White Rodgers IF72 Скачать руководство пользователя страница 1

Installation Instructions for

Heating & Air Conditioning

IF72

5/2 Day Programmable

Heat Pump Thermostat

CONTENTS

Preparations .................................................. 1

Thermostat Details ........................................ 1

Removing Old Thermostat ......................... 1-2

Mounting and Wiring .................................. 2-3

Check Thermostat Operation ..................... 4-5

Programming your Thermostat .................. 6-7

Specifications ................................................ 7

Troubleshooting ......................................... 7-8

PREPARATIONS

THERMOSTAT DETAILS

REMOVING OLD THERMOSTAT

Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.

1. Remove Old Thermostat:  A standard heat/cool thermostat

consists of three basic parts:

a. The cover, which may be either a snap-on or hinge type.

b. The base, which is removed by loosening all captive screws.

c. The switching subbase, which is removed by unscrewing

the mounting screws that hold it on the wall or adaptor plate.

2. Shut off electricity at the main fuse box until installation is

complete. Ensure that electrical power is disconnected.

3. Remove the front cover of the old thermostat. With wires still

attached, remove wall plate from the wall. If the old thermostat
has a wall mounting plate, remove the thermostat and the wall
mounting plate as an assembly.

4. Identify each wire attached to the old thermostat using the

labels enclosed with the new thermostat.

5. Disconnect the wires from the old thermostat one at a time. DO

NOT LET WIRES FALL BACK INTO THE WALL.

6. Install new thermostat using the following procedures.

To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.

CAUTION

!

Printed in U.S.A.

PART NO. 37-6367D

Replaces 37-6367C

0224

WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com

Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage.

Assemble tools required as shown below.

YOUR THERMOSTAT  REPLACES

1

2

3

WIRE CUTTER/STRIPPER

Description

Heat Pump (No Aux or Emergency Heat)

Yes

Heat Pump (with Aux or Emergency Heat)

Yes

Standard Heat & Cooling Systems

No

Standard Heat Only Systems

No

Millivolt Heat Only Systems – Floor or Wall Furnaces

No

Standard Central Air Conditioning

No

Gas or Oil Heat

No

Electric Furnace

No

Hydronic (Hot Water) Zone Heat – 2 Wires

No

Hydronic (Hot Water) Zone Heat – 3 Wires

No

HAND OR POWER 
DRILL WITH 3/16 INCH 
DRILL BIT, IF NEEDED

FLAT BLADE SCREWDRIVER

SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL— 

THERMOSTAT DOES NOT NEED TO BE LEVEL TO WORK PROPERLY

Figure 1. Thermostat base

W905

Clip for

Slow Cycle

W904

Clip for

Celsius

Mounting

hole

W906 for Emergency

Heat Second Stage

Fan Control

O/B 

Terminal

Switches 

Selection

Mounting

hole

IF72

Содержание IF72

Страница 1: ...res from the old thermostat one at a time DO NOT LET WIRES FALL BACK INTO THE WALL 6 Install new thermostat using the following procedures To prevent electrical shock and or equipment damage disconnec...

Страница 2: ...1st stage at approximately 1 2 F and 2nd stage 0 75 F If you prefer slow cycle clip jump W905 The 1st stage and 2nd stage would be 1 5 F and 1 2 F respectively O B Terminal Switch Selection The O B s...

Страница 3: ...FF If safety circuits are in only one of the systems remove the transformer of the system with NO safety circuits NOTE Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency...

Страница 4: ...is typically used when compressor operation is not desired or you prefer back up heat only 1 Move SYSTEM switch to EMER position EMER will flash on the display 2 Press to adjust thermostat setting ab...

Страница 5: ...A on OFF HOLD HOLD RUN CL OFF Press HOLD to advance to next item or TIME to move backwards to previous item CHECK THERMOSTAT OPERATION CONTINUED FROM FOURTH PAGE 5 2 Select Compressor Lockout CL OFF o...

Страница 6: ...during each period You may also want to look at the sample program table to get an idea of how the thermostat can be programmed Entering Your Program Follow these steps to enter the heating and coolin...

Страница 7: ...ress RUN 4 Move SYSTEM switch to COOL position 5 Repeat step 2 to check cooling temperatures 6 Press RUN to begin program operation YOURTHERMOSTATISNOWCOMPLETELYPROGRAMMED AND READY TO AUTOMATICALLY P...

Страница 8: ...at Cool system for correct operation If the system operates correctly replace the thermostat Furnace Cycles Too Fast or Too Slow 1 The location of the thermostat and or the Digital thermostats normall...