background image

Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before 

using this product. Keep this manual in a safe place for future reference. 

Model # :

 

ARC-147WF 

Whynter Portable Air Conditioner with Dual Hose, Dehumidifier, Fan, 

up to 500 sq ft 14000 BTU (10000 BTU SACC), Remote Control, 

HEPA and Carbon Filter - White

INSTRUCTION MANUAL

Содержание ARC-147WF

Страница 1: ...struction Manual carefully before using this product Keep this manual in a safe place for future reference Model ARC 147WF Whynter Portable Air Conditioner with Dual Hose Dehumidifier Fan up to 500 sq ft 14000 BTU 10000 BTU SACC Remote Control HEPA and Carbon Filter White INSTRUCTION MANUAL ...

Страница 2: ...Exhaust Hose Installation 7 Choosing The Right Location Ambient Temperature Range For Unit Operation 7 Technical Data 8 Accessories 9 Control Panel 10 11 Remote Control 12 Installation 13 Maintenance 14 15 Troubleshooting 16 17 Table of Contents 7 Warranty 18 ...

Страница 3: ...acle Install the unit on a flat sturdy surface Failure to do so could result in damage or excessive noise and vibration The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards Do not modify the length of the power cord or use an extension cord to power the unit Do Do not share a single outlet with other electrical appliances Improper power supply can cau...

Страница 4: ...liance must be disconnected from the supply mains Do not remove any fixed covers Never use this appliance if it is not working properly or if it has been dropped or damaged Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not ope...

Страница 5: ...lated area where the room size corresponds to the room area as specified for operation Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing s...

Страница 6: ...nation of symbols displayed on the unit WARNING CAUTION CAUTION CAUTION This symbol shows that this appliance used a flammable refrigerant If the refrigerant is leaked and exposed to an external ignition source there is a risk of fire This symbol shows that the operation manual should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to t...

Страница 7: ...usage mode For COOL mode the exhaust hose must be installed For FAN or DRY mode the exhaust hose can optionally be removed Choosing The Right Location Your installation location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded plug and the Lower Drain Port found on the back of t...

Страница 8: ...its Federal regulations require manufacturers to calculate cooling capacity based on a specific test procedure which was changed just this year Models manufactured before 2017 were tested under a different procedure and cooling capacity is measured differently than in prior years models So while the BTUs may be lower the actual cooling capacity of the air conditioners has not changed What is SACC ...

Страница 9: ...s Note Remove and discard Accessories ACCESSORY IMAGE ACCESSORY DESCRIPTION QUANTITY 1 Exhaust Intake Hose 2 pieces 2 Hose Connector to Unit 2 pieces 3 Hose Connector to Window Kit 2 pieces 6 pieces Covers 2 pieces Window slider kit 1 set Remote control 1 piece 1 3 2 A B C ...

Страница 10: ...depending on which auto function is chose To cancel the delayed switch off function turn off the air conditioner or adjust the time setting to 0 0 5FNQFSBUVSF POUSPMT Press to adjust the temperature setting The default display is room temperature In cooling mode when or button is pressed the set temperature is displayed and may be adjusted After a few seconds the display will revert back to room t...

Страница 11: ...P UIF PVUTJEF BOE DPPMJOH XJUIJO UIF SPPN NBZ PDDVS G UIF FYIBVTU IPTF JT OPU WFOUFE UIF VOJU NBZ SFRVJSF NPSF GSFRVFOU ESBJOJOH EEJUJPOBMMZ UIF BJS DPOEJUJPOFS EPFT OPU IBWF B IVNJEJTUBU JO XIJDI B TQFDJGJD IVNJEJUZ MFWFM DBO CF TFU BO PEF In this mode only the fan of the air conditioner runs and circulates the air in the room To activate this function mode press the MODE button until the FAN ind...

Страница 12: ...ssing the key or LCD Display Fahrenheit Celsius Battery Placement Remove the cover on the back of the remote control and insert the batteries with the and poles pointing in the proper direction CAUTION Use only AAA batteries Remove the batteries if the remote control is not used for a month or longer Do not attempt to recharge the supplied batteries All batteries should be replaced at the same tim...

Страница 13: ...and nuts mounted on the two ends of the main panel A 1 Slide each hose assembly with the hose connector to unit into the exhaust and intake ports of the rear panel firmly in place 3 Open the window and place the window panel kit into the window Adjust the extension panels B and C to fit width or height of window using the screw and nut sets mounted on the main panel A Installation ...

Страница 14: ...g on use 1 Switch off the air conditioner 2 Pull the pre filter frame from the unit 3 Remove the activated carbon filter from the pre filter 4 Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the pre filter 5 Rinse the pre filter thoroughly under warm running water no hotter than 100 F 6 Dry thoroughly before re inserting the filters NOTE The activated carbon filter and HEPA ...

Страница 15: ...Gather the power cord and bundle it Remove the batteries from the remote If leaving the window kit in place disconnect the exhaust and intake hose from the window slider kit and place the included covers on the kit Otherwise remove the window kit from the window opening Note Depending on use it is recommended that the air conditioner be cleaned internally annually Please contact Whynter at support...

Страница 16: ...rn on the fan runs but the unit is not cooling The room temperature is outside of the operational tolerances of the unit The Cooling mode is not on The compressor has not turned on yet because of its time delay The set temperature is too high The internal water reservoir is full and the TANK FULL indicator appears on the display This unit is designed to work in ambient temperatures of 63 F to 90 F...

Страница 17: ... You may need additional cooling or another air conditioner Close curtains or blinds and try to minimize the amount of direct sunlight into the room You may need additional cooling or another air conditioner The unit is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with...

Страница 18: ...s Use in commercial or industrial applications Damage accidental or otherwise to the product while in the possession of a consumernot caused by a defect in material or workmanship Damage caused by consumer misuse tampering lack of maintenance or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear D...

Отзывы: