background image

80 Series Thermostat 

Wiring Diagrams for 1F83-0422 & 1F85-0422

Single Stage, Multi-Stage, Heat Pump

Heat Pump Connections

If you do not have a heat pump system, refer to fi gures 2 & 3.
Refer to equipment manufacturers’ instructions for specifi c system 
wiring information.
You can confi gure the thermostat for use with the following heat 
pump systems.

Figure 1 – Heat Pump Systems

HEAT PUMP TYPE 1 (HP 1). 

Single stage compressor system; gas 

or electric backup.

NOTE: If your system 

does not provide an E 

connection, jumper W2 to 

W/E to use the Auxiliary 

Heat in the Emergency 

Mode.

* Common connection

required for fault or

malfunction indication.

Single Stage and Multi-Stage Connections

Refer to equipment manufacturers’ instructions for specifi c system 
wiring information.
This thermostat is designed to operate a single-transformer or two-
transformer system.
You can confi gure the thermostat for use with the following fossil fuel 
systems:

SINGLE STAGE (SS 1)

 gas, oil or electric.

MULTI-STAGE (MS 2)

 gas, oil or electric.

After wiring, see INSTALLER CONFIGURATION section for proper 
thermostat confi guration.

Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer

* Common connection

required for fault or

malfunction indication.

www.white-rodgers.com

PART NO. 37-6895B

Replaces 37-6895A

0825

Heat Pump 1

(HP1)

O

Energized in

Cool Mode

B

Energized in

Heat, Off,

Emergency

Mode

No
Output

Heat and
Cool Mode
1st Stage
(Compressor)

Blower/
Circulator
Fan Energized
on Call for
Heat or Cool.
Set Elect/Gas
Option for
Emergency
Mode

Heat Mode
2nd Stage.
Emergency
Mode 2nd
Stage

Emergency
Mode
1st Stage

Optional*

24 Volt

(Com-

mon)

Fault Indicator
or
System
Malfunction
Switch

24 Volt
(Hot)
Cool

System

Y

W/E

C

L

RC

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

24 Volt
(Hot)
Heat

RH

Jumper

Y2

W2

G

Jumper

Comfort Alert II Module 

or Similar System

Malfunction Module

O/B

Single
Stage 1

(SS1)

Multi-
Stage 2

(MS2)

O

Energized Constantly

in

Cool Mode

B

Energized Constantly

in Heat, Off,

Emergency

Mode

No
Output

Cool
Mode
2nd
Stage

Cool Mode
1st Stage

Blower/
Circulator
Fan Energized
on Call for
Cool (and
Heat if
configured
for Electric
Heat)

No Output

Heat Mode
2nd Stage

Heat
Mode
1st Stage

Optional*

24 Volt

(Com-

mon)

24 Volt
(Hot)
Cool

System

Y

G

W/E

C

L

RC

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

24 Volt
(Hot)
Heat

RH

Y2

W2

Jumper

Fault
Indicator
or
System
Malfunction
Switch

Comfort Alert II Module 

or Similar System

Malfunction Module

O/B

Отзывы: