en
12
Installation and operating instructions • Drive for Wilo-Helix2.0-VE / Wilo-Medana CH3-LE • Ed.01/2022-06
Fig. 3: Rating plates
1
Pump rating plate
2
Drive type rating plate
Table 3: Rating plates
•
There is a serial number on the pump type rating plate. It must be specified e.g. for or-
dering spare parts.
•
The drive type plate is located on the side of the electronic module. The electrical con-
nection must be designed according to the specifications on the drive type rating plate.
5.2
Technical data
Property
Value
Note
Electrical connection
Voltage range
3~380 V ... 3~440 V (± 10 %),
50/60 Hz
Supported mains types:
TN, TT, IT
1)
performance range
3~ 0.55 kW ... 4.0 kW
depending on drive type
Speed range
1000 rpm... 3600 rpm
depending on drive type
Ambient conditions
2)
Protection class
IP55
EN 60529
Ambient temperature during opera-
tion min./max.
0 °C ... +50 °C
Lower or higher ambient temperatures on
request
Temperature during storage min./
max.
-30 °C ... +70 °C
> +60 °C limited to a duration of 8 weeks
Temperature during transport min./
max.
-30 °C ... +70 °C
> +60 °C limited to a duration of 8 weeks
relative humidity
< 95 %, non-condensing
Installation height max.
2000 m above sea level
Insulation class
F
Pollution degree
2
DIN EN 61800-5-1
Motor protection
Integrated
Surge protection
Integrated
Excess voltage category
OVC III + SPD/MOV
3)
Overvoltage Category III + Surge Protective
Device/ Metal Oxide Varistor
Protection function control termin-
als
SELV, galvanically isolated