NHPL-1836C-DGT

Operational Maintenance

& Service Bulletin for Models:

NHPL-1825-UNC

NHPL-1833-ECOC-2D-DGT

NHPL-1836-ECOC

Non-Insulated Economy

NHPL-1836C-DGT

NHPL-1836C

Non-Insulated Standard

NHPL-1825-UNC-DGT

NHPL-1825-UNC

Non-Insulated Universal Runner

NHPL-1810/HHC

Non-Insulated Undercounter 1/2 size

INHPL-1836C-DGT

INHPL-1836C

Insulated 

100% Pre-Tested Electrical Assembly

Содержание INHPL-1836C

Страница 1: ...erational Maintenance Service Bulletin for Models NHPL 1825 UNC NHPL 1833 ECOC 2D DGT NHPL 1836 ECOC Non Insulated Economy NHPL 1836C DGT NHPL 1836C Non Insulated Standard NHPL 1825 UNC DGT NHPL 1825...

Страница 2: ...packing and Installing 1 Maintenance and Caution 1 Power Supply 1 Operating Instructions Digital Drawer 2 Alarms and Conditions 6 Operating Instructions Analog Controls 8 Service Specifications 8 Reco...

Страница 3: ...u use ONLY the power cord supplied Use of a dedicated circuit should insure operational efficiency Do not operate the unit with an extension cord MAINTENANCE The equipment has been designed to require...

Страница 4: ...t Mode Box Temperature Setpoint will be displayed blinking and the unit will control Box Temperature based on the displayed setpoint After 10 seconds the display will change to show the Actual Box Tem...

Страница 5: ...3 digit display when in HEAT or PROOF mode The display can be configured for F C or N index based format If in N format the SETPOINT is displayed as a numeric value from 1 through 9 and the actual tem...

Страница 6: ...age 3 900 W 600 W 1500 W When initially entering HEAT mode or if the user increases the SETPOINT while in HEAT mode the Control uses Stage 3 to reach its setpoint as quickly as possible If during any...

Страница 7: ...L Table 1 Behavior Selected Units N Index Heater turns off temperature increasing Setpoint 2 F Heater turns on temperature decreasing Setpoint When Setpoints are displayed they are always flashing Whe...

Страница 8: ...low The Control has a LOW WATER indicator which is not included There is neither a sensor nor a detection technique implemented in its firmware This red LED is illuminated during the Lamp Test Functio...

Страница 9: ...e If an Alarm Condition is detected but goes away before being acknowledged its indication will continue until being acknowledged Fault Detected Detection Method Indication Effect on Operation Pushbut...

Страница 10: ...0 relative humidity The average will be approximately 85 relative humidity Service Specifications Heater Proofer Series Operating Instructions For Analog Drawer Series C Series 1 Push main power switc...

Страница 11: ...s Covered 180 Fish Baked Uncovered 175 Fish Fried Uncovered 180 French Fries Uncovered 185 Hamburgers Covered 180 Lasagna Covered 185 Potatoes Baked Uncovered 180 Potatoes Mashed Covered 175 Potatoes...

Страница 12: ...ater Element 170907 H 226 11 600W Heater Element 170915 H 227 12 600W Water Pan Heater Element 170923 H 228 12A Water Pan w studs 696482 H 242 13 Heat Control Knob 123916 H 108 14 Proofer Control Knob...

Страница 13: ...11 www winholt com fax 516 222 0371 800 444 3595 equipment winholt Electric Schematic Power Supply Digital Drawer NHP PD DGT...

Страница 14: ...12 800 444 3595 fax 516 222 0371 www winholt com equipment winholt Electric Schematic Power Supply continued Analog Drawer NHP PD ECO...

Страница 15: ...RD AGAINST THE RUNNER AND CABINET DO NOT FORCE WHEN IN THE CORRECT POSITION THE RUNNER SHOULD BE AT 90 DEGREES TO THE SIDE OF THE CABINET RUNNERS MUST BE REMOVED WITH A 4 MINIMUM SPACE ABOVE THEM TO R...

Страница 16: ...ve parts coverage only Administration of Warranty For assistance in filing a claim contact Winholt s Customer Care Department at 800 444 3595 Hablamos Espa ol All claims must be filed in writing and c...

Отзывы: