White Rodgers 37-6186B Скачать руководство пользователя страница 1

COMFORT-SET 90

®

 SERIES

HEAT PUMP 

INSTALLATION/CONFIGURATION

This White-Rodgers Automatic Setback
Digital Thermostat uses microcomputer
technology to provide precise time and

1F94-371: 7 Day programming; residen-

tial applications

ELECTRICAL  DATA

Electrical Rating:

20 to 30 VAC, 50/60 Hz with common
0.05 to 1.5 Amps per terminal
2.5 Amps maximum total load (all
terminals combined)

INSTALLATION

WHITE-RODGERS

Part No. 37-6186B

Replaces 37-6186A

0121

DESCRIPTION

SPECIFICATIONS

temperature control. This thermostat offers
the flexibility to design heating and cooling
programs that fit building needs. This

Standard Systems:

Single-stage or two-stage compressor
heat pump.

THERMAL DATA

Setpoint Temperature Range:

45

°

 to 99

°

F (7

°

 to 37

°

C)

Operating Ambient Temperature:

32

°

 to 110

°

F (0

°

 to 43

°

C)

Operating Humidity Range:

90% non-condensing max.

Shipping Temperature Range:

-4

°

 to 149

°

F (-20

°

 to 65

°

C)

PRECAUTIONS

Do not short out terminals on gas valve
or primary control to test. Short or
incorrect wiring will damage thermostat
and could cause personal injury and/or
property damage.

Do not use on circuits exceeding
specified voltage. Higher voltage will
damage thermostat and could cause
shock or fire hazard.

Thermostat installation and all compo-
nents of the system shall conform to
Class II circuits per the NEC code.

To prevent electrical shock and/or
equipment damage, disconnect electric
power to system at main fuse or circuit
breaker box until installation is
complete.

Read all instructions thoroughly before
beginning installation.

CAUTION

!

WARNING

!

This thermostat is intended for use with a
low voltage system. Do not use on a line
voltage system.

Do not exceed ratings shown in the Specifi-
cations section, above. If in doubt about the
electrical ratings of your heating/cooling
system, have it inspected by a qualified
heating and air conditioning contractor or
licensed electrician.

All wiring must conform to local and
national electrical codes and ordinances.

This control is a precision instrument, and
should be handled carefully. Rough handling
or distorting components could cause the
control to malfunction.

NOTE

thermostat is adaptable to most 24 volt
residential forced air heat pump systems with
electric or fossil fuel auxiliary.

Содержание 37-6186B

Страница 1: ...uld cause personal injury and or property damage Do not use on circuits exceeding specified voltage Higher voltage will damage thermostat and could cause shock or fire hazard Thermostat installation a...

Страница 2: ...rom the old thermostat one at a time DO NOT let the wires fall back into the wall Install the new thermostat using the follow ing procedures ATTACH BASE TO WALL Remove packing material from the thermo...

Страница 3: ...tric backup Heat Pump 1 Emergency mode first stage 24 Volt Common 24 Volt Hot Emergency mode 3rd stage Heat mode 3rd stage Emergency mode 2nd stage E2 Emergency mode constant output P All other modes...

Страница 4: ...ill change to show the first item on the Installer menu multi stage heat pump selection Use the following text along with the Installer table on page 5 to guide you through the menu Once in the menu y...

Страница 5: ...air Selects Remote Sensor B connected to SB if ON Selects Remote Sensor C connected to SC if ON When OFF disables local sensor if a remote sensor is enabled PROGRAM RUN SET and SET hold for approx 3...

Страница 6: ...g this period the compressor will not be energized If the system has short cycle protection this item should not need to be enabled How ever if your system does not have short cycle protection turn CO...

Страница 7: ...ION If your system does not have a G terminal connection skip to Heating System section 1 Turn power on to the system 2 Press PROGRAM RUN 3 Press FAN until FAN ON is displayed The fan should begin to...

Страница 8: ...default programs and configuration Removing power from the thermostat will not reset it because the default settings are maintained in permanent memory Before resetting the thermostat you may want to...