Model # UP310
Made in China
Universal Thermostat
with
scheduling
37-7577A
Install Guide
Want to install the easy way?
Страница 1: ...Model UP310 Made in China Universal Thermostat with scheduling 37 7577A Install Guide Want to install the easy way...
Страница 2: ...iring and configuring your new thermostat 15 Checking thermostat operation 22 Using your thermostat 24 Speci cations 30 Troubleshooting 31 Failure to follow and read all instructions carefully before...
Страница 3: ...age contents This package should contain the following items 1 2 Gather tools Thermostat Mounting screws and wall anchors x2 2 AA batteries Terminal wire label stickers Installation instructions Requi...
Страница 4: ...tem button Backlight button Raises temperature setting Access menu options Lowers temperature setting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10...
Страница 5: ...9 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Menu F...
Страница 6: ...y of the week used when programming a schedule Permanent hold bypassing the schedule Temperature setpoint Appears when the keypad is locked to prevent unwanted changes 1 2 3 4 5 6 7 8 9 10 11 12 13 14...
Страница 7: ...1 12 13 14 15 16 17 18 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 2 3 4 5 6 7 8 9 10 11...
Страница 8: ...ower to the system at the main fuse or circuit breaker box or by ipping a switch at the air handler Do not restore power until installation is complete WARNING To ensure the power to your heating and...
Страница 9: ...Tip Taking a picture with a camera or smartphone can help you not only remember how wires are connected to the terminals but can also ensure that you label your wires correctly Mislabeling the wires...
Страница 10: ...ference we ve included a terminal label reference chart below to help you connect the wires from your old thermostat to your new thermostat in case you get stuck Terminal labeling reference chart If y...
Страница 11: ...ith the following letters Terminal function W2 W2 2nd Stage Heat Conventional 2nd Stage Auxiliary Heat Heat Pump Y Y1 Y 1st Stage Compressor Y2 Y2 2nd Stage compressor G G Fan Relay O B O B O B Revers...
Страница 12: ...the wire as O B On heat pump systems with separate W2 and E wires label both wires W E 2 wires on one terminal 3 4 Identify jumper wire For terminal RC and RH On your old thermostat if Then on your n...
Страница 13: ...13 50 60HZ OR DC 0 05 TO 1 5 AMP PER TERMINAL 2 5 AMPS MAX COMBINED LOAD CLASS 2 0150 XXXXXX E1 XXXX 5001 8186 REV X UP MADE IN CHINA EMERSON RC RH Jumper Wire...
Страница 14: ...ith all of your wires disconnected and properly labeled you may now safely remove the thermostat base from your wall Tip Worried about having your wires falling into your wall Keep the wires secure by...
Страница 15: ...w thermostat base Mount your new thermostat base using the supplied screws Drill holes and insert wall anchors to secure the thermostat base to the wall if necessary Leveling Thermostat Leveling is fo...
Страница 16: ...thermostat base Insert each labeled wire into the hole of it s matching terminal and using the screwdriver tighten the screw on the terminal block securely RC RH O B RH Take care when securing and rou...
Страница 17: ...he settings that match your new thermostat s wiring This information will be used in Step 4 5 to configure your thermostat Thermostat Terminals with attached wires Outdoor Equipment Setting Used in 4...
Страница 18: ...on thermostat terminal W E Blower only no indoor heating equipment FAN W E Gas or Oil heat Single stage gas or oil furnace GA1 W E W2 Gas or Oil heat Two stage gas or oil furnace GA2 W E Electric hea...
Страница 19: ...nds to launch the installer menu Your screen will change to the configuration menu Set the first 3 items 05 10 15 to match your equipment Please refer to the table in Section 4 3 and Section 3 3 to fi...
Страница 20: ...0 AC1 AC2 HP1 HP2 Refer to Section 4 3 10 Indoor Equipment selects whether the equipment is a gas furnace electric furnace or fan only EL2 FAN GA1 GA2 EL1 EL2 Refer to Section 4 3 20 Reversing valve s...
Страница 21: ...mum set point for heat mode 99 47 to 99 66 Minimum Cool Limit minimum set point for cool mode 45 45 to 97 Setting the reversing valve to O or B is necessary for heat pump systems only Please refer to...
Страница 22: ...ress the fan button to select the AUTO position The blower should stop immediately Tip If at any time during testing your system does not operate properly please contact Customer Support at 877 654 93...
Страница 23: ...liary 4 Press to adjust thermostat setting below room temperature The heating system should stop operating and the Heat On icon will disappear 5 3 Auxiliary only mode heat pump systems 1 Press the sys...
Страница 24: ...On There can be up to a 5 minute delay see INSTALLER MENU item 50 3 Press to adjust thermostat setting to 1 above room temperature The cooling system should stop operating and the Cool On icon will di...
Страница 25: ...y or Non Programmable 5 7 7 Day 5 5 1 1 Day 0 Non Programmable 02 Early Start starts heating or cooling early so your programmed tempera ture is reached by the programmed time OFF On start early OFF s...
Страница 26: ...e required OFF On always on OFF momentarily 06 Change Air Filter set up a monthly reminder OFF 1 to 12 reminder time months OFF no filter reminder 07 Auto Changeover thermostat automatically switches...
Страница 27: ...y 5 Press Exit when finished The default program is 5 1 1 Day but can be setup as a 7 Day or Non Programmable thermostat refer to the User Menu on pages 25 26 Hold Temperature bypassing the schedule W...
Страница 28: ...ure On press and hold and the Menu button until the icon appears this can also be turned on in the menu To turn Off press and hold and the Menu button for 3 seconds 6 3 Thermostat schedule Energy Savi...
Страница 29: ...flash use or to set the temperature for the current period 6 Continue to press Next to advance through all periods Wake Leave Return Sleep for all days of the week Note Press Back to return to the pr...
Страница 30: ...37 C Rated Differentials 6 F Hr Fast Med Slow Heat Conventional Gas Oil Elect 0 5 F 0 75 F 1 9 F Cool Central Air 0 9 F 1 2 F 1 7 F Heat Pump Heat and Cool 0 9 F 1 2 F 1 7 F Heat Pump Aux 0 5 F 0 75...
Страница 31: ...switch to ON 3 Replace door panel in proper position to engage safety interlock or door switch 4 Tighten connections No Heat 1 System not set to Heat 2 Loose connection to thermostat or system 3 Heati...
Страница 32: ...m is operating correctly No Cool 1 System not set to Cool 2 Loose connection to thermostat or system 3 Cooling System requires service or thermostat requires replacement 1 Set thermostat to Cool 2 Ver...
Страница 33: ...e influencing the cycle rate Display can be adjusted 5 See User Menu item 05 Furnace Air Conditioner Cycles Too Fast or Slow narrow or wide temperature swing The location of the thermostat and or the...
Страница 34: ...t is needed 4 None of the buttons operate on the thermostat 5 If Call for Service is flashing com pressor self diagnostic is detecting an issue with the outdoor unit 1 See corrective action for No Hea...
Страница 35: ...be reset by removing the batteries for 2 minutes This reset will not change the menu settings or program If the condition persists after reinstalling the batteries replace the thermostat To convenient...
Страница 36: ...ury must not be discarded in household trash Refer to thermostat recycle org for location to send product containing mercury FOR CALIFORNIA RESIDENTS Warning This product contains a chemical known to...