GENERAL INFORMATION

1) A qualified electrician, in accordance with IEE wiring regulations should carry out connection to
mains wiring.

2) This unit must be EARTHED.

3) Ensure that the rated voltage and frequency requirements are compatible with the available mains
supply.

4) Cleaning of reflectors and lenses should be carried out using clean, soft and lint free cloths and
anti-static cleaning fluid

5) Do not carry out high voltage insulation test, i.e. 500/1000v this may damage internal components.

SPECIFICATION

Lumen Outputs and wattages

470Lumen 7.2W

Finish

960Lumen 14.4W

Materials                                                                  Reinforced mild steel or 316 Marine Grade
                                                                                Steel Body (see options on website),
                                                                                Polycarbonate cover
Weight

9Kg; add 7Kg for root option & 3.5Kg
for flange option

Supply

230/240v AC 50-60Hz

Connection

2.5mm

2

 input terminal block

Ingress Protection

IP65

For maximum number of fitting on a MCB Type please contact Technical Support