Windhager FB 5210 Скачать руководство пользователя страница 1

Installation- 

a

nd 

Operation Instructions

Digital - 

Operation module

 FB 5210

02/01 023482/01

Содержание FB 5210

Страница 1: ...Installation and Operation Instructions Digital Operation module FB 5210 02 01 023482 01...

Страница 2: ...the heating circuit module of the corresponding heating circuit The first part of the booklet contains all the information needed to operate the module You will soon see just how simple and logical it...

Страница 3: ...e 12 3 7 Adjusting the time and day of the week 12 3 7 1 Summer winter time adjustment 13 3 8 Set holiday program 13 4 Checking temperatures displaying controller outputs 14 4 1 Checking temperatures...

Страница 4: ...ual values 26 6 1 3 Standard values switching on and off 26 6 1 4 Error messages 26 7 General 27 7 1 Installation information and preparation for Initial Operation 27 8 Explanation of terms 27 9 Techn...

Страница 5: ...ectrically operated Improper installation or attemp repair can result in a life threatening electric shock hazard Installation and commissioning must be performed only by adequately qualified speciali...

Страница 6: ...tween lead to a reset of the display The input value will be showed correctly in a very short time 2 2 User adjustments You the user can make the following controller adjustments Adjust desired room t...

Страница 7: ...amme 2nd level controls accessible after removing cover Time of day adjustment Programming key for room heating night reduction times Programming key for hot water times Desired hot water temperature...

Страница 8: ...emperature at a faster rate The change takes effect immediatley The display returns returns to normal after 1 minute or you can press the key to restore the normal display right away 3 1 2 Night reduc...

Страница 9: ...n see Checking temper atures displaying controller outputs starting from page 14 2 Press the or side of the key to adjust the displayed value on the operation module with the measured value on the roo...

Страница 10: ...h key press moves the maker one position to the right Symbol Function Recommended setting for Heating OFF Heating and domestic hot water OFF Frost protection active Automatic Heating and warm water ac...

Страница 11: ...n in example on the right heating is running at full power although it would normally be in night reduction mode at this time To turn off the Party function press the key again 3 5 Switching on domest...

Страница 12: ...ts Press and hold down the key to change the temperature at a faster rate The change take effect immediately The display returns to normal after 1 minute or you can press the key to restore the normal...

Страница 13: ...ion is during this time inhibited If you choose the holiday programme during the heating season and would like minimum temperature in the room Indoor plants you guarantee that the reduction temperatur...

Страница 14: ...symbol In order to interrupt the holiday prgramme earlier press the button The controller works now again according to the programme set 4 Checking temperatures displaying controller outputs 4 1 Check...

Страница 15: ...es measured values to the display Pressing the button once returns the basic display into the display This comes about also automatically if no button is not pressed for a minute Boiler temperature se...

Страница 16: ...the automatic programme are the times when the heating system switches on and off or release and off times for the hot water production ar active 4 standard programmes have been pre set at the factor...

Страница 17: ...00 23 00 Day group Room heating Hot water Day of week Marked days On Reduced Turn on Turn off Mon Thu 06 00 22 00 05 00 22 00 Fri 06 00 23 00 05 00 23 00 Sat 07 00 23 00 06 00 23 00 Sun 07 00 22 00 0...

Страница 18: ...fied The Adjustment examples on page 22 provides step by step explanation of how to customise the standard programmes 5 4 1 Selecting the standard programme The standard programme for room heating and...

Страница 19: ...hot water The programme comes into effect immediately Note The original programme will be overwritten and ereased The deisplay returns to normal after 1 minute or you can press the key to restore the...

Страница 20: ...the first day or day block appear in the display the example shows standard programme 3 The time marker is positioned at the start of the first heating period 2 If necessary move the time marker to d...

Страница 21: ...zur Normalanzeige zur ckschalten 5 4 3 Checking verifying automatic programmes You can check all the switching times for the current programme and the standard programmes 1 Press the key repeatedly t...

Страница 22: ...e room heat ing programm 3 Press the key The normal display returns The normal display will also return automatically after 1 minute Your changes are saved and come into effect immediately 5 5 2 Earli...

Страница 23: ...of the first heating period 3 Move the time marker to 5 30 using the key press the side 6 times 4 Use the key to add heat ing periods press the side to fill the intervening segments Your changes are...

Страница 24: ...llowing table 2 Compare your desired programme with the four standard programmes on page 18 3 Select the standard programme that is closest to your desired programme see Selecting the standard program...

Страница 25: ...the display If this is not the case the following explan ation could be of use In order to guarantee that the automatic controller and the pertinent devices are in functional state following activitie...

Страница 26: ...ler Set and actual values In accordance with procedure 4 3 set points scan from page 15 If all necessary measured values sensors are displayed and these are valid is to test through the set values if...

Страница 27: ...ject to operate the reset button If no main image appears please check the wiring 8 Explanation of terms 9 Technical data Operational start The operational start is the programmed start of the operati...

Страница 28: ...oves should be installed in the reference room Attention The temperature measured in this room has influence on the control characteristic of the whole heating circuit 10 2 Definition of the installat...

Страница 29: ...o press the to under the front plate hidden cams with your fingers Consider during the arrangement that the backside opening for the cables lies above the clamping block and the numbering in the casin...

Страница 30: ...e set in therefore through light side pressure from the catch and set in the other way For the wiring always note the numbering on the base plate Warning The connection cables from the operation to th...

Страница 31: ...ide of the controller have to be set to the required function DIP switch no 2 is always on OFF Warning Switch on the power supply on the boiler and therefore on the heating circuit module if all wirin...

Страница 32: ...on Windhager Str 20 Tel 0 62 12 23 41 262 Ger te Zubeh r Tel 0 62 12 23 41 264 Tel 0 62 12 23 41 268 Tel 0 62 12 23 41 0 Fax 0 62 12 42 27 Tel 0 62 12 23 41 265 Fax 0 62 12 45 04 Fax 0 62 12 42 26 Fax...