WIN Enterprises PL-80230 Скачать руководство пользователя страница 1

                  User’s Manual 

 

Custom Embedded Solutions 

WIN Enterprises, Inc.      [email protected]                                                      www-win-ent.com        (978)688-2000 

 

 

  1 

 

 

PL-80230 

 

 

 

Networking Appliance

 

 

1U Rack-mount Intel® Core

TM

 2 Quad Network Appliance with 

6 x GbE, SATA, CF, bypass function 

 

User’s Manual 

Version 1.0b, 312 

 

 

 

 

 

 

 

 

 

Содержание PL-80230

Страница 1: ...d Solutions WIN Enterprises Inc sales win ent com www win ent com 978 688 2000 1 PL 80230 Networking Appliance 1U Rack mount Intel CoreTM 2 Quad Network Appliance with 6 x GbE SATA CF bypass function User s Manual Version 1 0b 312 ...

Страница 2: ...A XT AT OS 2 and PS 2 are registered trademarks of International business Machine Corporation Award is a trademark of Award Software International Inc Intel is a trademark of Intel RTL is a trademark of Realtek VIA is a trademark of VIA Technologies Inc Microsoft Windows Windows NT and MS DOS are either trademarks or registered trademarks of Microsoft Corporation All other product names mentioned ...

Страница 3: ...odule with two GbE Copper and two GbE SFP 28 3 2 R120 Ethernet module with four GbE SFP 29 3 3 R121 Ethernet module with two GbE Copper or SFP 30 3 4 R122 Ethernet module with four GbE Copper 31 3 5 R127 Ethernet module with eight GbE Copper 32 3 6 R130 Ethernet module with eight GbE SFP 33 3 7 R137 Ethernet module with four GbE Copper 34 3 8 R117 Riser card for expansion module PCI E x8 35 3 9 R1...

Страница 4: ... win ent com www win ent com 978 688 2000 4 5 3 LAN Driver Installation 64 Appendix A Watchdog Timer Programming Guide 65 Appendix B LAN Bypass Programming Guide 68 Appendix C Programming the GPIO 82 Appendix D System Resources 84 Appendix E Cable Development Kit 89 ...

Страница 5: ...mini PCI socket and one PCI expansion slot The platform supports a range of from 6 GbE to a max of 14 GbE Ethernet ports from the front panel The front panel also has dual USB 2 0 ports one RJ 45 console port and LED indicators that monitor power and storage device activities for local system management maintenance and diagnostics In addition the PL 80230 is RoHS FCC and CE compliant 1 2 Specifica...

Страница 6: ...ad N A LED two Bypass LEDs Red one HDD LED Yellow one Power LED Green Dimension W x D x H 435mm W x 400mm D x 44mm H 17 1 W x 15 8 D x 1 7 H Operating Temperature Operating 0 40 C 32 104 F Mechanical and Environment Humidity 10 85 relative humidity non operating non condensing Weight 1pc CTN 7 5kgs 55 5cm W x 54cm D x 22 5cm H Certification CE FCC 1 3 Order Information We offer some accessories fo...

Страница 7: ... contents to make sure everything is intact Do not plug in the power adapter if you find the unit appears damaged Note Keep the PL 80230 in the original packaging until you start installation 1 5 Precautions Please make sure you properly ground yourself before handling the PL 80230 appliance or other system components Electrostatic discharge can easily damage the PL 80230 appliance Do not remove t...

Страница 8: ...om Embedded Solutions WIN Enterprises Inc sales win ent com www win ent com 978 688 2000 8 1 6 System Layout PL 80230 Front Side CF CPU DDR3 Socket Power supply HDD bay optional PCIe slot for Ethernet module Mini PCI PCI ...

Страница 9: ...User s Manual Custom Embedded Solutions WIN Enterprises Inc sales win ent com www win ent com 978 688 2000 9 1 7 Board Dimensions ...

Страница 10: ...User s Manual Custom Embedded Solutions WIN Enterprises Inc sales win ent com www win ent com 978 688 2000 10 Chapter 2 Connector Jumper Configuration 2 1 Connector Jumper Locations and Definitions ...

Страница 11: ...ctor CN7 Power Connector CN29 Giga LAN RJ45 Connector CN8 GPI Pin Header CN30 Giga LAN RJ45 Connector CN9 GPO Pin Header CN31 Giga LAN RJ45 Connector CN10 Parallel Box Header CN32 PCI E x8 Golden Finger CN11 LED Header by GPIO JP1 Power On Type Control CN12 SATA Connector JP2 Watchdog or Bypass Select CN13 SATA Connector JP3 CF Master Slave CN15 IDE 44Pin Connector JP4 GPI or H W Reset select CN16...

