background image

WIL-10330-E-04

 

WILDEN PUMP & ENGINEERING, LLC

The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show fl ow  pattern 
through the pump upon its initial stroke. It is assumed the pump has no fl uid in it prior to its initial stroke.

FIGURE 1

  The air valve directs pressurized 

air to the back side of diaphragm A. The 
compressed air is applied directly to the 
liquid column separated by elastomeric 
diaphragms. The diaphragm acts as 
a separation membrane between the 
compressed air and liquid, balancing the 
load and removing mechanical stress 
from the diaphragm. The compressed 
air moves the diaphragm away from 
the center of the pump. The opposite 
diaphragm is pulled in by the shaft 
connected to the pressurized diaphragm. 
Diaphragm B is on its suction stroke; air 
behind the diaphragm has been forced 
out to atmosphere through the exhaust 
port of the pump. The movement of 
diaphragm B toward the center of the 
pump creates a vacuum within chamber B. 
Atmospheric pressure forces fl uid  into 
the inlet manifold forcing the inlet valve 
ball off its seat. Liquid is free to move 
past the inlet valve ball and fi ll the liquid 
chamber (see shaded area).

FIGURE 2

 When the pressurized diaphragm, 

diaphragm A, reaches the limit of its discharge 
stroke, the air valve redirects pressurized 
air to the back side of diaphragm B. The 
pressurized air forces diaphragm B away 
from the center while pulling diaphragm A 
to the center. Diaphragm B is now on its 
discharge stroke. Diaphragm B forces the 
inlet valve ball onto its seat due to the 
hydraulic forces developed in the liquid 
chamber and manifold of the pump. These 
same hydraulic forces lift the discharge 
valve ball off its seat, while the opposite 
discharge valve ball is forced onto its seat, 
forcing fl uid to fl ow through the pump 
discharge. The movement of diaphragm A 
toward the center  of the pump creates a 
vacuum  within  liquid  chamber  A.  Atmos-
pheric pressure forces fl uid into the inlet 
manifold of the pump. The inlet valve ball 
is forced off its seat allowing the fl uid being 
pumped to fi ll the liquid chamber.

FIGURE 3

    At  completion  of  the  stroke, 

the air valve again redirects air to the 
back side of diaphragm A, which starts 
diaphragm B on its exhaust stroke. As 
the pump reaches its original starting 
point, each diaphragm has gone through 
one exhaust and one discharge stroke. 
This constitutes one complete pumping 
cycle. The pump may take several cycles 
to completely prime depending on the 
conditions of the application.

The Pro-Flo

®

 patented air distribution system incorporates two 

moving parts: the air valve spool and the pilot spool. The heart of 
the system is the air valve spool and air valve. This valve design 
incorporates an unbalanced spool. The smaller end of the spool 
is pressurized continuously, while the large end is alternately 
pressurized then exhausted to move the spool. The spool directs 
pressurized air to one air chamber while exhausting the other. 
The air causes the main shaft/diaphragm assembly to shift to 
one side — discharging liquid on that side and pulling liquid in 
on the other side. When the shaft reaches the end of its stroke, 
the inner piston actuates the pilot spool, which pressurizes and 
exhausts the large end of the air valve spool. The repositioning 
of the air valve spool routes the air to the other air chamber.

H O W   I T   W O R K S — A I R   D I S T R I B U T I O N   S Y S T E M 

S e c t i o n   3

H O W   I T   W O R K S — P U M P

Содержание Original PX15

Страница 1: ...Engine e ri n g Opera ti o n Maint e n a n ce Original Series METAL Pumps PX15 S i m p l i f y y o u r p r o c e s s WIL 10330 E 04 REPLACES WIL 10330 E 03...

Страница 2: ...ber Fitted 10 TPE Fitted 11 PTFE Fitted 12 Full Stroke PTFE Fitted 13 Ultra Flex Fitted 14 B Suction Lift Curves 15 SECTION 6 SUGGESTED INSTALLATION OPERATION TROUBLESHOOTING 16 SECTION 7 ASSEMBLY DIS...

Страница 3: ...wetted pump components Consult Chemical Resistance Guide E4 CAUTION Do not exceed 82 C 180 F air inlet temperature for Pro Flo X models CAUTION Pumps should be thoroughly flushed before installing int...

Страница 4: ...Hytrel Cream EP EPDM Blue Dot 2 NE NEOPRENE Green Dot PU POLYURETHANE Brown TF PTFE White 2 VT VITON Silver or White Dot WF WIL FLEX Santoprene Orange Dot VALVE SEAT A ALUMINUM BN BUNA N Red Dot EP E...

Страница 5: ...of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The...

Страница 6: ...L 427 16 8 M 599 23 6 N 363 14 3 P 307 12 1 R 257 10 1 S 282 11 1 T 18 0 7 U 71 2 8 V 69 2 7 W 307 12 1 X 84 3 3 Y 305 12 0 Z 478 18 8 AA 15 DIA 6 DIA DIMENSIONS ITEM METRIC mm STANDARD inch A 521 20...

Страница 7: ...PX15 M E T A L P X 1 5 P E R F O R M A N C E WIL 10330 T 02...

Страница 8: ...bility that exceeds previous industry standards Pro Flo XTM Operating Principal Turning the dial changes the relationship between air inlet and exhaust porting Each dial setting represents an entirely...

Страница 9: ...this case 9 8 scfm Step 2 Determining flow and air X Factors Locate your discharge pressure 40 psig on the verti cal axis of the EMS curve Figure 2 Follow along the 2 8 bar 40 psig horizontal line unt...

Страница 10: ...ig discharge pressure After locat ing this point on the flow curve draw a verti cal line downward until reaching the bottom scale on the chart and identify the flow rate In our example it is 38 6 lpm...

Страница 11: ...ifferent than the flow point plotted in example 2 1 After estimating or interpolating this point on the curve draw a vertical line downward until reaching the bottom scale on the chart and identify th...

Страница 12: ...setting For any EMS setting and discharge pressure the X factor is used as a multi plier with the original values from the setting 4 performance curve to calculate the actual fl ow and air consumptio...

Страница 13: ...as reduced by 46 thus providing increased effi ciency For a detailed example for how to set your EMS see beginning of performance curve section Caution Do not exceed 8 6 bar 125 psig air supply pressu...

Страница 14: ...etting For any EMS setting and discharge pressure the X factor is used as a multi plier with the original values from the setting 4 performance curve to calculate the actual fl ow and air consumption...

Страница 15: ...MS setting For any EMS setting and discharge pressure the X factor is used as a multi plier with the original values from the setting 4 performance curve to calculate the actual fl ow and air consumpt...

Страница 16: ...umption was reduced by 78 thus providing increased ef fi ciency For a detailed example for how to set your EMS see beginning of performance curve section Caution Do not exceed 8 6 bar 125 psig air sup...

Страница 17: ...many variables which can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumping fluid elevation atmospheric pressure and pipe friction loss all aff...

Страница 18: ...umping volume can be estimated by counting the number of strokes per minute and then multiplying the figure by the displacement per stroke MUFFLER Sound levels are reduced below OSHA specifications us...

Страница 19: ...UMPS To stop the pump from operating in an emergency situation simply close the shut off valve user supplied installed in the air supply line A properly functioning valve will stop the air supply to t...

Страница 20: ...le to identify pumps that are poorly suited to their applications T R O U B L E S H O O T I N G Pump will not run or runs slowly 1 Ensure that the air inlet pressure is at least 0 4 bar 5 psig above s...

Страница 21: ...of any hazardous effects of contact with your process fluid NOTE The model photographed for these instructions incorporates rubber diaphragms balls and seats Models with PTFE diaphragms balls and seat...

Страница 22: ...en the intake manifold to the liquid chambers Step 6 Lift intake manifold to expose intake valve balls and seats Inspect ball cage area of liquid chamber for excessive wear or damage Step 7 Remove one...

Страница 23: ...shaft for signs of wear or chemical attack Replace all worn parts with genuine Wilden parts for reliable performance Step 10 To remove diaphragm assembly from shaft secure shaft with soft jaws a vise...

Страница 24: ...contact with your process fluid The Wilden PX15 metal pump utilizes a revolutionary Pro Flo air distribution system Proprietary composite seals reduce the coefficient of friction and allow lube free o...

Страница 25: ...ring on both sides of center section with snap ring pliers Step 9 With o ring pick gently remove the o ring from the opposite side of the notched end of the spool Gently remove the pilot spool from sl...

Страница 26: ...7010 08 into the pilot spool bleed port located at the front of the center block Step 2 Next install an optional submersible air valve gasket 04 2621 52 The submersible air valve gasket can be purchas...

Страница 27: ...leaned to ensure no debris is left that may cause premature damage to the new seals INSTALLATION The following tools can be used to aid in the installation of the new seals Needle Nose Pliers Phillips...

Страница 28: ...4 PX15 METAL F u ll S t r o ke F i t t e d E X P L O D E D V I E W S e c t i o n 8 E X P L O D E D V I E W PA R T S L I S T I N G ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS see section 9...

Страница 29: ...asher Inner Piston Back up 2 15 6850 08 15 6850 08 15 6850 08 15 6850 08 15 6850 08 15 6850 08 22 Piston Inner 2 15 3700 01 15 3700 01 15 3700 01 15 3700 01 15 3700 03 15 3700 03 23 Outer Piston Bolt...

Страница 30: ...ERING LLC 28 WIL 10330 E 04 PX15 METAL R e d u c e d S t r o ke F i t t e d E X P L O D E D V I E W E X P L O D E D V I E W P A R T S L I S T I N G ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR...

Страница 31: ...sher Flat 406 x 812 x 065 8 15 6740 08 50 15 6740 08 50 15 6740 08 50 15 6740 08 50 15 6740 08 50 15 6740 08 50 20 Shaft 1 15 3805 09 15 3805 09 15 3805 09 15 3805 09 15 3805 09 15 3805 09 21 Piston I...

Страница 32: ...GINEERING LLC 30 WIL 10330 E 04 PX15 METAL F u ll S t r o ke F i t t e d Plastic Center Block Assm E X P L O D E D V I E W E X P L O D E D V I E W P A R T S L I S T I N G SCREEN BASE OPTION FULL STROK...

Страница 33: ...08 15 6130 08 15 6130 08 15 6130 08 19 Retaining Ring 2 04 3890 03 04 3890 03 04 3890 03 04 3890 03 04 3890 03 04 3890 03 20 Washer Flat 406 x 812 x 065 8 15 6740 08 50 15 6740 08 50 15 6740 08 50 15...

Страница 34: ...WILDEN PUMP ENGINEERING LLC 32 WIL 10330 E 04 PX15 METAL R e d u c e d S t r o ke F i t t e d Plastic Center Block Assm E X P L O D E D V I E W E X P L O D E D V I E W P A R T S L I S T I N G...

Страница 35: ...15 6130 08 19 Retaining Ring 2 04 3890 03 04 3890 03 04 3890 03 04 3890 03 04 3890 03 04 3890 03 20 Washer Flat 406 x 812 x 065 8 15 6740 08 50 15 6740 08 50 15 6740 08 50 15 6740 08 50 15 6740 08 50...

Страница 36: ...80 58 15 1120 58 N A Aluminum N A N A N A N A 15 1121 01 N A Stainless Steel N A N A N A N A 15 1121 03 N A Mild Steel N A N A N A N A 15 1121 08 N A Consult P S UF for Ultra Flex information 1 Used o...

Страница 37: ...N O T E S...

Страница 38: ...N O T E S...

Страница 39: ...comes rst Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability...