WIN Enterprises PL-10590 Скачать руководство пользователя страница 1

 

WIN Enterprises, Inc.,    PH:978-688-2000    Email: [email protected] 

           

 

PL-10590   

Networking Appliance 

User’s Manual 

Version 1.0

 

 

 

2U Rackmounted Dual Intel® Haswell-EP Xeon E5-2600V3 Series Processor 

and C612 PCH Network System, 3 PCIe x16 slot for expansion LAN module, 

IPMI, 1 USB, 4 SATA HDD, 2 GbE, CF, 2 PCIe x8 slot, Redundant PSU 

 

 

 

 

 

 

         

 

 

 

 

 

 

 

 

 

 

 

Содержание PL-10590

Страница 1: ...om PL 10590 Networking Appliance User s Manual Version 1 0 2U Rackmounted Dual Intel Haswell EP Xeon E5 2600V3 Series Processor and C612 PCH Network System 3 PCIe x16 slot for expansion LAN module IPM...

Страница 2: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com Revision History Date Version Modification Editor 2015 01 07 1 0 First Release Denny Huang...

Страница 3: ...f International business Machine Corporation Award is a trademark of Award Software International Inc Intel is a trademark of Intel RTL is a trademark of Realtek VIA is a trademark of VIA Technologies...

Страница 4: ...d Add on card 3 1 R323 Ethernet module with four GbE copper and four GbE fiber 3 2 R324 Ethernet module with eight GbE fiber 3 3 R325 Ethernet module with eight GbE copper 3 4 R319 Front I O module 3...

Страница 5: ...000 Email sales win ent com Chapter 5 Utility Driver Installation 5 1 Operation System Supporting 5 2 System Driver Installation 5 3 LAN Driver Installation Appendix Appendix A Linux DOS Sample code A...

Страница 6: ...80 PCIe lanes Each E5 2600V3 processor support four DDR4 memory up to 2133 MHz and maximum memory capacity is up to 128 GB In addition PL 10590 supports four 3 5 SATA hard disks or solid state drives...

Страница 7: ...e with 2 SFP 10GbE ports Intel82599ES w o re driver R333A Expansion module with 2 QSFP ports Intel XL710 R316A Expansion module with 2 SFP 10GbE ports Intel82599ES with non latching bypass R316B Expan...

Страница 8: ...d Environment Humidity 10 85 relative humidity non operating non condensing Weight 1pc CTN 20 kgs Certification CE FCC 1 3 Ordering Information PL 10590A A 2U Rack Mount Intel Haswell EP with C612 PCH...

Страница 9: ...5 cable 2M CB IPS200 00 KBMS cable 15CM CB IUSB2B 00 USB cable 25CM CB IVGA01 00 VGA cable 20CM CB RJDB91 00 RJ 45 to DB 9 cable 2M 1 4 Packaging Please make sure that the following items have been in...

Страница 10: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com Note Keep the PL 10590 in the original packaging until you start installation...

Страница 11: ...can be easily damage the PL 10590 appliance Do not remove the anti static packing until you are ready to install the PL 10590 appliance Ground yourself before removing any system component from its p...

Страница 12: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com 1 6 System Layout Front panel features Rear panel features...

Страница 13: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com 1 7 Dimensions 1 8 PCIe configuration for LAN module by CPU0 CPU1...

Страница 14: ...s win ent com Chapter 2 Connector Jumper Configuration MB 1059A Rev A1 Connector Pin Defined and Jumper Settings Connector List Connector Description CN1 VR12 5 SMBus Header CN2 POWER Button Connector...

Страница 15: ...A3 0 Connector CN17 COM Port 2 CN18 LPC Port CN19 PS 2 KB MS Connector CN20 IO Connector To R319 CN21 SATA3 0 Connector CN22 VGA Connector CN23 LCM Backlight Connector CN24 LPT Port CN25 SATA3 0 Conne...

Страница 16: ...CN3 CN5 CN8 2x4 12V Power Connector PIN Description PIN Description 1 GND 2 GND 3 GND 4 GND 5 12V 6 12V 7 12V 8 12V CN7 CPLD Programming Header PIN Description PIN Description 1 TCK 2 GND 3 TDO 4 3 3V...

Страница 17: ...GPI5 3 GPI6 4 GPI7 5 GND CN17 COM2 RS 232 Connector PIN Description PIN Description 1 DCD 2 2 DSR 2 3 RXD 2 4 RTS 2 5 TXD 2 6 CTS 2 7 DTR 2 8 RI 2 9 GND 10 NC CN18 LPC Connector PIN Description PIN D...

Страница 18: ...LAN2_ACT 12 LAN1_CON_C 13 3 3V 14 LAN1_CON_D 15 RTS 1 CTS 1 16 LAN1_CON_D 17 DTR 1 18 GND 19 TXD 1 20 LAN2_CON_A 21 RXD 1 22 LAN2_CON_A 23 DSR 1 24 LAN2_CON_B 25 GPO70 26 LAN2_CON_B 27 GPO71 28 LAN2_C...

Страница 19: ...PIN Description PIN Description 1 STB 14 AFD 2 PDR0 15 ERR 3 PDR1 16 PAR_INIT 4 PDR2 17 SLIN 5 PDR3 18 GND 6 PDR4 19 GND 7 PDR5 20 GND 8 PDR6 21 GND 9 PDR7 22 GND 10 ACK 23 GND 11 BUSY 24 GND 12 PE 2...

Страница 20: ...sales win ent com Jumper List JP1 Clear CMOS 1 2 Normal 2 3 Clear CMOS JP2 1 2 PCI e 2 3 NCSI JP3 AT ATX Select 1 2 ATX 2 3 AT JP4 GPIO For Debug JP5 WDT FOR LAN BY PASS OR RESET 1 2 RESET 2 3 BYPASS...

Страница 21: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com Chapter 3 Optional LAN Module Add on Card Setting 3 1 R323 Ethernet module with four GbE copper and four GbE fiber...

Страница 22: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com 3 2 R324 Ethernet module with eight GbE fiber 3 3 R325 Ethernet module with eight GbE copper...

Страница 23: ...Inc PH 978 688 2000 Email sales win ent com 3 4 R319 Front I O module R319A is a front I O module with GPO LEDs one USB 2 0 port one RJ45 console port COM1 RS 232 two GbE port The CN1 must be connect...

Страница 24: ...N Enterprises Inc PH 978 688 2000 Email sales win ent com 3 5 R316 Expansion module with 2 SFP 10GbE ports with Bypass R316A Expansion module with 2 SFP 10GbE ports Intel82599ES with non latching bypa...

Страница 25: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com R316B Expansion module with 2 SFP 10GbE ports Intel82599ES with latching bypass...

Страница 26: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com 3 6 R258B Expansion module with 4 RJ45 10G ports Intel X540 BT2 3 7 R333A Expansion module with 2QSFP ports Intel XL710...

Страница 27: ...d programs that provide the device level control for the major I O devices in the system It contains a set of routines called POST for Power On Self Test that check out the system when you turn it on...

Страница 28: ...IOS setup program to modify the system parameters to reflect the options installed in your system and to customize your system For example you should run the Setup program after you Received an error...

Страница 29: ...lays the total memory size System Language Change the language display in BIOS setup utility System Date Day mm dd yyyy This item allows you to set the system date SystemTime hour min sec This item al...

Страница 30: ...his chapter Main For changing the basic system configurations Advanced For changing the advanced system settings IntelRCSetup For customize the Intel chipset function Server Mgmt For changing the Serv...

Страница 31: ...the Advanced Setup option as follows 1 Choose Advanced from the main menu The following screen appears 2 Use the arrow keys to move between fields Modify the selected field using the PgUP PgDN keys So...

Страница 32: ...rises Inc PH 978 688 2000 Email sales win ent com ACPI Settings Enable ACPI Auto Configuration Enables or Disables BIOS ACPI Auto Configuration Lock Legacy Resources Enables or Disables Lock of Legacy...

Страница 33: ...688 2000 Email sales win ent com Platform Function Watch dog Mode Watch dog Mode Sec Min Watch dog Timer Watch dog Mode Sec Min SOL Switch Switch console for COM2 or SOL W83793 Mode If Switch this fun...

Страница 34: ...Email sales win ent com NCT6791D Super IO Configuration Serial Port 1 Configuration Set Parameters of Serial Port 1 Serial Port 2 Configuration Set Parameters of Serial Port 2 Parallel Port Configurat...

Страница 35: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com Serial Port Enables or Disables Serial Port Change Setting Device Settings NCT6791D Hardware Monitor...

Страница 36: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com Serial Port Console Redirection...

Страница 37: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com COM0 COM1 Console Redirection Console Redirection Enable or Disable Terminal Type...

Страница 38: ...always 0 Mark and Space Parity do not allow for error detection They can be used as an additional data bit Stop Bits Stop bits indicate the end of a serial data packet A start bit indicates the begin...

Страница 39: ...Redirection After BIOS POST The Settings specify if BootLoader is selected than Legacy console redirection is disabled before booting to Legacy OS Default value is Always Enable which means Legacy co...

Страница 40: ...ield as a requester No Snoop No Snoop Enable Disable for each CB device Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value Extended Synch If ENABLED all...

Страница 41: ...s On non PCI Express aware OS s Pre Windows Vista some devices may not be correctly reinitialized after S3 Enabling this restores PCI Express device configurations on S3 resume Warning Enabling this m...

Страница 42: ...mand Register Set AtomicOp Egress Blocking If supported by hardware and set to Enabled outbound AtomicOp Requests via Egress Ports will be blocked IDO Request Enable If supported by hardware and set t...

Страница 43: ...l force LTSSM to send SKP Ordered Sets between sequences when sending Compliance Pattern or Modified Compliance Pattern Hardware Autonomous Width If supported by hardware and set to Disabled this will...

Страница 44: ...Support GateA20 Active UPON REQUEST GA20 can be disabled using BIOS services ALWAYS do not allow disabling GA20 this option is useful when any RT code is executed above 1MB Option ROM Messages Set dis...

Страница 45: ...off This is a workaround for OSes without EHCI hand off support The EHCI ownership change should be claimed by EHCI driver Mass Storage Driver Support Enable Disable USB Mass Storage Driver Support Po...

Страница 46: ...properly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor USB Precondition Precondition work on USB host...

Страница 47: ...on 1066 Displays and provides option to change the Power Management Settings Common RefCode Configuration Displays and provides option to change the Common RefCode Settings Memory Configuration Displa...

Страница 48: ...bled core is enabled Execute Disable Bit XD can prevent certain classes of malicious buffer overflow attacks when combined with a supporting OS Windows Server 2003 SP1 Windows XP SP2 SuSE Linux 9 2 Re...

Страница 49: ...le the Mid Level Cache L2 prefetching of adjacent cache lines DCU Streamer Prefetcher Enable prefetch of next L1 Data line based upon multiple loads in same cache line DCU IP Prefetcher Enable prefetc...

Страница 50: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com CPU P State Control Controls CPU frequency...

Страница 51: ...OS sets CPU frequency according load When disabled CPU frequency is set at max non turbo Turbo Mode Turbo mode allows a CPU logical processor to execute a higher frequency when enough power is availab...

Страница 52: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com Memory Frequency Maximum Memory Frequency Selections in Mhz Do not select Reserved...

Страница 53: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com IIO 0 1 Configuration Displays and provides the option to change the IIO Settings...

Страница 54: ...n Isoch VT_D Engine Coherency support Coherency Support Isoch Enable Disable Isoch VT_D Engine Coherency support Enable IOAT Control to enable disable IOAT devices No Snoop No Snoop Enable Disable for...

Страница 55: ...erprises Inc PH 978 688 2000 Email sales win ent com PCH Devices Enable Disable Intel R IO Controller Hub devices PCH SATA Configuration SATA devices and settings USB Configuration USB Configuration S...

Страница 56: ...SMBUS Device Enable Disable SMBUS Device PCH Server Error Reporting Mode SERM When enabled MCH is the final target of all errors otherwise SPCH is the final target to all errors PCH Display Enables Di...

Страница 57: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com PCH CRID Enable Disable PCH s CRID...

Страница 58: ...Hard Disk Drive Support Aggressive Link Power Management Enables Disables SALP SATA Port DevSlp Enable Disable SATA Port 2 DevSlp Board rework for LP needed before enable Spin Up Device If enabled fo...

Страница 59: ...e claimed by XHCI driver Port 60 64 Emulation Enables I O port 60h 64h emulation support This should be enabled for the complete USB keyboard legacy support for non USB aware OSes USB transfer time ou...

Страница 60: ...c PH 978 688 2000 Email sales win ent com 4 6 Server Management BMC Support Enable Disable interfaces to communicate with BMC Wait For BMC Wait For BMC response for specified time out In PILOTII BMC s...

Страница 61: ...enu Use the Security Setup option as follows 1 Choose Security from the main menu The following screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields...

Страница 62: ...have set a password this item shows Installed User Password Set User Password 4 8 Boot Menu Setup Prompt Timeout Use the and keys to adjust the number of seconds to wait for setup activation key Bootu...

Страница 63: ...screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields using the PgUP PgDN keys For information on the various options please press F1 key 3 Press the...

Страница 64: ...software 5 1 Operation System Supporting PL 10590 can support Windows and Linux operation system as follows Before installation please check your OS version If your OS is not in the following list ple...

Страница 65: ...on Appendix A DOS Linux Sample Code We offer some sample code for PL 10590 appliance for customer need that sample code is putted into the Driver CD for software development use Appendix B Cable Devel...

Страница 66: ...WIN Enterprises Inc PH 978 688 2000 Email sales win ent com CB EC5200 00 CB CO5202 4 00 CB RJDB91 00 CB DB9200 00 CB IVGA01 00 CB IPS200 00 CB IUSB01 00...