Страница 12: ...8 2000 12 2 2 Connector and Jumper Setting CN1 CN2 CN3 FAN Connector Pin Define 1 Ground 2 12V 3 Speed Detect CN4 12V Power Connector Pin Define 1 Ground 2 Ground 3 12V 4 12V CN5 ATX Power Connector Pin Define Pin Define 11 3 3V 1 3 3V 12 12V 2 3 3V 13 Ground 3 Ground 14 PS_ON 4 5V 15 Ground 5 Ground ...

Страница 13: ...000 13 16 Ground 6 5V 17 Ground 7 Ground 18 RSVD 8 POWER GOOD 19 5V 9 5VSB 20 5V 10 12V CN6 VGA Pin Header Pin Define Pin Define 1 RED 2 GREEN 3 BLUE 4 5V 5 Ground 6 Ground 7 Ground 8 Ground 9 5V 10 Ground 11 5V 12 SDA 13 HSYNC 14 VSYNC 15 SCL 16 NC CN7 Power Connector Pin Define 1 12V 2 GND 3 GND 4 VCC5 ...

Страница 14: ...IN Enterprises Inc sales win ent com www win ent com 978 688 2000 14 CN8 GPI Pin Header Pin Define 1 GPI0 2 GPI1 3 GPI2 4 GPI3 5 Ground CN9 GPO Pin Header Pin Define Pin Define 1 GPO4 2 GPO4 3 GPO5 4 GPO5 5 GPO6 6 GPO6 7 GPO7 8 GPO7 9 NC 10 NC ...

Страница 15: ...Parallel Box Header Pin Define Pin Define 1 STROBE 14 AUTOFD 2 PD0 15 ERR 3 PD1 16 INT 4 PD2 17 SLCTIN 5 PD3 18 Ground 6 PD4 19 Ground 7 PD5 20 Ground 8 PD6 21 Ground 9 PD7 22 Ground 10 ACK 23 Ground 11 BUSY 24 Ground 12 PE 25 Ground 13 SLCT 26 Ground CN11 LED header Programmable by GPIO Pin Define 1 GPIO24 2 GPIO25 ...

Страница 16: ... 13 SATA Connector Pin Define 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND CN15 IDE 44Pin Connector Pin Define Pin Define 1 RESET 23 PDIOW 2 GND 24 GND 3 PDD7 25 PDIOR 4 PDD8 26 GND 5 PDD6 27 PDIORDY 6 PDD9 28 PRI_PD1 7 PDD5 29 PDACK 8 PDD10 30 GND 9 PDD4 31 IDEIRQ 10 PDD11 32 NC 11 PDD3 33 PDA1 12 PDD12 34 IDE_CALID ...

Страница 17: ... 978 688 2000 17 13 PDD2 35 PDA0 14 PDD13 36 PDA2 15 PDD1 37 PCS1 16 PDD14 38 PCS3 17 PDD0 39 LED 18 PDD15 40 GND 19 GND 41 VCC5 20 NC 42 VCC5 21 PDDREQ 43 GND 22 GND 44 NC CN16 KB MS Pin Header Pin Define Pin Define 1 KCLK 2 MCLK 3 KDAT 4 MDAT 5 NC 6 NC 7 PS2_GND 8 PS2_GND 9 PS2_VCC 10 PS2_VCC ...

Страница 18: ...7 LPC Connector Pin Define Pin Define 1 3 3V 2 AD 0 3 AD 1 4 AD 2 5 AD 3 6 Frame 7 PCIERST 8 5V 9 CLOCK 10 PME 11 GND 12 13 SERIRQ 14 LDRQ CN18 SPI N C reserved for manufactory test Pin Define Pin Define 1 VCC3 2 GND 3 SPI_CS0 4 SPI_CLK 5 SPI_MISO 6 SPI_MOSI 7 NC 8 FLASH_IO CN19 PS_ON Short Power on Open Power off ...

Страница 19: ..._ RESUME A7 GND B7 GND A8 VCC3 B8 VCC3 A9 VCC3 B9 NC A10 VCC3 B10 VCC3_STBY A11 RESET B11 PE_WAKE A12 GND B12 LAN_PWRO K A13 PCI_E3_P2 B13 GND A14 PCI_E3_N2 B14 TX_0_DP A15 GND B15 TX_0_DN A16 RX_0_DP B16 GND A17 RX_0_DN B17 VCC5 A18 GND B18 GND A19 VCC5 B19 TX_1_DP A20 GND B20 TX_1_DN A21 RX_1_DP B21 GND A22 RX_1_DN B22 GND A23 GND B23 TX_2_DP A24 GND B24 TX_2_DN A25 RX_2_DP B25 GND A26 RX_2_DN B...

Страница 20: ...X_4_DN A35 RX_4_DP B35 GND A36 RX_4_DN B36 GND A37 GND B37 TX_5_DP A38 GND B38 TX_5_DN A39 RX_5_DP B39 GND A40 RX_5_DN B40 GND A41 GND B41 TX_6_DP A42 GND B42 TX_6_DN A43 RX_6_DP B43 GND A44 RX_6_DN B44 GND A45 GND B45 TX_7_DP A46 GND B46 TX_7_DN A47 RX_7_DP B47 GND A48 RX_7_DN B48 NC A49 GND B49 GND CN22 COM2 Box Header Pin Define Pin Define 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground...

Страница 21: ... win ent com www win ent com 978 688 2000 21 CN23 USB Pin Header Pin Define Pin Define 1 5V 2 5V 3 DATA 0 4 DATA 1 5 DATA 0 6 DATA 1 7 GND 8 GND 9 KEY PIN 10 GND CN24 USB0 1 Connector Pin Define 1 5VUSB0 2 USBDT0 3 USBDT0 4 Ground 5 5VUSB0 6 USBDT1 7 USBDT1 8 Ground ...

Страница 22: ...N25 COM1 RJ45 Connector Pin Define STD 1 CTS 2 DTR 3 TXD 4 GND 5 Ground 6 RXD 7 DSR 8 RTS CN26 CN27 CN28 CN29 CN30 CN31 Giga LAN RJ45 connector Pin Define 1 MDI0 2 MDI0 3 MDI1 4 MDI2 5 MDI2 6 MDI1 7 MDI3 8 MDI3 LED D2 Link Activity LED Link Green Activity Blinking D1 Bi Color Speed LED 10 Mbps Off 100 Mbps Green ...

Страница 23: ...VCC3 B6 SMB_DATA_ RESUME A7 VCC3 B7 GND A8 VCC3 B8 VCC3 A9 VCC3 B9 NC A10 VCC3 B10 VCC3_STBY A11 RESET B11 PE_WAKE A12 GND B12 LAN_PWRO K A13 PCI_E4_P1 B13 GND A14 PCI_E4_N1 B14 TX_0_DP A15 GND B15 TX_0_DN A16 RX_0_DP B16 GND A17 RX_0_DN B17 VCC5 A18 GND B18 GND A19 VCC5 B19 TX_1_DP A20 GND B20 TX_1_DN A21 RX_1_DP B21 GND A22 RX_1_DN B22 GND A23 GND B23 TX_2_DP A24 GND B24 TX_2_DN A25 RX_2_DP B25 ...

Страница 24: ...DN A35 RX_4_DP B35 GND A36 RX_4_DN B36 GND A37 GND B37 TX_5_DP A38 GND B38 TX_5_DN A39 RX_5_DP B39 GND A40 RX_5_DN B40 GND A41 GND B41 TX_6_DP A42 GND B42 TX_6_DN A43 RX_6_DP B43 GND A44 RX_6_DN B44 GND A45 GND B45 TX_7_DP A46 GND B46 TX_7_DN A47 RX_7_DP B47 GND A48 RX_7_DN B48 GPIO28 A49 PCIE_SLOT0 _1_SEL B49 GND JP1 Power On Type Control Pin Setting 1 2 Force on 2 3 Control by PS_ON JP2 Watchdog...

Страница 25: ... ent com www win ent com 978 688 2000 25 1 2 Bypass Mode 2 3 Watchdog JP3 CF Master Slave Short Master Open Slave JP4 GPI or H W Reset Select Pin Setting 1 2 GPI Mode 2 3 H W Reset Mode JP5 Clear CMOS Pin Setting 1 2 Hold Data Default 2 3 Clear CMOS JP6 LAN5 LAN6 Bypass ...

Страница 26: ... Pin Setting 1 2 Normal Default 2 3 Bypass to disable when power on JP7 LAN3 LAN4 Bypass Pin Setting 1 2 Normal Default 2 3 Bypass to disable when power on SW1 GPI or H W Reset Button LED1 Front LEDs Pin Define Pin Define 1 GND 2 Power_LED 3 HDD LED 4 HDD LED 5 BYPASS LED 6 BYPASS_LED 7 BYPASS LED 8 BYPASS_LED ...

Страница 27: ...or it means they contain no moving parts Thus it provides users with much greater protection of the data than conventional magnetic disk device Pin Assignment Pin Assignment Pin Assignment Pin Assignment Pin Assignment 1 Ground 11 Ground 21 D00 31 D15 41 RESET 2 D03 12 Ground 22 D01 32 CS 42 ORDY 3 D04 13 VCC 23 D02 33 NC 43 DREG 4 D05 14 Ground 24 WP 34 IOR 44 DACK 5 D06 15 Ground 25 NC 35 IOW 45...

Страница 28: ...dule combinations to match various applications and market demands 3 1 R119 Ethernet module with two GbE Copper and two GbE SFP R119A is a two GbE Copper and two GbE SFP Ethernet module The golden edge fingers to be connected with CN20 proprietary connector of PL 80230 board 2 x GbE Copper ports 2 x GbE SFP ports Golden Edge Fingers to be connected with CN20 of MB 80230 or PCI E x8 slot of R117A ...

