EN
19
Operation elements and connections
LC-display
Measurement function selection
switch
Input sockets for measurement
ranges
Ground connection for all measure-
ment ranges
Input socket for current measure-
ment range 10 A
SELECT
RELATIVE
HOLD
1
3
2
5
4
Digital multimeter
up to 600 V AC, CAT IV
Buttons
Activate short-press function (SELECT, RELATIVE or HOLD) by pressing the appropri-
ate button and then releasing it after single-beep sound (it will take less than 1 s).
Select
Use SELECT button to cycle through different measurement modes that share the
same position on the dial:
• Resistance, continuity, diode, capacitance
• Frequency, duty cycle
• Temperature scales: °C or °F
• AC/DC current measurement (in 10 A and in mA range)
To select desired measurement mode
Apply short press (less than 1 s) on the
SELECT button. After one beep sound
release the button.
SELECT
RELATIVE
HOLD
1
2
3
4
5