background image

8

OPM-110/D

Never use gasoline that has been stored for an extended 

period of time as the fuel will lose its volatile properties 

and you will be left with varnish residue. The varnish 

like substance will clog the carburetor and will not burn 

properly.

The use of fuel additives, such as Sta-Bil, or an equivalent 

will minimize the formation of fuel gum deposits. If a unit 

has been out of operation for an extended period of time, 

it is best to drain old fuel from the engine and replace with 

fresh fuel before attempting to start.

See the engine manual for special instruction for operating 

this unit at over 5000 feet.

BATTERY INSTALLATION

This engine generator set is shipped with a bungee cord 

for installation of the customer supplied battery in the unit’s 

battery tray. 

If you intend to use the unit’s electric start system, you will 

need to purchase and install a battery to operate it. A 12 

Volt battery, BCI group 26 rated at 500 CCA or larger is 

recommended for this electric start engine-generator set. 

Follow the battery manufacturers recommendations for 

servicing and charging prior to use. Connect the battery to 

the electric start system using the cables provided.

CAUTION: EQUIPMENT DAMAGE

These electric start engines are NEGATIVE GROUND. Use 

extreme caution when connecting the battery. Connect 

the NEGATIVE battery terminal to GROUND.

For your safety, always connect the positive battery cable to 

the “bat+” terminal first. Then connect the negative battery 

cable to the “Bat-” terminal. Make sure all connections are 

clean an tight. Reverse the sequence when disconnecting, 

disconnect the negative cable first. These engines produce 

enough direct current to keep the battery charged under 

normal operating conditions, but were not intended to be 

used as a battery charger.

WARNING: PERSONAL INJURY

Lead acid batteries produce explosive hydrogen gas when 

charging. Keep sparks, flames, and burning cigarettes 

away from the battery. Ventilate the area when charging 

or using the battery in an enclosed space. Lead acid 

batteries contain sulfuric acid, which causes severe burns. 

If acid contacts eyes, skin, or clothing, flush well with 

water. For contact with the eyes, get immediate medical 

attention.

BATTERY CHARGING

Units have a small flywheel charger built into the engine 

flywheel assembly for recharging the starting battery. This 

flywheel charger generates a small AC current that passes 

through a diode assembly to produce DC charging current 

of about 1 to 3 Amps. This circuit is not designed to be used 

as a battery charging circuit to recharge dead batteries.

LIFTING EYE INSTALLATION

The lifting eye is shipped loose along with a bag of parts. 

Install the base of the lifting eye below the middle support. 

See diagram below.

OPTIONAL DOLLY KIT

An optional 4-wheel dolly kit is available for this generator. 

The dolly kit comes with instructions and parts list. 

.3125-18 

Flange

Lifting 

Eye

Flat 

Washer

HHCS 

5/16

Содержание WL22000VA

Страница 1: ...tact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DA...

Страница 2: ...TOR MAINTENANCE CLEANING TROUBLESHOOTING 18 RECEPTACLE WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should...

Страница 3: ...20 C Stator Resistance 0 366 Ohms 20 C Exciter Rotor Resistance 1 453 Ohms 20 C Exciter Stator Resistance 15 71 Ohms 20 C AVR DSR ENGINE Engine Manufacturer Briggs Stratton Engine Model Number 613477...

Страница 4: ...with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back into closed room...

Страница 5: ...e performance these units should never be run in small compartments without positive fresh air flow RESTRICTED USES DO NOT remove from the cradle assembly Removal of the generator from the cradle asse...

Страница 6: ...about the same amount of current to run them whether they are Repulsion Induction RI Capacitor Cap or Split Phase SP type If the electric motor is connected to a hard starting load such as an air comp...

Страница 7: ...ator must be on a level surface before you check or add oil to the system The necessity of using the correct oil and keeping the crankcase full cannot be overemphasized Engine failures resulting from...

Страница 8: ...safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the Bat terminal Make sure all connections are clean an tight Reverse the sequenc...

Страница 9: ...asoline is blended to improve starting Do not use summer grade gasoline 2 HOT WEATHER A Use the proper oil for the temperature expected B Use only summer blended gasoline Using gasoline left over from...

Страница 10: ...nt Carefully evaluate your planned use of your generator to understand which grounding you require If you are not sure what to do contact a competent professional to assist you The NFPA 70 250 34 35 a...

Страница 11: ...of normal fusing 3 Many homes and construction sites are wired for at least 60 to 100 Amp entrance service much greater than the capacity of this portable generator When installing the generator at th...

Страница 12: ...load This will ensure the generator is balanced Balanced Unbalanced YOURGEN The WINCO YourGen meter allows you to see useful information about your generator from the front panel by displaying RPMs Vo...

Страница 13: ...ge will flash Once the oil has been changed press and hold the cycle button for approximately 5 seconds until the warning has been removed from the display to reset the warning The meter will then rem...

Страница 14: ...oroughly air dry DO NOT oil the pre cleaner 7 Install the pre cleaner F to the air filter E 8 Assemble the dry pre cleaner F to the air filter E 9 Install the air filter and secure with the retainer D...

Страница 15: ...installing Spark plug gap is 0 030 Poor spark will also occur if spark plug wire does not fit firmly on spark plug If this happens reform the terminal to fit firmly on spark plug tip CARBON CANISTER D...

Страница 16: ...Regulator The following is a list of connections on the AVR These have been factory set and other than voltage adjustment should never be changed VOLT Voltage Rotate clockwise to increase voltage STA...

Страница 17: ...ubrication B Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the...

Страница 18: ...stator Defective rotor field Defective AVR Circuit breaker trips Defective load Defective receptacle Excessive load Voltage too high Engine speed is too high Generator overheating Overloaded Insuffic...

Страница 19: ...19 OPM 110 D G1 G1 G2 G2 G2 N N N N N N N GND GND GND GND GND GND G2 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 G1 G1 G1 RECEPTACLE WIRING DIAGRAM...

Страница 20: ...a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use and service will be repaired o...