Страница 29: ...om 978 688 2000 29 3 2 R120 Ethernet module with four GbE SFP R120A is a four GbE SFP Ethernet module The golden edge fingers to be connected with CN12 proprietary connector of PL 80230 board 4 x GbE SFP ports Golden Edge Fingers to be connected with CN20 of MB 80230 or PCI E x8 slot of R117A ...

Страница 30: ... pair bypass function for optional ODM project The golden edge fingers must be connected with CN20 proprietary connector of CB 7974 board The alternative R121A is a two GbE SFP Ethernet module Picture 1 R121A Picture 2 R121B 2 x GbE SFP ports Golden Edge Fingers to be connected with CN20 of MB 80230 or PCI E x8 slot of R117A Golden Edge Fingers to be connected with CN20 of MB 80230 or PCI E x8 slo...

Страница 31: ...8 688 2000 31 3 4 R122 Ethernet module with four GbE Copper R122A is a four GbE Copper Ethernet module The golden edge fingers to be connected with CN20 proprietary connector of PL 80230 board Golden Edge Fingers to be connected with CN20 of MB 80230 or PCI E x8 slot of R117A 4 x GbE Copper ports ...

Страница 32: ...in ent com 978 688 2000 32 3 5 R127 Ethernet module with eight GbE Copper R127A is a four GbE Copper Ethernet module The golden edge fingers to be connected with CN20 proprietary connector of PL 80230 board Golden Edge Fingers to be connected with CN20 of MB 80230 8 x GbE Copper ports ...

Страница 33: ...w win ent com 978 688 2000 33 3 6 R130 Ethernet module with eight GbE SFP R130A is a four GbE Copper Ethernet module The golden edge fingers to be connected with CN20 proprietary connector of PL 80230 board Golden Edge Fingers to be connected with CN20 of MB 80230 8 x GbE SFP ports ...

Страница 34: ...module with four GbE Copper R137A is a four GbE Copper module and designed reserved one pair bypass function for optional ODM project The golden edge fingers must be connected with CN20 proprietary connector of PL 80230 board Golden Edge Fingers to be connected with CN20 of MB 80230 or PCI E x8 slot of R117A 4 x GbE Copper ports ...

Страница 35: ...be connected to CN32 PCI E x8 Golden Finger of PL 80230 appliance 3 9 R118 Riser card for PCI E x8 add on card R118A is one PCI E x8 to PCI E x8 riser card for standard PCI E x8 x4 x1 add on card It must be connected to CN32 PCI E x8 Golden Finger of PL 80230 appliance PCI E x8 slot to proprietary Ethernet module PCI E x8 slot to be Golden Edge Fingers of MB 80230 PCI E x8 slot to standard Add on ...

Страница 36: ...up program is required CMOS RAM stores information for Date and time Memory capacity of the appliance Type of display adapter installed Number and type of disk drives The CMOS memory is maintained by battery installed on the PL 80230 board By using the battery all memory in CMOS can be retained when the system power switch is turned off The system BIOS also supports easy way to reload the CMOS dat...

Страница 37: ...other disk drive Use your system after not having used it for a long time Find the original setup missing Replace the battery Change to a different type of CPU Run the AMI Flash program to update the system BIOS Run the CMOS Setup program after you turn on the system On screen instructions explain how to use the program Enter the CMOS Setup program s main menu as follows 1 Turn on or reboot the sy...

Страница 38: ...ation Processor Displays the auto detected CPU specification System Memory Displays the auto detected system memory SystemTime hour min sec This item allows you to set the system time System Date Day mm dd yyyy This item allows you to set the system date In the main menu press F10 Save Changes and Exit to save your changes and reboot the system Choosing Discard Changes and Exit ignores your change...

Страница 39: ...cribed in the following and the following sections of this chapter Main For changing the basic system configurations Advanced For changing the advanced system settings Boot For changing the system boot configurations Security Use this menu to set User and Supervisor Passwords Chipset For changing the chipset settings Exit For selecting the exit options and loading default settings ...

Страница 40: ...s for the CPU and other system devices Use the Advanced Setup option as follows 1 Choose Advanced from the main menu The following screen appears 2 Use the arrow keys to move between fields Modify the selected field using the PgUP PgDN keys Some fields let you enter numeric values directly 3 After you have finished with the Advanced setup press the ESC key to return to the main menu ...

Страница 41: ... automatically detected by BIOS Intel R Virtualization Tech Enabled This item allows you to enable or disable the Intel Virtualization Tech Execute Disable Bit capability Enabled Intel s Execute Disable Bit is a hardware based security feature that can reduce exposure to viruses and malicious code attacks and prevent harmful software from executing and propagating on the server or network ...

Страница 42: ... Enhanced This item allows you to configure the SATA Configure SATA as IDE Configure SATA Channels Before PATA Primary Secondary Third IDE Master This information is auto detected by BIOS and is not user configurable It will show Not Detected if no IDE device is installed in the system Primary Secondary Third IDE Slaver This information is auto detected by BIOS and is not user configurable It will...

Страница 43: ...etting to Auto enables the LBA mode if the device supports this mode and if the device was not previously formatted with LBA mode disabled Block Multi Sector Transfer Auto Enables or disables the Block Multi Sectors Transfer When set to Auto the data transfer from and to the device occurs multiple sectors at a time if the device supports multi sector transfer feature When set to Disabled the data ...

Страница 44: ...ing Analysis and Reporting Technology It allows system to use the SMART protocol to monitor your hard disk status 32Bit Data Transfer Enabled Enables or disables 32 bit data transfer If the host controller does not support 32 bit data transfer this menu must be set to Disabled 4 4 3 Super IO Configuration Parallel Port Address 378 Selects the Parallel Port base addresses Parallel Port Mode Normal ...

Страница 45: ...00 45 Selects the Parallel Port mode Parallel Port IRQ IRQ7 Selects the Parallel Port IRQ 4 4 4 Hardware Health Configuration This screen shows you the CPU core voltage System voltage System temperature and CPU temperature 4 4 5 ACPI Configuration This sub menu is used to change the settings for the ACPI ...

Страница 46: ...terprises Inc sales win ent com www win ent com 978 688 2000 46 ACPI Aware O S Enables or disables ACPI support for Operating System Chipset ACPI Configuration This sub menu configures the south bridge ACPI configuration It contains below sub menus ...

Страница 47: ...User s Manual Custom Embedded Solutions WIN Enterprises Inc sales win ent com www win ent com 978 688 2000 47 ...

Страница 48: ...mber COM1 This item allows you to select the serial port for console redirection Make sure the selected port is enabled Base Address IRQ 3F8h 4 Serial Port Mode 115200 8 n 1 This item allows you to select serial port settings Flow Control None This item allows you to select flow control for console redirection Redirection After BIOS POST Disabled This item allows you to set Redirection configurati...

Страница 49: ...ST Terminal Type ANSI This item allows you to select the target terminal type VT UTF8 Combo Key Support Enabled This item allows you to enable or disable VT UTF8 combination key support for ANSI VT100 terminals Sredir Memory Display Delay No Delay This item allows you to set the delay in seconds to display memory information 4 4 7 Trusted Computing This sub menu allows you to set or change the con...

Страница 50: ...es Legacy USB Support Enabled Enables support for legacy USB AUTO option disables legacy support if no USB devices are connected Port 64 60 Emulation Disabled This item allows you to enable emulation of I O ports 64h and 60h so that there is full PS 2 legacy support for USB keyboards and mice It is also useful in providing USB keyboard and mouse support in Windows NT which does not natively suppor...

Страница 51: ...User s Manual Custom Embedded Solutions WIN Enterprises Inc sales win ent com www win ent com 978 688 2000 51 sub menus ...

Страница 52: ...tup option as follows 1 Choose Boot from the main menu The following screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields using the PnUP PgDN Keys For information on the various options press F1 key 3 After you have finished with the Boot setup press the ESC key to return to the main menu ...

Страница 53: ...re system boot setting with below sub menus Quick Boot Enabled This item allows BIOS to skip certain tests POST Power On Self Tests while booting This will decrease the time needed to boot the system Hit DEL Message Display Enabled Displays Press DEL to run Setup in POST Onboard Lan Boot ROM Disabled This item allows you to enable or disable the Onboard Lan Boot function ...

Страница 54: ... com www win ent com 978 688 2000 54 4 5 2 Boot Device Priority 1st Boot Device USB Generic This item allows you to set the boot priority Specifies the boot sequence from the available devices A device enclosed in parenthesis has been disabled in the corresponding type menu ...

Страница 55: ...tom Embedded Solutions WIN Enterprises Inc sales win ent com www win ent com 978 688 2000 55 4 5 3 Hard Disk Drives 1st 2nd 3rd 4th Drive USB Generic This item is used to specify the boot sequence from available devices ...

Страница 56: ...ted fields using the PgUP PgDN keys Please press the F1 key for information on the various options 3 After you have finished with the Security setup press the ESC key to return to the main menu Change Supervisor Password This item allows you to set or change the supervisor password The Supervisor Password item on top of the screen shows the default Not Installed After you have set a password this ...

Страница 57: ...ve set a password this item shows Installed Clear User Password This item allows you to clear the user password Boot Sector Virus Protection Disabled This item allows you to enable or disable the boot sector virus protection If enabled AMI BIOS will issue a warning when a virus or program attempts to write to the hard disk s boot sector or attempts to execute disk format command ...

Страница 58: ... Setup option as follows 1 Choose Chipset from the main menu The following screen appears 2 Move between items and select values by using the arrow keys Modify the selected field the PgUP PgDN keys For information on the various options press F1 key 3 After you have finished with the Chipset Setup press the ESC key to return to the main menu ...

