Страница 1: ...UMIDIFIER Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference Model RPD 411WG INSTRUCTION MANUAL ...

Страница 2: ... be obtained from your local municipal authority Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance from your dehumidifier We trust that your Whynter dehumidifier will provide the performance and reliability that we stand for Your Whynter dehumidifier is designed to remove moisture in the air by co...

Страница 3: ... 2 SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 WATER DRAINAGE INSTRUCTIONS 11 12 MAINTENANCE 13 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 14 TROUBLESHOOTING 15 16 WARRANTY INFORMATION 17 ...

Страница 4: ... adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multiple socket or of an extension cord as it may overheat and become a risk of fire Make sure the power plug is clean before usage Do not turn this appliance on and off by plugging and unplugging Always u...

Страница 5: ...om your dehumidifier Do not cover the air intake and outlet Do not place the appliance in front of curtains or drapes to ensure they do not obstruct the air intake Keep curtains blinds or drapes closed during the sunniest part of the day Close all windows and doors Indoor relative humidity should ideally be kept between 35 RH and 60 RH depending on the ambient temperature Make sure the appliance i...

Страница 6: ...6 PARTS AND CONTROLS OTHER ACCESSORIES 1 20 Continuous Gravity Drain hose ...

Страница 7: ...ntil the water bucket is full The humidity level cannot be set The Cont indicator light will come on when this mode is selected 3 4 Buttons Humidity Set Control Buttons The humidity level can be set within a range of 35 RH Relative Humidity to 85 RH in 5 increments For low er humidity level press the button and set to a lower RH percentage value For higher humidity level press the button and set t...

Страница 8: ...the delay time set has elapsed the appliance turns on To cancel the delayed switch on function set the time to 00 or turn off the appliance Timer Delay Switch On and Off Sequence When the appliance is OFF press the Timer button to activate Auto start function and Timer light ON will come on Set the desired time delay ON hours by pressing the and buttons Once Timer Delay Switch On is placed press t...

Страница 9: ...nce will not operate satisfactorily if the room temperature is below 41 F 8 Display The display screen shows a number of different indications depending on the selection function Shows the set relative humidity level from 35 RH to 85 RH Shows Auto Start and Auto Stop time from 0 0 hour to 24 hours After the option settings are completed the display shows the approximate room humidity level in a ra...

Страница 10: ...h hard and level floor strong enough to support the appliance with a full bucket of water Do not attempt to roll the appliance over objects Avoid placing the appliance in an area where the tempera ture will fall below 53 F The coils may become covered with frost and may reduce performance Do not place the appliance near clothes dryer heater or radiator Shut all doors windows and openings to your t...

Страница 11: ...d or not positioned correctly Make sure that the drain bucket is properly installed and the in right position 1 The drain bucket can hold up to 10 pints of water When the bucket is full the compressor and fan will turn off the Water Full indicator will illuminate and a P2 code will be displayed 2 It is recommended to turn the unit off before removing the drain bucket 3 Grip the left and right hand...

Страница 12: ...the drainage hole Avoid uneven ground and folding the hose NOTE When using continuous gravity drainage setup there may be some water collected in the water in the drain bucket 1 Remove the rubber drain cover from the con tinuous gravity drain outlet at the back of the unit 2 Insert the continuous gravity drain hose through the continuous gravity drain outlet Make sure the hose is securely fastened...

Страница 13: ... the main unit NOTE Do not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifier runs efficiently it is rec ommended to clean the air filter at least once every two weeks Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt Rinse the air filter under warm or cold running water no hotter ...

Страница 14: ...oom If your home is musty you will want to use your portable dehu midifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by control ling the relative humidity inside your home and a good idea in general if your home has such underlying problems as a leaky foundation walls or inadequate ventilation or if you live in a humid area By keeping the rela...

Страница 15: ...laced in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but the room is not dry enough Humidity setting RH is too high The dehumidifier does not have sufficient clearance to operate Room temperature is too low Windows or doors are opened Set the humidity level to ...

Страница 16: ...ve the other appliances to another circuit Move the appliance onto another circuit with the correct voltage Call for service Only authorized person nel should replace damaged power cord or power plug If you want to remove more moisture set the unit on Continuous operation Empty drain bucket and insert the bucket to the appliance properly Water on floor Drain bucket is not installed properly Drain ...

Страница 17: ...aused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer Freight and Insurance cost for the warranty service DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REM...