Marine Installation Manual
2021-08
3-5
3 Engine Installation
3.2 Conditions and requirements
X72DF
3.2
Conditions and requirements
3.2.1
Pressure and temperature ranges
Please refer to the document
‘Usual values and safeguard settings’
, which is
provided by WinGD under the following link:
Usual values and safeguard settings
For signal processing see also
3.2.2
Operating conditions
The engine can be operated without any restrictions in the ambient condition
range ‘winter’, as permissible by
, up to design conditions. Operation out
-
side these limits is possible, but further measures might need to be taken and the
power output might be limited (see
4.10.4 Outside ambient air temperature,
). For project-specific support please contact WinGD.
Reference conditions
Engine performance data
—
like BSEC, BSEF, tEaT and others
—
are based on
reference conditions. These conditions are specified in ISO standard 15550 (core
standard) and, for marine application, in ISO standard 3046 (satellite standard)
as follows:
Design conditions
The capacities of ancillaries are specified according to ISO standard 3046-1
(clause 11.4) following the International Association of Classification Societies
(IACS) and are defined as design conditions:
Air temperature before blower:
Engine room ambient air temperature:
Coolant temperature before SAC:
Barometric pressure:
Relative humidity:
25°C
25°C
25°C
1,000mbar
30%
Air temperature before blower:
Engine room ambient air temperature:
Coolant temperature before SAC:
Barometric pressure:
Relative humidity:
45°C
45°C
36°C
1,000mbar
60%