OPM-143/G
SPN
FMI Test Translation
DTC
2791
6
The Power stage of EGR Valve actuator is monitored by Hardware for electric failures.
The Power stage of electric EGR Valve actuator (H-Bridge) is monitored by Hardware for electric failures. The H-Bridge
has 2 switches (High side and Low side). Each circuit is monitored separately.
The Power stage of electric EGR Valve actuator (H-Bridge) is monitored by Hardware for electric failures. An overload
error is not detectable directly in case the wiring length is > 1m and the failure occurs near the actuator. Therefore a
plausibility check is made in case a failure “Short circuit to Battery” (SCB) or “Short circuit to Ground” (SCG) is detected.
Therefore the switch (Low side in case of SCB , High side in case of SCG) is closed. If the Short Circuit failure disappears, it
is cleared and the Overload failure activated.
AE7-6
2791
7
The EGR Valve actuator gives a feedback with a position sensor. If there is a positive deviation between required and
measured position, the failure is activated. The system tries then to ”unblock” the actuator closing or opening it fast. If it is
not possible to ”unblock” the actuator, the failure “Jammed Valve” is activated.
AE7-7
2797
6
Hardware errors in the injectors and respective ECM power stages are investigated. Diagnostic procedure uses pattern
detection to identify specific errors and trigger appropriate substitute reaction. The behavior pattern describes in a
bit mask different detected problem (over current, command collision, RAM error,short circuit,....) when the expected
combination of errors is detected (measured and reference pattern are matching) a failure is detected. Two banks are
present.
AED-6
2797
7
Hardware errors in the injectors and respective ECM power stages are investigated. Diagnostic procedure uses pattern
detection to identify specific errors and trigger appropriate substitute reaction. The behavior pattern describes in a
bit mask different detected problem (overcurrent, command collision, RAM error,short circuit,....) when the expected
combination of errors is detected (measured and reference pattern are matching) a failure is detected.
AED-7
2798
6
Hardware errors in the injectors and respective ECM power stages are investigated. Diagnostic procedure uses pattern
detection to identify specific errors and trigger appropriate substitute reaction. The behavior pattern describes in a
bit mask different detected problem (over current, command collision, RAM error,short circuit,....) when the expected
combination of errors is detected (measured and reference pattern are matching) a failure is detected. Two banks are
present.
AEE-6
2840
12
The hardware encapsulation of CY320 performs a diagnostic of the sensor supplies and monitors the communication
Between processor and voltage supply device CY320.
A functionality for reading writing and erasing values to a memory media (Flash or EEPROM) is available.
These operations are monitored and if problems arise a failure is reported.
Communication between CJ945 (power stage chips) and CY320 (power stage voltage supplier) is monitored.
The HWE-module R2S2 is the LowLevel Chipdriver for the Powerstage-Chips R2S25200kfp.
The R2S25200 is a chip with 18 powerstages and an additional module for the monitoring of the ECU internal 5V Supply-
Voltage. It is possible to configure max. 4 R2S2.
B18-C
2840
14
Calibrated parameters for baud rate cannot be read from EEPROM
B18-E
2880
2
A range and plausibility check for the value of PTO switch are performed. The source for the multi value PTO switch is an
analogic input.
B40-2
2880
3
A range and plausibility check for the value of PTO switch are performed. The source for the multi value PTO switch is an
analogic input.
B40-3
2880
4
A range and plausibility check for the value of PTO switch are performed. The source for the multi value PTO switch is an
analogic input.
B40-4
3242
0
Physical signal range check: Exhaust Temperature before EGR exit can not exceed physically 799,96°C. If the measured
value is higher, the sensor signal is not reliable.
CAA-0
3242
3
The electrical Signal of the Particle Filter temperature upstream sensor is monitored. In case of defect recognition a
substitute value is taken.
CAA-3
3242
4
The electrical Signal of the Particle Filter temperature upstream sensor is monitored. In case of defect recognition a
substitute value is taken.
CAA-4
3358
10
The system evaluates the main physical parameters of engine (intake temperature and pressure, lambda, EGR position,
temperature and pressure in exhaust path) in order to discover a leakage on path from compressor downstream and
intake path.
D1E-A
3509
2
The hardware encapsulation of CY320 performs a diagnostic of the sensor supplies and monitors the communication
Between processor and voltage supply device CY320. For reasons of safety the ECM provides 3 independent 5V voltage
supplies for the sensors. These sensor supply voltages are monitored to ensure they remain within a given range. This
check for voltage limits is done autonomously by the hardware (thresholds not applicable).
DB5-2
3510
2
The hardware encapsulation of CY320 performs a diagnostic of the sensor supplies and monitors the communication
Between processor and voltage supply device CY320.For reasons of safety the ECM provides 3 independent 5V voltage
supplies for the sensors. These sensor supply voltages are monitored to ensure they remain within a given range. This
check for voltage limits is done autonomously by the hardware (thresholds not applicable).
DB6-2
3511
2
The hardware encapsulation of CY320 performs a diagnostic of the sensor supplies and monitors the communication
Between processor and voltage supply device CY320. For reasons of safety the ECM provides 3 independent 5V voltage
supplies for the sensors. These sensor supply voltages are monitored to ensure they remain within a given range. This
check for voltage limits is done autonomously by the hardware (thresholds not applicable).
DB7-2
3719
0
When filter regeneration is insufficient, due too prolongated city driving cycle (low exhaust temperatures) or DOC is
damaged (no feed gas produced), filter flow resistance can increase above critical values.
E87-0
3719
16
When filter regeneration is insufficient, due too prolongated city driving cycle (low exhaust temperatures) or DOC is
damaged (no feed gas produced), filter flow resistance can increase above critical values.
E87-10