Chapter 6
Tools
Configuration
210
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
3
Although I have entered an IP address for the Willtek 4400 and a server
path, I do not see the mounted device in the list of directories (e.g. when
installing a new software version).
– Check if the IP address is valid and not already in use by another device
on the network. You can check this with any Windows PC, connected to
the same subnet/LAN: Open a command shell box (usually under Start-
Programs-Accessories) and enter the following command line:
ping
<address>
where <address> is the IP address of your Willtek 4400.
The ping should time out if the Willtek 4400 is switched off, but there
should be responses from your Willtek 4400 if it is up and running. If
there are pings while the Willtek 4400 is switched off, there is another
device (such as a PC or another test set) on the LAN using the same IP
address. In this case, modify the IP address of one of the devices.
If there is no ping even when the Willtek 4400 is switched on, the IP
address is not valid in this subnet or LAN, or the 4400 is not properly
connected to the network (check cabling).
– Check whether the remote PC runs an NFS server software. UNIX-like
operating systems typically include an NFS server; applications for
Windows are commercially available.
Parallel port settings
Printer —
This selection field is not accessible as the default setting
BMP File to Harddisk
cannot be altered.
The current screen of the Willtek 4400 will be saved as a bit-map file (*.BMP) on
the internal hard disk of the test set, in folder /io/screenshots. During this saving
process, a prompt will be displayed on-screen. The saving can be aborted by
pushing the
E
SC
function key or the corresponding key of the external keyboard
as long as the prompt is visible.
The bit-map file may then be copied or moved to a PC using the USB memory
stick (from the File menu within RAPID!) or the TCP/IP interface, and processed
using standard word processing or DTP software. The size of a single bit-map file
is approx. 901kB.
Ethernet display field
This display field is only available for serial numbers above and including
0911001. It shows the current status of the Ethernet interface and the related
network connections:
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...