Differential pressure gauge models 712.15.160, 732.15.160, optional for hazardous areas
11265191.10 08/2019 EN/DE
13
EN
Panel mounting (option)
Measuring cell Adjustable scale ranges
from
to
140 mbar
0 ... 40 mbar
0 ... 140 mbar
280 mbar
0 ... 80 mbar
0 ... 280 mbar
560 mbar
0 ... 160 mbar
0 ... 560 mbar
1,130 mbar
0 ... 320 mbar
0 ... 1,130 mbar
2,300 mbar
0 ... 650 mbar
0 ... 2,300 mbar
4,000 mbar
0 ... 1,150 mbar
0 ... 4,000 mbar
4.2 Differential pressure display
The measuring span of the differential pressure gauge can, depending on the measuring
cell, be adjusted within the measuring range limits given in the table. Ideally, this adjustment
should be made on a test bench, though it can also be carried out at the measuring point
using a hand test pump.
Measuring range limits
4. Commissioning, operation
11248832.02
Panel cutout
Panel