5.6.5
Scavenge air cooler
The scavenge air cooler (SAC) decreases the temperature of the hot compressed air from the
turbochargers. This increases the density of the air and thus increases the quantity of air that is
supplied to the cylinders.
The cooling water flows constantly through the tubes of the SAC and flows back to the cooling
water system of the plant.
). For maintenance you can remove the cover.
Fig 5-32
Scavenge air cooler (generic)
001
002
003
004
Legend
001
Air flow
003
Cooling water inlet
002
Cooling water outlet
004
Cover
WinGD recommends to regularly clean the scavenge air coolers, refer to section
scavenge air cooler during operation
. This prevents or decreases contamination of the scavenge
air coolers and thus increases the time between overhauls.