9.4.2

Maintenance intervals for use in sewage lifting units

When the pump is used in sewage lifting units inside buildings or
on plots of land, carry out maintenance intervals and measures in
accordance with 

DIN EN 12056‑4

!

9.4.3

Maintenance intervals for harsh conditions

Under the following operating conditions, shorten the specified
maintenance intervals in consultation with the customer service:

Fluids with long-fibre components

Turbulent inlet (e.g. due to air entry, cavitation)

Highly corrosive or abrasive fluids

Strongly gassing fluids

Operation at an unfavourable duty point

Pressure surges

If there are harsh operating conditions, it is recommended to con-
clude a maintenance contract.

9.5

Maintenance measures

WARNING

Risk of injury from sharp edges on the cut-
ting device!

The macerator has extremely sharp edges. In addi-
tion, sharp edges can form on the suction port.
There is a danger of cuts!

• Wear protective gloves!
• Do not touch the macerator!

Before starting maintenance work, meet the following require-
ments:

Wear protective equipment! Observe the work regulations.

Safety shoes: Protection class S1 (uvex 1 sport S1)

Protective gloves: 4X42C (uvex C500 wet)

Safety goggles: uvex skyguard NT

For detailed marking of frame and disc, see the section on “Per-
sonal protective equipment [

}

 5]”.

The pump has been thoroughly cleaned and disinfected.

Motor must have cooled down to the ambient temperature.

Workplace:

Clean, good lighting and ventilation.

Firm and stable work surface.

Secured against falling over and slipping.

NOTICE! Only perform the maintenance work described in these
installation and operating instructions.

9.5.1

Recommended maintenance measures

Regular inspection of power consumption and the operating
voltage in all three phases is recommended for smooth operation.
In normal operation, these values remain constant. Slight fluctu-
ations depend on the characteristics of the fluid. Power consump-
tion can provide an early indication of damage or malfunctions in
the impeller, bearings or motor, which can be rectified. Larger
voltage fluctuations strain the motor winding and can cause the
pump to break down. Regular inspections can therefore largely
prevent major secondary damage and reduce the risk of total
breakdown. In this regard, it is recommended to use remote monit-
oring for regular inspections.

9.5.2

Visual inspection of the connection cable

Check connection cable for:

Bubbles

Cracks

Scratches

Abrasion

Pinch points

If the connection cable is damaged:

Decommission the pump immediately!

Have the connection cable replaced by the customer service!

CAUTION! Material damage! Damaged connection cables cause
water to enter the motor. Water in the motor leads to total
damage of the pump.

9.5.3

Visual inspection of accessories

Accessories must be checked for:

Correct fixation

Smooth function

Signs of wear, e.g. cracks caused by frequencies

Any defects detected must be repaired immediately or the ac-
cessories must be replaced.

9.5.4

Visual inspection of the coatings and housings

Coatings and housings must not show any damage. If there are de-
fects, observe the following:

Repair damaged coating. Order repair kits from the customer
service.

If housings are worn out, consult the customer service!

9.5.5

Function test of the monitoring device

To test resistances, the pump must be cooled down to the ambient
temperature!

9.5.5.1 Test the resistor of the temperature sensor

Ohmmeter available.

1.

Measure the resistance.

Measured value 

Bimetallic strip

: 0 ohms (passage).

Resistance checked. If the measured value deviates from
the specification, consult the customer service.

9.5.5.2 Testing the resistor of the external electrode for seal-

ing chamber control

Ohmmeter available.

1.

Measure the resistance.

Measured values “infinite (∞)”: Monitoring device OK.

Measured value ≤ 30 kOhm: Water in oil. Change oil.

Resistance checked. If the measured value still deviates
after the oil change, consult customer service.

Содержание Rexa FIT-S

Страница 1: ...Pioneering for You Wilo Rexa FIT S 6092602 Ed 01 2022 03 en Installation and operating instructions...

Страница 2: ...Rexa FIT S http qr wilo com 414 Rexa FIT https qr wilo com 771...

Страница 3: ...ials 9 5 3 Technical data 10 5 4 Type key 10 5 5 Scope of delivery 10 5 6 Accessories 10 6 Installation and electrical connection 10 6 1 Personnel qualifications 10 6 2 Installation types 10 6 3 Opera...

Страница 4: ...ent Non compliance with these instructions Improper use Incorrect storage or transport Incorrect installation or dismantling Insufficient maintenance Unauthorised repairs Inadequate construction site...

Страница 5: ...them during use of the product supervisor Persons with limited physical sensory or mental capacities Use of this product is pro hibited 2 3 Personal protective equipment The protective equipment spec...

Страница 6: ...quipment e g overvoltage undervoltage or phase failure relay etc Residual current device RCD Install a residual current device RCD in ac cordance with the regulations of the local en ergy supply compa...

Страница 7: ...et and pressure pipe Ensure minimum water submersion by using dry running protection Sound pressure level depends on several factors installation duty point etc Measure the current noise level under o...

Страница 8: ...ied to the transport company or the man ufacturer on the day of receipt of shipment Subsequently notified defects can no longer be asserted 3 2 Transport CAUTION Soaked packaging may tear The product...

Страница 9: ...contents e g sand gravel Intended use also includes compliance with this manual Any other use is regarded as non compliant with intended use 5 Product description 5 1 Description Fully submersible gri...

Страница 10: ...y for rated voltage P Additional electrical equipment O with bare cable end P with plug CEE 7 7 A with float switch and plug CEE 7 7 5 5 Scope of delivery Pump Installation and operating instructions...

Страница 11: ...le length are sufficient for the selected installation type Installation of switchgear Observe information in the manufac turer s instructions IP class overflow proof potentially explos ive atmosphere...

Страница 12: ...ace If the pump is used at the same location for a longer period of time bolt the pump support foot to the floor This reduces vi brations and enables quiet operation 1 6 5 3 4 2 OFF S1 S2 S3 Fig 5 Por...

Страница 13: ...l relay motor protection switch with temperature compensation differential triggering and anti reactivation device in accordance with the local regulations In case of sensitive mains make provision fo...

Страница 14: ...protection to the rated current according to the rating plate Partial load operation Set the motor protection to 5 above the current measured at the duty point 6 5 6 2 Soft starter Full load Set the m...

Страница 15: ...nding on the fill level ON OFF Switch the pump on and off in operating mode HAND Pump with attached plug Single phase AC version 1 motor Insert the plug into the socket the pump is ready for operation...

Страница 16: ...rotect the pump from frost and ice Minimum fluid temperature 3 C 37 F 1 Switch off the pump 2 Secure the operating point against being switched on again by unauthorised persons e g lock main switch Th...

Страница 17: ...equipment to the attachment point on the pump 3 Lift the pump approximately 30 cm 10 in above the ground 4 Spray the pump with clean water from top to bottom 5 Guide the water jet inwards through the...

Страница 18: ...remain constant Slight fluctu ations depend on the characteristics of the fluid Power consump tion can provide an early indication of damage or malfunctions in the impeller bearings or motor which can...

Страница 19: ...customer service 8 Pour in operating fluid Rotate the pump until the opening points upwards Pour the operating fluid into the opening Comply with the specifications for the operating fluid type and qu...

Страница 20: ...Wet fastening screw with thread locking fluid and screw it into cutting head Tighten the fastening screw hand tight 7 Secure the cutting head Insert wedge between cutting head and cutting plate CAUTIO...

Страница 21: ...r cushion in the pipe system Vent the pipe system If air cushions occur frequently Locate and prevent the air intake if required install ventilation systems at specified locations 6 Pump pumping again...

Страница 22: ...ent and putting your personal health at risk NOTICE Disposal in domestic waste is prohibited In the European Union this symbol may be included on the product the packaging or the accompanying document...

Страница 23: ......

Страница 24: ...Pioneering for You Local contact at www wilo com contact WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: