Joining Communication Cable
Changing Jumper Positions
(Averaging readings from remote sensor)
If using multiple remote temperature/humidity
sensors in your application, refer to the photos
showing the need to change the jumper locations
internal to the control board on each remote sensor
(up to three maximum).
For the control to average all of the sensors utilized
(if more than one), the jumper must be in different
positions on the pins.
As you can see, there are three pin settings. To access
the jumper:
1. Remove the two-set screws holding on the
plastic cover. This procedure allows the control
to go to each remote sensor in sequence to
average. Failure to perform this procedure will
result in the system reading only one sensor
and not the average of multiple sensors.
NOTE: If multiple sensors control the Wine
Guardian unit, change factory default in
configuration setting 10 t
o “averaging.” You will
need access code from Air Innovations service to
use in configuration 8 to reach configuration 10.
Jumper position 1
Jumper position 2
Jumper position 3
IMPORTANT
Wine Guardian cooling systems are supplied with 50 feet of 6 wire, Cat 3 twisted pair
communication cable with RJ11 type connectors. Caution must be taken when connecting
two lengths of communication cable (splicing) to ensure uniform wire color before and after
splice. An RJ11 Modular 6 wire STRAIGHT THROUGH type coupler is the ONLY coupler
approved for splicing Wine Guardian twisted pair communication cable.
Содержание D0200
Страница 12: ...12 Overview Illustration of the Wine Guardian Unit Fig 1 Fig 2...
Страница 13: ...13 Overview Illustration of water cooled system Fig 3 Fig 4...
Страница 14: ...14 Wiring diagrams D025 and D050 Fig 5...
Страница 15: ...15 Wiring diagram D088 and D200 Fig 6...
Страница 16: ...16 Wiring diagram water cooled D025 and D050 Fig 7...
Страница 17: ...17 Wiring diagram water cooled D088 and D200 Fig 8...