background image

WBD-111

 

Hardware Manual 

Revision 1.0 

22 August 2008 

Copyright © 2008 WILIGEAR 

www.wiligear.com

 

 

4Gon   www.4Gon.co.uk   [email protected]   Tel: +44 (0)1245 808295   Fax: +44 (0)1245 808299 

Содержание WBD-111

Страница 1: ...WBD 111 Hardware Manual Revision 1 0 22 August 2008 Copyright 2008 WILIGEAR www wiligear com 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299...

Страница 2: ...information in this manual has been compiled with great care it may not be deemed an assurance of product characteristics WILIGEAR shall be liable only to the degree specified in the terms of sale an...

Страница 3: ...ODUCT DESCRIPTION 4 Features 4 WBD 111 DETAILS 5 CPU 5 RAM 6 Flash 6 Mini PCI 6 Ethernet 6 LEDs 6 Reset button 6 Jumpers 7 Power 8 SPECIFICATIONS 9 Electrical 9 Mechanical 9 Environmental 9 SOFTWARE 1...

Страница 4: ...M architecture processor with embedded MMU data instruction caches network and security acceleration engines 32 MB RAM and 8 MB Flash One Mini PCI slot accepts 802 11 and WiMAX high power radios One 1...

Страница 5: ...ssor Feature highlights 32 bit 400MIPS ARM9 RISC architecture processor 300MHz speed Embedded MMU and 8K 16K data instruction cache Supports 512MByte 16 bit 333MHz PC2700 of external DDR SDRAM Dual US...

Страница 6: ...tation electrostatic discarge ESD protection rated at 6 kV accepts power over Ethernet PoE functionality with 9 18V voltage power injectors LEDs Device has 2 green LEDs see picture above L1 power LED...

Страница 7: ...in 5 is wired differently and turned on by low signal External reset button should be connected to SOFT_RST and ground pins J3 Pin Connection J3 Pin Connection 1 3 3V 2 Ground 3 3 3V power LED 4 R LED...

Страница 8: ...h two onboard SMD fuses Power jack accepts DC 1 4 3 4 mm coaxial power connectors Conditions 9V 12V 18V Idle with no radio card and LAN disconnected 0 22A 2 0W 0 16A 1 9W 0 10A 1 8W Idle with no radio...

Страница 9: ...Mechanical Dimensions 90mm x 81mm x 18mm Weight 55g Environmental Operating parameters Temperature 25 C to 65 C Humidity 20 to 90 non condensing Storage parameters Temperature 40 C to 85 C Humidity 5...

Страница 10: ...low the steps 1 Setup TFTP server with an IP address 192 168 1 254 and put firmware file renamed to fwupdate bin to TFTP server s directory 2 Make sure that WBD 111 and TFTP server are on the same net...