Installation

2

Wiring Connections

2

Thermostat Quick Reference

3

Installer Configuration Menu

4

Operating Your Thermostat

6

Programming

6

Troubleshooting

8

www.white-rodgers.com

90 Series Blue Universal Thermostat with

90 Series Blue Universal Thermostat with

90 Series Blue Universal Thermostat with

90 Series Blue Universal Thermostat with

90 Series Blue Universal Thermostat with

Automatic Heat/Cool Changeover Option

Automatic Heat/Cool Changeover Option

Automatic Heat/Cool Changeover Option

Automatic Heat/Cool Changeover Option

Automatic Heat/Cool Changeover Option

PART NO. 37-6735A

0544

Single Stage, Multi-Stage, Heat Pump

Installation and Operating Instructions for Model:

APPLICATIONS

Description

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with Aux. or Emergency Heat)

Yes

Systems with up to 3 Stages Heat, 2 Stages Cool

Yes

Heat Only Systems

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

No

THERMOSTAT APPLICATION GUIDE

1F95-1271 Touchscreen Thermostat

SPECIFICATIONS

Electrical Rating:

Battery Power  . . . . . . . . . . . . . . . . . . . . . . . . .

mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire  . . . . . . . . . . . . . . . . . . . . . . . .

20 to 30 VAC

Terminal Load  . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.5 A per terminal, 2.5A maximum all terminals combined

Setpoint Range  . . . . . . . . . . . . . . . . . . . . . . . . . . .

45 to 99°F (7 to 32°C)

Differential (Single Stage)  . . . . . . . . . . . . . . . . . . .

Heat 0.6°F; Cool 1.2°F

Differential (Multi-Stage)  . . . . . . . . . . . . . . . . . . . .

Heat 0.6°F; Cool 1.2°F

Differential (Heat Pump)  . . . . . . . . . . . . . . . . . . . .

Heat 1.2°F; Cool 1.5°F

Operating Ambient  . . . . . . . . . . . . . . . . . . . . . . . . .

32° to +105°F (0 to +41°C)

Operating Humidity  . . . . . . . . . . . . . . . . . . . . . . . .

90% non-condensing max.

Shipping Temperature Range  . . . . . . . . . . . . . . . .

-4 to +150°F (-20 to +65°C)

Dimensions Thermostat  . . . . . . . . . . . . . . . . . . . . .

4.6"H x 5.9"W x 1.2"D

To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.

CAUTION

!

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this
product may replace a product that contains mercury.

Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of  a product containing mercury or a sealed
container of  spilled mercury, place it in a suitable shipping
container and send it to:

White-Rodgers
2895 Harrison Street
Batesville, AR 72501

Index

Page

Model

Programming Choices

1F95-1271

Non-Programmable 5/1/1 Day

7 Day

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.

Содержание 1F95-1271

Страница 1: ...put Hardwire 20 to 30 VAC Terminal Load 1 5 A per terminal 2 5A maximum all terminals combined Setpoint Range 45 to 99 F 7 to 32 C Differential Single Stage Heat 0 6 F Cool 1 2 F Differential Multi St...

Страница 2: ...attached Disconnect the wires from the old thermostat one at a time Do not let wires fall back into the wall Installing New Thermostat 1 Pull the thermostat body off the thermostat base Forcing or pry...

Страница 3: ...ld At is displayed when the thermostat is in a temporary HOLD mode 10 Hours and Days displays during steps in installer configuration 9 Hold Until indicates the time when a temporary hold period will...

Страница 4: ...17 FA Heat On OFF If HP or MS selected in item 1 selects Heat Fast second stage On or Off 20 18 FA Cool On OFF If HP or MS selected in item 1 selects Cool Fast second stage On or Off 21 19 000 Change...

Страница 5: ...f your setpoint temperature when using this feature The temperature limit icon will flash if an attempt is made to adjust the temperature beyond the range selected 16 Cool Temperature Limit Range This...

Страница 6: ...r mode Set Current Time and Day 1 Press Menu and then Set Time button once The display will show the hour only 2 Press and hold either the or key until you reach the correct hour and AM PM designation...

Страница 7: ...ogramming see configura tion section Factory settings are listed on Monday Saturday and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below t...

Страница 8: ...safety devices that shut down when a lock out condition occurs If the heat works intermittently contact the furnace manufacturer or local HVAC service person for assistance Diagnostic Set SYSTEM Swit...

Отзывы: