Safety

 

precautions

 

ATTENTION

:

 

Please

 

ensure

 

the

 

correct

 

connection

 

of

 

the

 

sockets

 

and

 

sleeves

 

The

 

strings

 

(+

 

and

 

 

cables)

 

are

 

fed

 

into

 

the

 

inverter

 

and

 

connected

 

to

 

the

 

DC

 

solar

 

inputs.

 

The

 

module

 

socket

 

are

 

marked.

 

The

 

cable

 

on

 

the

 

+

 

socket

 

of

 

the

 

module

 

should

 

be

 

connected

 

to

 

the

 

inverter

 

at

 

the

 

 

+

 

input.

 

The

 

same

 

procedure

 

applies

 

to

 

the

 

 

socket

 

and

 

 

input.

 

The

 

cables

 

can

 

be

 

laid

 

in

 

cable

 

grooves

 

in

 

the

 

cross

 

profiles.

 

Here

 

it

 

is

 

important

 

to

 

make

 

sure

 

that

 

no

 

water

 

remains

 

in

 

the

 

cable

 

grooves,

 

e.g.

 

if

 

the

 

roof

 

is

 

uneven.

 

If

 

necessary

 

drain

 

holes

 

can

 

be

 

drilled

 

into

 

the

 

groove.

 

Only

 

certified

 

socket

 

connectors

 

are

 

approved

 

for

 

connecting

 

the

 

solar

 

cables

 

to

 

the

 

modules

 

or

 

inverters

 

respectively.

 

The

 

socket

 

connectors

 

are

 

crimped

 

on

 

with

 

special

 

pliers

 

or

 

connected

 

to

 

the

 

modules

 

and

 

inverters

 

with

 

adapter

 

cables.

 

The

 

adapter

 

sets

 

are

 

connected

 

to

 

the

 

(approximately

 

6

 

mm

 

stripped)

 

end

 

of

 

the

 

cable.

 

Now

 

establish

 

the

 

crimp

 

connection

 

and

 

shrink

fit

 

the

 

shrink

 

tubing

 

over

 

the

 

connection

 

with

 

a

 

hot

air

 

gun

 

or

 

flame.

 

The

 

individual

 

strings

 

can

 

be

 

checked

 

for

 

polarity

 

and

 

voltage

 

with

 

a

 

multi

meter

 

/

 

voltmeter.

 

The

 

inverters

 

should

 

be

 

connected

 

in

 

accordance

 

with

 

the

 

manufacturer’s

 

instructions.

 

 

ATTENTION

:

 

Depending

 

on

 

yield

 

and

 

inverter,

 

different

 

string

 

lengths

 

are

 

possible.

 

It

 

is

 

essential

 

to

 

observe

 

the

 

assembly

 

instructions

 

and

 

connection

 

specifications

 

for

 

the

 

inverter!

 

Prior

 

to

 

connecting

 

to

 

the

 

inverter

 

check

 

that

 

each

 

of

 

the

 

individual

 

strings

 

is

 

de

energised.

 

 

It

 

is

 

absolutely

 

imperative

 

that

 

the

 

inverter

 

be

 

connected

 

to

 

the

 

public

 

power

 

supply

 

network

 

by

 

a

 

certified

 

specialist.

 

ATTENTION

:

 

High

 

direct

 

current

 

voltage

 

accrues

 

even

 

at

 

low

 

levels

 

of

 

radiation.

 

Never

 

touch

 

unprotected

 

+

 

and

 

 

cables

 

that

 

are

 

in

 

operation.

 

 

 

6.3

 

Earthing

 

 

Proper

 

earthing

 

on

 

the

 

module

 

frames

 

is

 

the

 

responsibility

 

of

 

the

 

solar

 

installer

 

or

 

installation

 

company.

 

If

 

an

 

external

 

lightning

 

protection

 

system

 

is

 

already

 

provided

 

or

 

planned

 

for

 

the

 

building,

 

the

 

photovoltaic

 

system

 

must

 

be

 

integrated

 

into

 

the

 

protection

 

concept

 

against

 

direct

 

lighting

 

strikes.

 

When

 

using

 

transformer

less

 

inverters,

 

earthing

 

should

 

be

 

carried

 

out

 

for

 

personal

 

safety

 

reasons.

 

The

 

earthing

 

point

 

is

 

marked

 

on

 

the

 

module

 

frame.

 

For

 

earthing

 

purposes,

 

an

 

M4

 

screw

 

is

 

prescribed.

 

Also

 

observe

 

the

 

national

 

standards.

 

 
 

7.

 

Cleaning

 

/

 

maintenance

 

 

As

 

the

 

operator,

 

you

 

should

 

regularly

 

remove

 

dirt

 

from

 

the

 

modules.

 

The

 

following

 

points

 

should

 

be

 

noted:

 

 

Never

 

stand

 

on

 

the

 

module

 

surface.

 

Do

 

not

 

exert

 

any

 

mechanical

 

loads

 

on

 

the

 

modules.

 

 

Do

 

not

 

clean

 

with

 

water

 

if

 

there

 

is

 

a

 

risk

 

of

 

frost

 

or

 

major

 

differences

 

in

 

temperature

 

between

 

the

 

module,

 

water

 

and

 

air.

 

 

We

 

recommend

 

decalcifying

 

hard

 

water.

 

This

 

will

 

prevent

 

lasting

 

water

 

stains.

 

Remove

 

standing

 

water

 

from

 

the

 

module.

 

 

Do

 

not

 

use

 

abrasive

 

cleaning

 

agents

 

or

 

tensides.

 

Do

 

not

 

scrape

 

off

 

dirt

 

as

 

this

 

may

 

damage

 

the

 

surface

 

of

 

the

 

module.

 

 

ATTENTION

:

 

Please

 

make

 

sure

 

that

 

the

 

earth

 

connection

 

is

 

not

 

interrupted

 

or

 

damaged!

 

 

 

Содержание WSP?M6

Страница 1: ...Installation Manual Crystalline module series WSP and WST ...

Страница 2: ...enance 8 Liability disclaimer 9 Contact From February 2014 this document applies to the WINAICO WSP and WST series and takes the place of all previous versions of the installation and mounting instructions for these modules No responsibility is accepted for the correctness of this information We reserve the right to technical changes The documentation in place at the time the module was manufactur...

Страница 3: ...ing instructions to hand at all times Information for operators Keep these instructions for the duration of the module s life Pay particular attention to the chapters on cleaning and maintenance and troubleshooting Before installing the solar system be sure to contact your local authorities and energy suppliers for the relevant guidelines and approval requirements You will only ensure the conditio...

Страница 4: ...ne Monocrystalline Polycrystalline Polycrystalline Area m 1 63 1 63 1 34 1 63 Weight kg 19 8 19 6 16 6 18 7 Max system voltage VDC 1 000 1 000 1 000 1 000 Max reverse current rating A 15 15 15 15 Connection type Tyco connection socket plug Tyco connection socket plug Tyco connection socket plug WINAICO connection socket plug MC4 intermateable Protection class IP 65 IP65 IP65 IP65 Fire class C C C ...

Страница 5: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com WSP P6 Blackline WST P6 ...

Страница 6: ... by the manufacturer so that the high voltage components can discharge Be sure to carefully follow the inverter manufacturer s installation instructions WINAICO modules are qualified for application class A Hazardous voltages IEC 61730 higher than 50V DC EN61730 higher than 120V DC hazardous power applications higher than 240W where general unrestricted access is anticipated Modules qualified for ...

Страница 7: ...rse current strength is 15 A 4 Transport and storage Check the shipment immediately upon delivery to ensure completeness and integrity Note any damage on the driver s consignment note and inform WINAICO in writing immediately The utmost care is required when handling the modules Take care when unpacking transporting and storing them Store the modules safely in cool and dry rooms The packaging is n...

Страница 8: ... least 15 In Central Europe a gradient of 30 is optimal Location The mounting site should be as free as possible from shade of any kind houses trees branches leaves cables antennas etc shade can significantly reduce the output of the solar modules Partial shade will also reduce the electric current yield A module is regarded as free of shade if the entire surface is free of shade throughout the ye...

Страница 9: ...ility of falling objects Secure the work area so that no other persons can be injured Keep children away from the installation site All parts of the module should be protected from mechanical loading e g caused by pressure tension torsional stress during transport and installation Ensure that the radius doesn t fall below the minimum permissible bend radius of 60 mm for cables at the connection so...

Страница 10: ... located on the rear side of the module in the upper section Figure Clamping on the short sides is not permitted Figure Reverse installation with connection socket pointing downward is not permissible Figure Observe specified clamping range The modules can be mounted to the substructure by clamping in place from the front or screwing on from behind The clamping area Example A for each fastening po...

Страница 11: ... or uneven structures can damage the module Note The middle clamps can be used as spacers between the module rows when mounting the modules To avoid any possible stresses and failure to comply with dimensions a gap should be maintained between the module rows We recommend a gap of approximately 2 cm For aesthetic reasons we recommend using black clamps for mounting our module series with black ano...

Страница 12: ...sert a suitably dimensioned protective diode into one of the two connection lines leading to this string such that these lie in the conductance direction in this string during the conventional generation of electrical energy i e so that the electrical current is able to pass through them In order to attain this it is necessary to connect the diode anode with the positive connection of this string ...

Страница 13: ...tions and connection specifications for the inverter Prior to connecting to the inverter check that each of the individual strings is de energised It is absolutely imperative that the inverter be connected to the public power supply network by a certified specialist ATTENTION High direct current voltage accrues even at low levels of radiation Never touch unprotected and cables that are in operatio...

Страница 14: ...on operation use or maintenance In addition no liability shall be borne for infringements of patent laws or other rights of third parties which result from the use of the modules unless mandated by law 9 Contact If you have any questions our WINAICO Team is available to assist you at all times WINAICO UK Ltd 7200 The Quorum Oxford Business Park North Oxford OX4 2JZ England Phone 44 0 1865 487149 F...

Страница 15: ......

Отзывы: