Externally Mounted Ventilators – Install Quick Specs 

VEN100E  

 

   

Installation Type & Discharge Direction   

Mounted outside.  Can be mounted on exterior 
roof or wall.

 

 

CFM Rating 

1000 CFM = VEN100E 
 

Minimum Duct Size  

10” round 
   

Maximum Equivalent Straight Duct Length 

50 feet 
 

Equivalent Straight Lengths 

  1 foot of 8” or 10” duct = 1 foot 

  1 foot of 3 ¼” x 14” rectangular = 1 foot 

  8” round 90 degree Elbow = 5 feet 

  10” round 90 degree Elbow = 3 feet 

  Wall or Roof Cap = 2 feet 

 

Standard 

Features 

    

  Adaptable to all Wind Crest hoods 

  Weather-resistant galvanized steel 

construction 

  Thermally protected, permanently 

lubricated motor 

  Dynamically balanced 11” diameter blower 

wheel 

  Neoprene resilient anti-vibration mounted  

  Built-in Flashing plate for roof or wall mount 

  Easily removed blower cover for periodic 

cleaning 

 

Ventilator Motor Ratings* 
Hoods without Heat Lamps: 

8.0 Amps @ 120 V AC, 60 Hz 

Hoods with Heat Lamps: 

12.4 Amps @ 120 V AC, 60 Hz 
*For maximum power supply required, refer to 
hood series selected. 

 
 

Ventilator Carton Weight: 

VEN100E  =  80 lbs.   
 
 
 