13.3 Factory configuration
The normally used factory-saved values are presented in
the following table.
Electronics
Electromagnetic compatibility
EN 55022
Emitted interference
EN 61000-6-3
Interference resistance
EN 61000-6-2
Protection class
IP 20
Protection class
II
Materials
Housing
Lower part of housing: Plastic PC-ABS
Housing, upper part: Plastic PMMA/PC
1) In the range of +15 to +25°C
2) Device active, display lighting switched on
3) can be activated/deactivated via the termination switch (DIP switch) at the Central Control
13.2 Technical data
Temperature pre-settings
Comfort temperature
21°C
The default value of the Geniax System which
is suggested when creating a new time area
in the week profile.
Energy saving temperature
16°C
The default value of the Geniax System for
absence.
Minimum temperature
10°C
The lowest room temperature which can be
set for the building/rooms.
Maximum temperature
30°C
The highest room temperature which can be
set for the building/rooms.
Room frost protection tempera-
ture
8°C
The frost protection temperature set for all
rooms in the building by the Geniax System.
The value of the frost protection temperature
can be below the minimum temperature.
Temperature in the day period
21°C
The temperature set by the Geniax System
for presence.
End of the day period
22:00 hrs The end of the day period set by the Geniax
System.
Temperature in the night period
16°C
The temperature set by the Geniax System
for absence.
End of the night period
06:00 hrs The end of the night period set by the Geniax
System.