WilTec 51545 Скачать руководство пользователя страница 1

 

Operation Manual

 

 

Multistage Centrifugal Pump

 

51545

–51547

 

 
 
 

 

 
 
 
 
 

 

Illustration similar, may vary depending on model

 

 
 
 
 
 
 
 
 
 
 
 
Read and follow the operating instructions and safety information before using for the first time. 
 
 
Technical changes reserved! 
Due to further developments, illustrations, functioning steps and technical data can differ insignificantly. 
 
Updating the documentation 
If you have suggestions for improvement or have found any irregularities, please contact us. 

 

Содержание 51545

Страница 1: ...operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ...service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Esch...

Страница 3: ...ect the pump from being damaged and overloaded Not disobeying the instructions can lead to damages of the pump Assembly The pump must not be immersed in water Water is sucked in via a hose Install the pump slightly higher than the bottom to prevent dirt from blocking the suction end when the pump is used to pump very dirty water Never suspend the pump by its electric cables or lines Make sure that...

Страница 4: ...0 40 40 Checks before commissioning Make sure that the voltage and frequency correspond to the values stated on the nameplate of the motor Make sure that the condenser matched the requirements of the pump single phase Make sure that the suction via the hose is correct Check the direction of rotation Never let the pump run dry Never change the position of the floating switch as set up by the manufa...

Страница 5: ...WilTec de http www aoyue eu 10 2021 1 http www teichtip de Technical drawing and parts list Name Name Name 1 Impeller 5 Vent cover 9 Pump holder 2 Outlet 6 Holder 10 Mechanical seal 3 Clamping box 7 Rotor system 11 Intake housing 4 Vent 8 Wrapped stator 12 Pressure pin ...

Страница 6: ... by WilTec Wildanger Technik GmbH Item 51545 51547 Page 6 http www WilTec de http www aoyue eu 10 2021 1 http www teichtip de ...

Страница 7: ...wer failure b Check power supply c Low voltage during current peak c Install voltage stabiliser The pump irregularly discharges the water a Too small inlet pipe a Increase inlet pipe b Insufficient amount of water at the inlet b Improve the system try to increase the water flow c Too low liquid level c Try to increase liquid level d Too low intake pressure compared to water temperature pipe bend a...

Страница 8: ... and vibrations a Inlet pipe leak a Check inlet pipe b Inlet pipe too small or clogged by particles b Improve or repair inlet pipe c Air in the pump or inlet pipe c Re fill liquid remove air d Too low pump heads of device and pump d Improve system or choose a differ ent model e Friction of mechanical parts e Repair pump Only carry out e after consultation ...

Страница 9: ...er European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of ...

Отзывы: