Humidity too high when unit is not
running
Possible Cause
Solution
System needs to run to dehumidify
Lower room temperature setpoint. Seal
openings around doors (gasket and sweep)
Humidity too high when unit is running
and cooling
Possible Cause
Solution
Too much moisture in cellar
Poor vapor barrier installation
Humidifier malfunction refer to the humidifier
instructions
Add dehumidifier to surrounding space
Other Miscellaneous Problems
System is leaking water
Possible Cause
Solution
Condensate pan plugged
Unit not level
Remove blockage and clean
Level with shims
System is running properly, but the sounds
of unit is objectionable
Possible Cause
Solution
Noise is from airflow
Duct airflow from condenser to outdoors
Problems Controlling Cellar Humidity