background image

OPERATION GUIDE

7 Day Multi-stage Electronic Digital
Thermostat with Programmable Fan

1F95W-80

Operator: Save this booklet for future use!

WHITE-RODGERS

Содержание 1F95W-80

Страница 1: ...OPERATION GUIDE 7 Day Multi stage Electronic Digital Thermostat with Programmable Fan 1F95W 80 Operator Save this booklet for future use WHITE RODGERS...

Страница 2: ...ment at the address shown on the back cover of this booklet Your new Digital COMFORT SET II Multi stage Thermostat uses the technology of a solid state microcomputer to provide precise time temperatur...

Страница 3: ...ND ANSWERS 32 In This Guide YOUR NEW THERMOSTAT S FEATURES 4 OPERATING YOUR THERMOSTAT 5 PARTS OF THE THERMOSTAT The Back Of the Thermostat Body The Display The Thermostat Buttons OPERATING FEATURES P...

Страница 4: ...continuous set point time and room temperature Adjustable cycle times 9 volt Energizer alkaline battery backup Compressor short cycle protection Blower delay in the cooling cycle Up to 2 stages of hea...

Страница 5: ...ult in equipment damage and or personal in jury OPERATINGYOURTHERMOSTAT The subbase is attached to the wall but you can remove the thermostat body for easy program ming To remove the thermostat body f...

Страница 6: ...program to be lost the thermostat will automatically return to the factory programmed temperatures 64 F heating and 82 F cooling when power is restored You must reprogram the thermostat if this happe...

Страница 7: ...he buttons other than and are located behind the thermostat door To open the door use your fingernail in the indentation at the top center of the door Pull the door out then swing the door down on its...

Страница 8: ...is displayed when the setpoint temperature displayed at the far right is the occupied heating or cooling temperature depending on mode U is displayed when the unoccupied heating or cooling temperatur...

Страница 9: ...9 O U FAN AUTO FAN ON BATTERY 5 DAY FAN AUTO VIEW PRGM RUN PRGM FAN ON AUTO HOLD COPY VIEW TEMP SET CLOCK ADV DAY SYSTEM HEAT OFF COOL AUTO TIME FWD TIME BACK 1 3 2 4 4 3 5 5 2 6...

Страница 10: ...s temperature setting 99 F or 37 C maximum The Thermostat Buttons 7 Sets the system mode HEATing OFF COOLing or AUTOmatic changeover 8 Selects fan operation see 5 above This button is also used to pro...

Страница 11: ...SYSTEM HEAT OFF COOL AUTO TIME FWD TIME BACK 17 9 10 11 12 13 14 15 8 7 16 18 18 Red indicator is lit when heating or cooling is in operation Yellow indicator is lit when the second stage of heating o...

Страница 12: ...e of 62 F and that during the next program period beginning at 6 00 AM you have programmed a temperature of 70 F The thermostat will automatically activate the heating system at about 5 00 AM so that...

Страница 13: ...rewdriver to move option switch 3 to the OFF down position Remove the battery and allow at least two minutes for the ther mostat to reset itself Replace the battery press SYSTEM HEAT OFF COOL AUTO unt...

Страница 14: ...ture at the selected temperature for two hours After two hours the thermostat will automatically revert to the program This feature will not work in the AUTO mode Therefore we do not recommend using t...

Страница 15: ...setting from 4 to 40 If the heat cycles are too short press TIME FWD to HOLD TEMPERATURE The thermostat can hold any temperature within its range for an indefinite period without reverting to the pro...

Страница 16: ...this feature works only when the thermostat is attached to the wall and 24 VAC power is present to the thermostat BACKLIT DISPLAY When you press any button on the thermostat the display is lit for app...

Страница 17: ...nuously during any given pro gram period regardless of the cycling of the heating or cooling system During programming after entering the time and SYSTEM INDICATOR LIGHTS The red indicator light comes...

Страница 18: ...n planning your program When heating cooling your building pro gramthetemperaturestobecooler warmer when the building is vacant or during peri ods of low activity During early morning hours the need f...

Страница 19: ...ss RUN PRGM to begin running the factory preset program If you want to change the preprogrammed times and temperatures do the following Determine the heating and cooling times and temperatures you wan...

Страница 20: ...y Tuesday Wednesday Thursday Friday Saturday Sunday Heating Cooling Schedule Plan NOTE Damper operation is linked to occupied or unoccupied temperature settings not time periods If you program an unoc...

Страница 21: ...occupied Cooling Temp Monday Tuesday Wednesday Thursday Friday Saturday Sunday SAMPLE Heating Cooling Schedule Plan 9 30AM 9 30AM 9 30AM 9 30AM 9 30AM 9 30AM 11 30AM 73 F 73 F 73 F 73 F 73 F 73 F 73 F...

Страница 22: ...designa tion AM begins at midnight PM begins at noon ENTERING YOUR PROGRAM Follow these steps to enter the heating cooling program you have selected We recommend that you remove the thermostat from t...

Страница 23: ...currently programmed HEAT O setting 3 Press either or to change the temperature to your selected HEAT O setting 5 Press SET CLOCK once The display will show the day of the week as an abbreviation MO f...

Страница 24: ...oling temperature COOL O 9 Press either or to change the temperature to your selected COOL O setting 10 Press VIEW TEMP once Press or to set your selected COOL U unoccupied cool ing setting 11 Press R...

Страница 25: ...e you want for Monday s occu pied heating period press or if you continue to press or the NOTE display will alternate between the HEAT O and HEAT U temperatures you previously selected Damper operatio...

Страница 26: ...ds and heating temperatures press RUN PRGM to begin program operation press VIEW PRGM Thecurrentlyprogrammedstart time and heating temperature for Monday s unoccupied heating period will be dis played...

Страница 27: ...REATTACHING THE THERMOSTAT TO THE SUBBASE 1 Press SYSTEM HEAT OFF COOL AUTO until COOL is displayed 2 Press VIEW PRGM once MO the abbreviation for Monday and the letter O representing the occupied coo...

Страница 28: ...fan to run continuously during Monday s occupied cooling period press FAN ON AUTO until PRG FAN is displayed 6 After selecting the desired cooling tempera ture for Monday s occupied cooling period pr...

Страница 29: ...s HOLD COPY once COPY will appear on the display A number from 1 to 7 will also appear representing the day you have se lected to copy Monday is 1 Tuesday is 2 9 After you enter or copy heating and co...

Страница 30: ...py any day s programming into any other day s program 7 Press RUN PRGM to begin program operation CHECK YOUR PROGRAMMING Follow these steps to check your thermostat programming one final time before b...

Страница 31: ...u may set option switch 4 for total keypad lockout programming instructions to correct the er ror you can change any part of your pro gram while you are reviewing it 6 Press RUN PRGM 7 Press SYSTEM HE...

Страница 32: ...e The display will change to the time temperature mode To resume programming press VIEW PRGM and ADV DAY until you return to the point where you stopped programming Then you may continue to program th...

Страница 33: ...ely press SYSTEM HEAT OFF COOL AUTO until OFF is displayed and replace the ther mostat on the wall Then press SYSTEM HEAT OFF COOL AUTO until HEAT COOL etc is displayed and press a cooling temperature...

Страница 34: ...mple if 70 F is your lowest selected cooling temperature you cannot select a heating temperature any higher than 69 F If such a conflict exists you must set the lowest cooling temperature higher in or...

Страница 35: ...the next program period See OPERATING YOUR THERMOSTAT 8 The display is flashing BATTERY What does this mean The 9 volt battery installed in the thermostat is low and should be replaced with a fresh 9...

Страница 36: ...begin running See OPERATING YOUR THERMOSTAT 11 Why does the blower fan keep running after the system has turned off The fan is programmed to run continu ouslyduringthisperiod SeePROGRAM MING YOUR THER...

Страница 37: ...ng powered by a 24 VAC source If power is lost or if the thermostat is removed from the wall the program will be maintained for 13 Between heating and cooling seasons I want to turn my system off Can...

Страница 38: ...otlose your programming After installing a new battery follow the procedures in CHECK YOUR PROGRAMMING to determine whetheryourprogrammingwasmaintained Ifthethermostatretainsprogramming press SYSTEM H...

Страница 39: ...39 NOTES...

Страница 40: ...OAD ST LOUIS MISSOURI 63123 5398 If you need further information on programming or operation please write to us at White Rodgers Division Emerson Electric Co 9797 Reavis Road St Louis MO 63123 5398 At...