Legend
001
Mixing duct
005
Venting/sealing unit
002
Reactor
006
Urea solution supply unit
003
Turbine of turbocharger
007
Soot blowing unit
004
Engine
The HP SCR system can be operated, if the exhaust gas temperature after the exhaust gas
manifold is in the permitted limits shown in
Table 4-1 - Operation limits of exhaust gas temperature
. A temperature that is less than the given limit can cause the catalyst
elements to clog. A temperature that is more than the given limit can cause the catalyst elements
to age faster.
Tab 4-1
Operation limits of exhaust gas temperature after exhaust gas manifold
Operation mode
T
min
T
max
Preparation (urea injection OFF)
200°C
470°C
Use of low sulphur fuel (
≤
0.5% S) (urea injection ON)
310°C
470°C
Use of high sulphur fuel (> 0.5% S) (urea injection ON)
325 to 340°C
470°C
1
Refer to the HP SCR system documentation if the operation of the HP SCR system with
high sulphur fuel is permitted.
2
The engine control system (ECS) calculates this value related to the engine load and to
the exhaust gas pressure.
NOTE:
WinGD recommends to do a test of the valves regularly during engine stop, refer to
4.12.2
Operation modes
The HP SCR system has the operation modes that follow.
X72-B
AA00-9270-00AAA-043A-A
Operation Manual
HP Selective catalytic reduction system
Winterthur Gas & Diesel Ltd.
- 98 -
Issue 003 2021-12
Содержание X72-B
Страница 8: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 8 Issue 003 2021 12...
Страница 18: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 003 2021 12...
Страница 137: ...X72 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 137 Issue 003 2021 12...
Страница 301: ...7 Installation 7 1 Installation 302 X72 B Operation Manual Winterthur Gas Diesel Ltd 301 Issue 003 2021 12...