background image

II. INTRODUCTION 

How it Works 

When the dehumidifier is started, the fan begins to pull moisture-laden air across the dehumidifying 
coils. The coils condense or draw moisture from the air, and air flows through the top louver into the 
room as dry, warm air. Moisture removed from air is collected in a water bucket on the front of the 
dehumidifier. 
 
The appliance is designed to operate between 41°F (5°C), and 96°F (35°C). The "Compressor" cir-
cuit has an automatic 3 minute time delayed start if the appliance is turned off and on quickly. This 
prevents overheating of the compressor and possible circuit breaker tripping. Make sure the water 
bucket is fitted correctly otherwise appliance will not turn on. 
 
 

Energy Saving Guide 

This Whynter dehumidifier is an Energy Star rated appliance. Follow the guide below can help to get 
the best performance and efficiency from your dehumidifier. 

 

Do not cover the air intake and outlet. 

 

Do not place the appliance in front of curtains or drapes- to ensure they do not obstruct the air 

intake. 

 

Keep curtains, blinds or drapes closed during the sunniest part of the day. 

 

Close all windows and doors. 

 

Indoor relative humidity should ideally be kept between 35%RH and 60%RH depending on the 

ambient temperature. 

 

Make sure the appliance is on a hard and level surface. 

 

To prolong the compressor's life, please wait at least 3 minutes before turning the appliance back 
on after shutting it off. 

 

Inspect and keep the air filter clean by cleaning regularly. 

 

Perform routine maintenance. 

MODEL : 

 

RPD-302W

 

Dehumidifying capacity 

30 pints/ day 

EEV (Liters per kW-Hour) 

CAN/CSA-C749-07 

Power supply 

115v/ 60Hz 

Maximum power input 

400W 

Current Consumption 

3.3 Amps 

Refrigerant 

R-134A / 7.8 Oz 

Air flow M3/H / CFM 

130 M3/H  /  110 CFM 

Fan speeds 

2 (H & L) 

Unit Dimensions 

21” H  x  13.25” W  x  9.75”  D  

(19.5” in H when casters are not installed) 

Unit Net Weight 

29.5 lbs 

Unit Gross Weight 

32 lbs 

Noise Level (dBA) 

48.4 

TECHNICAL DATA 

Содержание RPD-302W

Страница 1: ...UMIDIFIER Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future ref...

Страница 2: ...btained from your local municipal authority Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance from...

Страница 3: ...2 I SAFETY PRECAUTIONS 4 II INTRODUCTION 5 III PARTS AND CONTROLS 6 IV OPERATION INSTRUCTIONS 7 8 V CONTINUOUS DRAINAGE 9 VI MAINTENANCE 10 VII TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 11 VIII...

Страница 4: ...uately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multiple s...

Страница 5: ...your dehumidifier Do not cover the air intake and outlet Do not place the appliance in front of curtains or drapes to ensure they do not obstruct the air intake Keep curtains blinds or drapes closed...

Страница 6: ...ctivate Auto stop function and the Timer light will come on Set the desired time delay OFF hours by pressing the UP and DOWN and buttons The time increments are 1 hour up to 24 hours When the delay ti...

Страница 7: ...s happens the defrost lamp will turn on and the machine will go into periodic defrost mode automati cally Defrost time may vary If the dehumidifier freezes up turn the appliance off for few hours and...

Страница 8: ...of the dehumidifi er 2 Position the dehumidifier on its side 3 Locate the arrow on the bottom of the dehumidifier and insert the caster according to the arrow direction 4 Slide the caster in as far as...

Страница 9: ...appliance 7 Place the bucket on its original location INSTALLING DRAINAGE HOSE When using the function of continuous drainage the hose must be placed horizontally below the drainage hole Avoid uneven...

Страница 10: ...Do not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifier runs efficiently it is recommended to clean the air...

Страница 11: ...dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity inside your home and a good idea in general if your h...

Страница 12: ...d an additional dehumidifier for area Clean the air filter The appliance must be placed in a space that does not restrict air flowing into the rear coil or out of the front grill Set the RH level and...

Страница 13: ...r has an open circuit or humidity is less than 30 90 RH Humidity Sensor has short circuit or humidity is higher than 90 Lo Temperature is lower than 32 F or temperature sensor has an open circuit Hi T...

Страница 14: ...used by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage cau...

Отзывы: