.

07. Light Sensor

Detects the amount of ambient light in the 

environment.

08. Smart Sensor

Detects the amount of odorous gas in the 

environment. When in Auto mode, the fan speed 

adjusts according to the detected amount of gas.

09. Power Button

Turns the unit on or off.

During the first 30 seconds of powering up, the 

Air Quality Indicator will cycle through Blue, 

Amber and Red colors. Smart Sensor takes 

approximately 4 minutes to detect the air quality in 

the environment before normal operation begins.

10.  Mode Button

Press to cycle through to set the mode of operation 

(Auto, Sleep). The unit will default to Auto with 

PlasmaWave

®

 enabled when first powered on.

CONTROL PANEL

INITIAL OPERATION

1.  Remove the front panel by grasping its upper 

edge and gently pulling forward.

2.  Remove the Pre-Filter, then the plastic bag 

of filters behind it.

3.  Remove filters from protective plastic bag.
4.  Install the filters until they fit securely in 

place.

03. True HEPA Filter (back) 

02. Activated Carbon Filter (middle) 

01. Pre-Filter (front)

5.  After filters are installed, close the front 

panel.

6.  Insert the power cord into an electrical 

outlet.

Latch

02

03

01

Latch

When to Replace Filters 

Filter

Indicator Light When to Service

When to Replace

Pre-Filter

none

Clean once every 14 days

Permanent

Activated Carbon Filter

none

Can NOT be WASHED

Replace every 3 months

True HEPA Filter

Last Approx. 12 months

 • When the Check Filter Indicator LED is on, it is time to replace the True HEPA Filter and Activated 

Carbon Filter.

 • Intervals between filter replacement may vary depending on environment.

MAINTENANCE

REPLACING FILTERS

Resetting Filter Life:

 

After replacing your True HEPA Filter, place the Pre-Filter back in and close the 

Front Panel. While the unit is on, hold the Filter Reset Button for at least 5 seconds 

until you hear the beep. After the beep, the Filter Replacement Indicator will 

disappear. Your Winix True HEPA is now reset.

CLEANING CARE

Cleaning the Filters:

Use a vacuum cleaner or soft brush to clean the 

Pre-Filter

 • If it is excessively soiled, rinse in room 

temperature water. Do not use detergent or 

soap. Allow the filter to dry for 24 hours or more 

before using. Intervals between filter cleaning 

may vary depending on the air quality in the 

environment. 

Cleaning the Exterior & Interior:

1.  Open the front panel and clean the interior 

with a vacuum cleaner.

 • A handheld vacuum or hose attachment will 

work best.

2.  Dampen a cloth with room temperature water and 

wipe down the interior and exterior of the unit.

3.  Wipe the unit down with a clean, dry cloth.

 • Ensure no moisture remains before plugging 

the unit back in.

* For optimal performance, clean every 1 - 2 months. 

  N O T I C E

 • When cleaning the unit, always unplug the power cord first and then wait until the unit has cooled 

down.

 • Never disassemble, repair, or modify this unit yourself.

 • Do not use flammable sprays or liquid detergents.

 • Do not allow children to clean or maintain the unit.

 • Before cleaning or maintaining, ensure unit is unplugged.

 • Do not use benzene, alcohol, or other volatile fluids, which may cause damage or discoloration.

 • Do not use hot water over 104°F. 

 •

Auto Mode:

 - Auto Mode automatically adjusts fan speeds 

according to your indoor air quality. The fan 

speed will adjust to low when air quality is 

good, medium when fair, and to high when 

poor.

 •

Sleep Mode:

 - When Sleep Mode is activated, the Air 

Quality Indicator LED light is disabled.

 - Fan speed will automatically set to minimum 

speed (lower than 'Low') which will be nearly 

silent.

 - When Sleep Mode is active, PlasmaWave

®

 

will be disabled, but it can be turned back on.

11.  PlasmaWave

®

 Button

Enables or disables PlasmaWave

®

.

"When the unit is running, you may hear a chirping 

or buzzing sound. The sound is from large 

particles passing through PlasmaWave

®

, it is 

normal and does not signify product failure."

Press the PlasmaWave

®

 button when the unit is on 

to enable or disable this feature.

12.  Air Quality Indicator

Color coded LED light indicates one of three levels 

of Air Quality: Red (poor), Amber (fair), and Blue 

(good).

13. Fan Speed Button

Enables manual operation of the unit's fan speeds.

 • Press to cycle through and set the desired fan 

speed (Low, Medium, High, Turbo).

14.  Timer Button

Press to cycle through and set desired length of 

operation (1hr, 4hr, 8hr, [NO TIMER]).

15.  Filter Reset Button

After replacing the filter, turn on the unit and then 

use a thin object, such as a paper clip, to press the 

Filter Reset Button for 5 seconds.

UNIT SPECIFICATIONS

Model Name

5300-2

Dimensions

15 in(W) × 8.2 in(D) × 23.6 in(H)

Power Voltage

AC 120 V / 60 Hz

Weight

13.6 lbs

Power Rate

70 W

Replacement 

Filter

Filter A / SKU: 115115

Verified Room Size

360 sq.ft.

The exterior, design, and product specifications may be changed without prior notice to improve product performance.

Contact Winix for product related inquiries and customer service

 

Dedicated Call Center: 

 (877) 699-4649

 

Website: www.winixamerica.com

To expedite service, please specify the model name and number, the nature of the problem, your contact 

information, and your address.

True HEPA Filter

03

Activated Carbon Filter

02

PlasmaWave

04

Pre-Filter

01

®

4-STAGE AIR PURIFICATION

Air Purification means it 

removes inanimate particles

Отзывы: