Weldmatic 350 & 500 | Operator Manual | Model No CP144-2/CP145-2
11
10
Fig 1 Weldmatic 350 + 500 Controls
1 Control Panel
2 Remote Connector
Connect the wire feeder control cable to
this connection.
3 Positive Welding Output Terminal
4 Negative Welding Output Terminal
5 Power On Indicator
6 VRD Safe Light
VRD safe light is on when the open circuit
output voltage is reduced to a safe level.
7 Over Temperature Warning
If an over temperature condition is reached
the machine will prevent weld output and
wait until machine has cooled down, before
welding output can commence.
8 Digital Display Amps
If Weld Mode is stick MMA Mode or TIG
mode the display will indicate the selected
welding Amps when adjusted with knob,
item (9).
During welding in any mode, the display will
show actual welding Amps. At the end of
welding, the display will hold the actual weld
amps for 10 seconds.
4 CONTROLS
PANTONE 432 C
WHITE
PANTONE 426 C
PANTONE 116 C
WIRE
0.9
1.2
1.6
CORED WIRE
- Self/Gas Shielded
- All Sizes
MIG
STICK
TIG
MIG VS
(Hold 3 Sec.)
PROCESS
WIN649A
Design WIN649A
ON VRD
MIG ARC CONTROL
STICK ARC FORCE
AMPS
VOLTS
Proof with knob and push button design in place
11
8
5
6
7
9
10
12
13
1
2
4
3
Содержание CP144-1