background image

Installation Instructions for

Heating & Air Conditioning

1F72

5/2 Day Programmable

Heat Pump Thermostat

CONTENTS

Preparations .................................................. 1

Thermostat Details ........................................ 1

Removing Old Thermostat ......................... 1-2

Mounting and Wiring .................................. 2-3

Check Thermostat Operation ..................... 4-5

Programming your Thermostat .................. 6-7

Specifications ................................................ 7

Troubleshooting ......................................... 7-8

PREPARATIONS

THERMOSTAT DETAILS

REMOVING OLD THERMOSTAT

Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.

1. Remove Old Thermostat:  A standard heat/cool thermostat

consists of three basic parts:

a. The cover, which may be either a snap-on or hinge type.

b. The base, which is removed by loosening all captive screws.

c. The switching subbase, which is removed by unscrewing

the mounting screws that hold it on the wall or adaptor plate.

2. Shut off electricity at the main fuse box until installation is

complete. Ensure that electrical power is disconnected.

3. Remove the front cover of the old thermostat. With wires still

attached, remove wall plate from the wall. If the old thermostat
has a wall mounting plate, remove the thermostat and the wall
mounting plate as an assembly.

4. Identify each wire attached to the old thermostat using the

labels enclosed with the new thermostat.

5. Disconnect the wires from the old thermostat one at a time. DO

NOT LET WIRES FALL BACK INTO THE WALL.

6. Install new thermostat using the following procedures.

To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.

CAUTION

!

Printed in U.S.A.

PART NO. 37-6498A

0342

WHITE-RODGERS
EMERSON ELECTRIC CO
ST. LOUIS, MISSOURI

www.white-rodgers.com

Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage.

Assemble tools required as shown below.

YOUR THERMOSTAT  REPLACES

1

2

3

WIRE CUTTER/STRIPPER

Description

Heat Pump (No Aux or Emergency Heat)

Yes

Heat Pump (with Aux or Emergency Heat)

Yes

Standard Heat & Cooling Systems

No

Standard Heat Only Systems

No

Millivolt Heat Only Systems – Floor or Wall Furnaces

No

Standard Central Air Conditioning

No

Gas or Oil Heat

No

Electric Furnace

No

Hydronic (Hot Water) Zone Heat – 2 Wires

No

Hydronic (Hot Water) Zone Heat – 3 Wires

No

HAND OR POWER 
DRILL WITH 3/16 INCH 
DRILL BIT, IF NEEDED

FLAT BLADE SCREWDRIVER

SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL— 

THERMOSTAT DOES NOT NEED TO BE LEVEL TO WORK PROPERLY

Figure 1. Thermostat base

W905

Clip for

Slow Cycle

W904

Clip for

Celsius

W903

Clip to

Disable

EMR

Feature

Mounting

hole

W906 for Emergency

Heat Second Stage

Fan Control

O/B 

Terminal

Switches 

Selection

Mounting

hole

Содержание 1F72

Страница 1: ...ct the wires from the old thermostat one at a time DO NOT LET WIRES FALL BACK INTO THE WALL 6 Install new thermostat using the following procedures To prevent electrical shock and or equipment damage...

Страница 2: ...t off the base Forcing or prying on the thermostat will cause damage to the unit 2 Connect wires beneath terminal screws on base using appro priate wiring schematic see figs 2 through 4 3 Place base o...

Страница 3: ...FF If safety circuits are in only one of the systems remove the transformer of the system with NO safety circuits NOTE Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency...

Страница 4: ...t setting above room tempera ture The Aux heating system will begin to operate The Flame icon will display flashing to indicate that the Aux system is operating 3 Press to adjust the thermostat below...

Страница 5: ...OFF 4 OFF Select display backlight OFF or ON HOLD dL ON Not available on earlier models Press HOLD to advance to next item or TIME to move backwards to previous item CHECK THERMOSTAT OPERATION CONTINU...

Страница 6: ...during each period You may also want to look at the sample program table to get an idea of how the thermostat can be programmed Entering Your Program Follow these steps to enter the heating and coolin...

Страница 7: ...ress RUN 4 Move SYSTEM switch to COOL position 5 Repeat step 2 to check cooling temperatures 6 Press RUN to begin program operation YOURTHERMOSTATISNOWCOMPLETELYPROGRAMMED AND READY TO AUTOMATICALLY P...

Страница 8: ...bed above If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replac...

Отзывы: