COMFORTPRO

AIR CLEANERS

AIR CLEANER

PROGRAMMING OPTIONS

Program Setting 1: Service Indicator

The Service Indicator is used to predict when the filter will need 

cleaning (electronic air cleaners) or replacement (media air cleaners).

The Service Indicator automatically calculates the service interval 

based on the pollution level selected and the fan speed. If the filter 

becomes clogged the led • and •••• will flash each time the air cleaner 

is turned on.

Pollution level guidelines for establishing setting:

• LOW DUTY: general pollution without tobacco smoke

•• MEDIUM DUTY: moderate tobacco smoke concentrations

••• HEAVY DUTY: high tobacco smoke concentrations

•••• EXTREME DUTY: extremely high tobacco smoke concentrations

To select the pollution level:

•  Press PROGRAM; you are in the program mode  and STANDBY

  led will flash once every two seconds.

•  Default: OFF (all leds off).

•  Press 

: led • (LOW) will light up, meaning you’ve set the pollution 

  level to LOW DUTY.

•  Press 

: led •• (MEDIUM) will light up, meaning you have set the

  pollution level to MEDIUM DUTY.

•  Press 

: led ••• (HIGH) will light up, meaning you have set the 

  pollution level to HEAVY DUTY.

•  Press 

: led •••• (TURBO) will light up, meaning you have set the 

  pollution level to EXTREME DUTY.

•  If you want to go back to one of the previous pollution levels, 

  press 

t

.

•  Press PROGRAM to confirm setting 1 and to go to setting 2.

Program Setting 2: Resetting the Service Indicator

The indicator needs to be reset when the media filter is changed

out. If led • and led •••• are flashing, it is time to change the filter(s) 

and to reset the indicator.

To Reset:

•  Press PROGRAM: you are in the program mode 2 and the

  STANDBY led will flash twice every two seconds.

•  Default: OFF (all leds are off).

•  If the indicator is programmed (setting ), you will see all the leds 

  switched on in setting 2, provided the Service Indicator is in use 

  for a while.

•  Reset Service Indicator: press OFF (all leds are off).

•  Press PROGRAM: all user settings are saved and the air cleaner 

  is back in normal control.

Program Setting 3: Maximum fan speed for Air Quality
Analyzer (AUTO mode)

It is not possible to go directly to setting 3.

If the panel button (>> ) and then the PROGRAM key are pressed

simultaneously before confirming setting 2, you’re in setting 3 and 

STANDBY led will flash three times every two seconds.

ComfortPro Air Cleaner Programming Options

Program Setting 1: Service Indicator
Program Setting 2: Resetting the Service Indicator
Program Setting 3: Maximum fan speed for Air Quality Analyzer (AUTO mode)
Program Setting 4: Manual lock
Program Setting 5: Voltage output for maximum
Program Setting 6: Maximum fan speed IR control/panel button
Program Setting 7: Sensitivity adjustment Air Quality Analyzer
Program Setting 8: Time without high voltage after service (Electronic Air Cleaners only)
Reset to factory default

Adjusting the maximum fan speed for the optional Air Quality

Analyzer is very convenient for meeting rooms and open plan offices.

•  Default: •••• (TURBO).

•  Press 

t

 and so on to go to the desired maximum fan speed.

•  Press PROGRAM: confirm setting 3 and go to setting 4.

Program Setting 4: Manual lock

In setting 4 STANDBY led will flash four times every two seconds.

Blocking the panel button (>> ), to ensure that non-authorised

people cannot control the air cleaner.

•  Default: unlock; no leds are burning.

•  Press 

t

 or 

: lock; led • (LOW) is burning.

•  Press 

t

 or 

: unlock; led • (LOW) is off.

•  Press PROGRAM: confirm setting 4 and go to setting 5.

Program Setting 5: Voltage output for maximum
efficiency (Electronic Air Cleaners only)

In setting 5 STANDBY led will flash five times every two seconds.

This setting can be used to lower the efficiency (up to 10% at

low HV). This will increase the time between cleaning intervals.

•  Default: high HV level (7600 V); leds •, •• and ••• are burning.

•  Press 

t

: medium HV level (7300 V); leds £ and ££ are burning.

•  Press 

t

: low HV level (700 V); led • is burning.

•  Press 

: to increase efficiency again up to maximum HV level 

  (7900 V); leds •, ••, ••• and •••• are burning.

•  Press PROGRAM: confirm setting 5 and go to setting 6.

Program Setting 6: 
Maximum fan speed IR control/panel button

In setting 6 STANDBY led will flash six times every two seconds.

Adjusting the maximum fan speed for IR-control/panel button is very 

convenient for air cleaners installed in meeting rooms and open plan 

offices.

•  Default: •••• (TURBO).

•  Press 

t

 and so on to go to the desired maximum fan speed.

•  Press PROGRAM: confirm setting 6 and go to setting 7.

Program Setting 7: 
Sensitivity adjustment Air Quality Analyzer

In setting 7 STANDBY led will flash seven times every two

seconds.

Setting the sensitivity of the Air Quality Analyzer. The more

sensitive, the quicker the reaction to changes in pollution level.

•  Default: OFF (all leds are off), meaning the lowest sensitivity

•  Press 

: led • (LOW) will light up, meaning you’ve set the pollution 

  sensitivity to low.

•  Press 

: led •• (MEDIUM) will light up, meaning you have set the 

  pollution sensitivity to medium.

•  Press 

: led ••• (HIGH) will light up, meaning you have set the 

  pollution sensitivity to heavy.

•  Press 

: led •••• (TURBO) will light up, meaning you have set the 

  pollution sensitivity to extreme.

•  If you want to go back to one of the previous pollution sensitivity, 

  press 

t

.

•  Press PROGRAM to confirm setting 7 and go to setting 8.