47
Cycling the Unit
The fans continue to free-wheel for several minutes when the unit cycles off. This is normal. If the
unit is furnished with a low ambient control, the condenser fan also cycles on and off during cooling.
This maintains the head pressure on the compressor under low ambient conditions, and is normal.
The bottom of the compressor stays warm even when the unit is off to keep the lubricating oil warm
and separated from the refrigerant.
Setting the Thermostat
Normal settings are between 54 and 58 degrees F. If the optional heating coil is furnished, enter a
separate temperature setting to maintain the lower setting. To prevent the unit from short cycling, the
setting between heating and cooling cannot be closer than 3 degrees F.
Regulating the Wine Cellar Temperature
Wine cellars have a natural temperature gradient of approximately 5 to 10 degrees F between floor
and ceiling. To increase or decrease the temperature in various zones, change the air flow patterns.
To keep the entire wine cellar at the same temperature, set the thermostat to run the supply fan
continuously and not just when the cooling is operating. Set Fan switch to ON instead of AUTO.
NOTE: To monitor the cellar temperature, place thermometers in various locations in
the cellar to monitor the temperature zones. Change the temperature in various zones
by shifting the air flow patterns.
Changing the Air Flow Direction
The grilles furnished with Wine Guardian are single directional. Rotate the grilles to change the
direction of the air flow.
When using multiple supply ductwork, balance the air flow between the ductwork. If too much air
flows though one duct but not enough air flows from the other duct, install a damper or other
restriction into the duct with too much air. That will force more air to flow out the other duct.
Содержание D0200
Страница 12: ...12 Overview Illustration of the Wine Guardian Unit Fig 1 Fig 2...
Страница 13: ...13 Overview Illustration of water cooled system Fig 3 Fig 4...
Страница 14: ...14 Wiring diagrams D025 and D050 Fig 5...
Страница 15: ...15 Wiring diagram D088 and D200 Fig 6...
Страница 16: ...16 Wiring diagram water cooled D025 and D050 Fig 7...
Страница 17: ...17 Wiring diagram water cooled D088 and D200 Fig 8...