Winegard Company • 3000 Kirkwood Street • Burlington, IA 52601-2000
WARNING
INSTALLATION OF THIS ANTENNA NEAR POWER
LINES IS DANGEROUS. FOR YOUR SAFETY, FOLLOW
THE INSTALLATION INSTRUCTIONS.
High Definition (HD)
Platinum Antenna
90 DAY LIMITED WARRANTY
Winegard Company warrants this Winegard product against any defects in materials or workmanship within 90
(ninety) days from date of purchase. No warranty claim will be honored unless at the time the claim is made, you
present proof of purchase to an authorized Winegard dealer (if unknown, please contact Winegard Company,
3000 Kirkwood Street, Burlington, IA 52601-2000, Telephone 800-288-8094).
Winegard Company (at its option) will either repair or replace the defective product at no charge to you. This
warranty covers parts, but does not cover any costs incurred in removal, shipping or reinstallation of the product.
This limited warranty does not apply if the product is damaged, deteriorates, malfunctions or fails from: misuse,
improper installation, abuse, neglect, accident, tampering, modification of the product as originally manufactured
by Winegard, usage not in accordance with product instructions or acts of nature such as damage caused by
wind, lightning, ice or corrosive environments such as salt spray and acid rain.
The 90 Day Warranty is provided on the condition that the equipment is properly delivered with all handling
and freight charges prepaid to your Winegard dealer for return to our factory for repair or replacement. Winegard
dealers will arrange for the replacement or repair and return to you without charge the product which failed due
to defective material or workmanship.
WINEGARD COMPANY WILL NOT ASSUME ANY LIABILITIES FOR ANY OTHER WARRANTIES, EXPRESS
OR IMPLIED, MADE BY ANY OTHER PERSON.
ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING WARRANTIES OF
FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARE LIMITED TO THE 90-DAY PERIOD
OF THIS WARRANTY.
The foregoing shall be the sole and exclusive remedy of any person, whether in contract, tort or otherwise, and
Winegard shall not be liable for incidental or consequential damage or commercial loss, or from any other loss or
damage except as set forth above.
Some states do not allow limitations on how long an implied warranty lasts, or the exclusion of limitation of
incidental or consequential damages, so the above limitations or exclusions may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to
state.
Printed in U.S.A. © Winegard Company 2008 1451001
INSTRUCTIONS
VHF/UHF
MODEL HD7000R
HOW TO PROVIDE
LIGHTNING PROTECTION
FOR TV ANTENNA AND SET
Step 1.
Mount the grounding block as
close as possible to where the 75 ohm
coaxial cable downlead enters the house.
See Figure 8.
Step 2.
The ground wires for both the mast
and the downlead should be copper or
aluminum wire, number eight (8) or larger.
See Figure 8.
Step 3.
The downlead wire from the
antenna to the grounding block and the
mast ground wire should be secured to
the house spaced from four (4) to six (6)
feet apart. See Figure 8.
NOTE:
In the case of a “ground up” an-
tenna installation, it may not be necessary
to ground the mast if the mast extends
four or more feet into the earth. Consult
a TV serviceman for the proper depth in
your location.
Fig. 8
ATTACHING ANTENNA TO MAST
Loosen U-bolt nuts. Slide U-bolt over
mast. Point small end of antenna toward
stations and tighten securely. See Figure
7. The 75 ohm coaxial cable downlead
may be secured to mast by taping or by
using plastic wire ties.
ATTACHING THE COAX
Now that the antenna is secured to the
mast, connect the 75 ohm coaxial cable to
the matching transformer. The connection
should be finger tight. The coaxial down-
lead may be secured to the mast by either
taping it or use of plastic wire ties.
MASTING
2” OD MAX.
MAST CLAMP
MAST CLAMP
INSERT
HEX NUT
U-BOLT
Fig. 7
Antenna Lead
In Wire
Ground
Clamp
Electric
Service
Equipment
Antenna
Discharge Unit
(NEC Section 810-20)
Power Service Grounding
Electrode System
(NEC Art 250, Part H)
Ground
Clamps
Grounding Conductors
(NEC Section 810-21)
NEC - National Electrical Code
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70
Rev. 2/08