Страница 59: ...f overlapped PCI memory above the total physical memory Disabled Do not allow remapping of memory DRAM Frequency Auto This item allows you to configure the clock frequency of the installed DRAM If Auto is selected the BIOS will detect the memory modules installed and assigns appropriate frequency automatically Memory Hole Disabled This item allows you to enable or disable the memory hole Initate G...

Страница 60: ...n AC Power Loss Last State This item allows you to set the power state after an unexpected AC Power loss If Power Off is selected the AC Power remains off when the power recovers If Power On is selected the AC Power resumes and the system starts to boot up when the power recovers Power Off LAN bypass1 bypass2 Disabled This item allows you to enable or disable the LAN bypass function when Power Off...

Страница 61: ...aults for the BIOS items Use the Exit option as follows 1 Choose Exit from the main menu the following screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields using the PgUP PgDN keys For information on the various options please press F1 key 3 Please press the ESC key to return the main menu after finishing with the Exit Options Save Changes and Ex...

Страница 62: ...reviously saved values F7 key can be used for this operation Load Optimal Defaults This item allows you to load optimal defaults for each of the parameters on the Setup menus which will provide the best performance settings for your system F9 key can be used for this operation Load Failsafe Defaults This item allows you to load failsafe defaults for each of the parameters on the Setup menus which ...

Страница 63: ...indows and Linux operation system as follows Before installation please check your OS version If your OS is not in the following list please upgrade your OS version OS Version Windows Windows Vista x64 Windows Server 2003 Windows Server 2008 Windows XP SP2 Windows XP SP3 Windows 7 Linux Unix Like Fedora 9 x64 2 6 25 Redhat Enterprise 5 0 x64 Version 5 2 2 6 18 Redhat Enterprise 5 0 x64 Version 5 3...

Страница 64: ...n the setup CD Please install the driver following the procedures 5 3 LAN Driver Installation PL 80230 offers the LAN driver in the setup CD Please click the Autorun file and install the driver following the procedures 1 Insert the setup CD of PL 80230 into your CD ROM drive 2 Choose the Drivers file to click the Autorun icon 3 Follow the procedures to finish the installation ...

Страница 65: ... 1 Programming the Watchdog Timer The WIN ENTERPRISES PL 80230 provides a watchdog timer that can reset the system or activate LAN bypass function It provides the following function for user programming Can be enabled and disabled by user s program Timer can be set from 1 to 255 seconds or 1 to 255 minutes Generates a KBRST P60 or activate WDTO P77 signal if the software fails to reset the timer w...

Страница 66: ...W Select WDTO count mode 0 Second Mode 1 Minute Mode CRF5 Bit 1 R W Enable Disable the WDTO output low pulse to KBRST 0 Disable 1 Enable CRF6 R W Watchdog time out value 0 stop timer default 01 FFh Writing a non zero value to this register causes the counter to load the value to watchdog counter and start counting down The amount of the count in seconds or minutes depends on the value set in regis...

Страница 67: ...r the extended function mode interruptible double write MOV DX 2EH Unlock W83627EHG MOV AL 87H OUT DX AL OUT DX AL Configure logical device 8 MOV AL 07H OUT DX AL Point to Logical Device Number Reg INC DX MOV AL 08H OUT DX AL Select logical device 8 Set second as counting unit and KBRST time out event DEC DX MOV AL F5H OUT DX AL Select CRF5 INC DX IN AL DX AND AL F5H Set Watchdog time our to secon...

Страница 68: ...2 Enable watchdog timer and set 2 minutes as timeout interval and set WDTO signal as the time out event to control LAN by pass or activate hardware reset through JP2 Please refer to jumper setting section for more detail information Enter the extended function mode interruptible double write MOV DX 2EH Unlock W83627EHG MOV AL 87H OUT DX AL OUT DX AL Configure logical device 8 MOV AL 07H OUT DX AL ...

Страница 69: ...ting unit DEC DX MOV AL F5H OUT DX AL Select CRF5 INC DX MOV AL 08H OUT DX AL Set Watchdog time our to minute mode Load 2 minutes to Watchdog Counter and start counting down DEC DX MOV AL F6H OUT DX AL Select CRF6 INC DX MOV AL 02H OUT DX AL Time out occurs after 2 minutes Exit extended function mode DEC DX MOV AL AAH OUT DX AL ...

Страница 70: ...s settings in BIOS setup Power off LAN Bypass1 Enable Disable Power on LAN Bypass1 Enable Disable Power off LAN Bypass2 Enable Disable Power on LAN Bypass2 Enable Disable Note You must set Power off LAN Bypass1 to Enable to get the Power on LAN Bypass1 setup item and set Power off LAN Bypass2 to Enable to get the Power on LAN Bypass2 setup item There are three behaviors of the LAN Bypass function ...

Страница 71: ...ions WIN Enterprises Inc sales win ent com www win ent com 978 688 2000 71 and Power on off LAN Bypass2 settings control LAN ports on CN28 CN29 Segment 2 Each segment is controllable through GPIO pins Bypass Behavior A Bypass Behavior B ...

Страница 72: ...er time out 2 Refer to watchdog timer section to set timer interval value and enable watchdog timer Note Once the watchdog timer time out you need to restart the system to reset the timer 3 How to control Segment 1 2 LAN bypass function by GPIO during power on state The bypass function can be enabled or disabled through ICH GPIO38 GPIO39 during power on state Below is the I O port address and cont...

Страница 73: ... Bit 6 0 Set segment 1 bypass to disable when power on 1 Set segment 1 bypass to enable when power on Please follow below steps to set the LAN bypass function control by GPIO 1 Setup JP6 to 1 2 to enable bypass segment 1 function control by GPIO38 2 Setup JP7 to 1 2 to enable bypass segment 2 function control by GPIO39 3 Refer to below program code and set segment 1 2 LAN ports to bypass state or ...

Страница 74: ... 0 OUT DX AL send value Bypass Enabled Behavior B MOV DX 4B8H address IN AX DX read value AND AL 0BFH mask bit 6 OR AL 40H set bit 6 1 OUT DX AL send value Segment 2 Control by GPIO 39 Normal state Behavior A MOV DX 4B8H address IN AX DX read value AND AL 07FH mask bit 7 OR AL 00H set bit 7 0 OUT DX AL send value Bypass Enabled Behavior B MOV DX 4B8H address IN AX DX read value AND AL 07FH mask bi...

Страница 75: ...it 2 Bit 1 Bit 0 X X X X R W R W R W R W R W Read Write X Not used Bit 1 0 01 Set segment 1 bypass to enable when power off 10 Set segment 1 bypass to disable when power off Bit 3 2 01 Set segment 2 bypass to enable when power off 10 Set segment 2 bypass to disable when power off Refer to below program code and set segment 1 2 LAN ports to bypass state or disable when power is off Segment 1 Contro...

Страница 76: ...le bypass circuit MOV DX 2EH MOV AL 0F1H OUT DX AL O 2E F1 MOV DX 2FH IN AL DX read F1 AND AL 0FCH mask bit 1 bit 0 OR AL 02H set bit 1 1 bit 0 0 OUT DX AL send value Exit extended function mode MOV DX 2EH MOV AL 0AAH OUT DX AL close super IO Bypass enabled when power off Enter the extended function mode interruptible double write MOV DX 87H address MOV AL 2EH Index OUT DX AL enter super IO OUT DX...

Страница 77: ...MOV DX 2EH MOV AL 0F1H OUT DX AL O 2E F1 MOV DX 2FH IN AL DX read F1 AND AL 0FCH mask bit 1 bit 0 OR AL 01H set bit 1 0 bit 0 1 OUT DX AL send value Exit extended function mode MOV DX 2EH MOV AL 0AAH OUT DX AL close super IO Segment 2 Control by CRF1 bit 3 2 Bypass disabled when power off Enter the extended function mode interruptible double write MOV DX 87H address MOV AL 2EH Index OUT DX AL ente...

Страница 78: ...le bypass circuit MOV DX 2EH MOV AL 0F1H OUT DX AL O 2E F1 MOV DX 2FH IN AL DX read F1 AND AL 0F3H mask bit 3 bit 2 OR AL 08H set bit 3 1 bit 2 0 OUT DX AL send value Exit extended function mode MOV DX 2EH MOV AL 0AAH OUT DX AL close super IO Bypass enabled when power off Enter the extended function mode interruptible double write MOV DX 87H address MOV AL 2EH Index OUT DX AL enter super IO OUT DX...

Страница 79: ...V DX 2FH MOV AL 09H OUT DX AL O 2F 09 select logic device 9 Read CRF1 and set bit 3 0 bit 2 1 to enable bypass circuit MOV DX 2EH MOV AL 0F1H OUT DX AL O 2E F1 MOV DX 2FH IN AL DX read F1 AND AL 0F3H mask bit 3 bit 2 OR AL 04H set bit3 0 bit 2 1 OUT DX AL send value Exit extended function mode MOV DX 2EH MOV AL 0AAH OUT DX AL close super IO ...

Страница 80: ...e to BIOS setup setting please add below sample code to the end of previous section program MOV DX 72H MOV AL 29H OUT DX AL MOV DX 73H MOV AL value OUT DX AL D disable E enable ON power on bypass status OFF power off bypass status For example Power off LAN Segment 1 bypass Enable Power on LAN Segment 1 bypass Disable Power off LAN Segment 2 bypass Enable Power on LAN Segment 2 bypass Enable Sample...

Страница 81: ... ON State Bypass Control Status Register I O Address 4B8H Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 W W X X X X W X W Write X Not used Bit 1 1 Set segment 1 bypass to disable when power on 0 Set segment 1 bypass to enable when power on Segment 1 Control by GPIO 33 Normal state Behavior A MOV DX 4B8H address IN AX DX read value AND AL 0FDH mask bit 1 OR AL 02H set bit 1 1 OUT DX AL send value...

Страница 82: ... GPI 0 Programming of the GPI 0 LOW 1 HIGH GPI 3 GPI 2 GPI 1 GPI 0 Data Bit 3 Bit 2 Bit 1 Bit 0 0 0 0 0 x0 0 0 0 1 x1 0 0 1 0 x2 0 0 1 1 x3 0 1 0 0 x4 0 1 0 1 x5 0 1 1 0 x6 0 1 1 1 x7 1 0 0 0 x8 1 0 0 1 x9 1 0 1 0 xA 1 0 1 1 xB 1 1 0 0 xC 1 1 0 1 xD 1 1 1 0 xE 1 1 1 1 xF Note x is the reserved data Programming of the GPO 0 LOW 1 HIGH GPO 7 GPO 6 GPO 5 GPO 4 Data Bit 7 Bit 6 Bit 5 Bit 4 0 0 0 0 0x ...

Страница 83: ... 0 Ex 1 1 1 1 Fx Note x is the reserved data DOS DEBUG Program 1 Initializing the GPIO O 2E 87 O 2E 87 O 2E 29 configuration register CR29 O 2F 01 set GPIO not GAME PORT O 2E 07 point to logical device number reg O 2F 07 select logical device 7 O 2E 30 configuration register CR30 O 2F 01 open logical device control O 2E F0 configuration register CRf0 O 2F 0F 00001111 0 ouput 1 input Program 2 Prog...

Страница 84: ...to use extra add on cards be sure that the IRQs do not conflict Any remaining IRQs then may be assigned to this PCI Bus You are able to use Microsoft s Diagnostic MDS EXE utility included in Windows directory to see their map IRQ Assignment IRQ0 Timer IRQ1 Keyboard IRQ2 Interrupt rerouting from IRQ8 through IRQ15 IRQ3 COM2 IRQ4 COM1 IRQ5 PCI PCI Bridge IRQ6 PCI PCI Bridge IRQ7 LPT1 IRQ8 RTC IRQ9 I...

Страница 85: ...Free DMA1 ISA Free DMA2 ISA Free DMA3 ISA Free DMA4 AT DMA controller Cascade DMA5 ISA Free DMA6 ISA Free DMA7 ISA Free Memory Map The following table indicates memory of PL 80230 The address ranges specify the runtime code length Memory below 1MB 1MB 640KB Address Range Type Owner A0000 AFFFF ISA VGA Adapter B0000 BFFFF ISA VGA Adapter C0000 CC3FF ISA Adapter ROM E0000 EFFFF ISA Mapped RAM F0000 ...

Страница 86: ...000000 3DE00000 00000000 02200000 Reserved 00000000 FEE00000 00000000 00001000 Reserved 00000000 FFE00000 00000000 00200000 Reserved I O Map The addresses shown in the table are typical locations I O Port Assignment 0 F AT DMA controller 20 21 AT interrupt controller 2E 2F Motherboard Resource 40 43 8254 Compatible Programmable Timer Address Range Type Owner D0000000 DFFFFFF3 PCI VGA Adapter FDFFB...

Страница 87: ...378 37F LPT1 3B0 3BB VGA Adapter 3C0 3DF VGA Adapter 3F8 3FF COM1 400 41E SMBus Controller 480 4BF Motherboard Resource 4D0 4D1 Motherboard Resource 800 87F Motherboard Resource 8F0 8FF Motherboard Resource A00 A0F Motherboard Resource A10 A1F Motherboard Resource CF8 CFF Motherboard Resource 6800 680E IDE Controller 6880 6882 IDE Controller 6C00 6C06 IDE Controller 7000 7002 IDE Controller 7080 7...

Страница 88: ... Solutions WIN Enterprises Inc sales win ent com www win ent com 978 688 2000 88 A000 AFFF PCI PCI Bridge B000 BFFF PCI PCI Bridge C000 CFFF PCI PCI Bridge D000 DFFF PCI PCI Bridge E000 EFFF PCI PCI Bridge FFA0 FFAE IDE Controller ...

Страница 89: ...tem Description Part No Qty Ethernet Cat 5 Cable 2M RoHS CB EC5200 00 1 Cross Over 2M Color RoHS CB CO5202 4 00 1 RJ45 to DB9 2M Cable RoHS CB RJDB91 00 1 2m null modem cable RoHS CB DB9200 01 1 VGA CABLE 2mm 15CM RoHS CB IVGA01 00 1 KB MS CABLE 15CM RoHS CB IPS200 00 1 USB CABLE w Bracket RoHS CB IUSB01 00 1 CB EC5200 00 CB CO5202 4 00 CB RJDB91 00 CB DB9200 00 CB IVGA01 00 CB IPS200 00 CB IUSB01...

Отзывы: