Configuration of gateways with samosPLAN
6
Wieland Electric GmbH | BA000970 | 07/2019 [9855]
44
Illustration 5: "Gateway configuration" tab for SP-EN-MOD
NOTICE
Allocation of input and output data
The output and input data listed here refer directly to the data blocks in tab 1 and tab 2.
•
Output data
group
(to the PLC)
:
Only
data set 1
can be configured. This refers directly to
Output data block 1
in tab 1.
•
Input data (from PLC)
group:
Data set 1
to
data set 5
refer directly to
input data block 1
to
input data block 5
in tab 2.
"Gateway” and “Properties” docking windows
81088011
In addition to the
Gateway
view, in the gateway configuration in samosPLAN
6 you work with the
following windows:
"Gateway” docking window
From the
Gateway
docking window you can drag hardware data bytes into empty cells in the rou-
ting table (
Gateway
view).
Illustration 6: Drag data bytes into the routing table using drag & drop
NOTICE
You can make use of the same data byte several times in the routing table.
"Properties” docking window
In the
Properties
docking window, the configuration dialog appears for the data byte which you ha-
ve selected in the
Gateway
view.
Depending on the data byte, you can configure individual parameters. You can also allocate tag na-
mes here.
5.1.4