PILOT FLAME CHARACTERISTICS
Figures 13, 14 and 15 show a correct pilot flame pattern. The correct
flame will be blue and will extend beyond the thermocouple. The
flame will surround the thermocouple just below the tip. A slight
yellow flame may occur where the pilot flame and main burner
flame meet. Figures 16, 17 and 18 show an incorrect pilot flame
pattern. The incorrect pilot flame is not touching the thermocouple.
This will cause the thermocouple to cool. When the thermocouple
cools, the heater will shut down.
Correct Pilot Flame Pattern
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
THERMOPILE
PILOT
Millivolt Pilot, Figure 13
PILOT
THERMOCOUPLE
(NATURAL)
THERMOCOUPLE
(LPG)
Hydraulic Thermostat Pilot, Figure 14
PILOT
SENSOR
IGNITOR
Intermittant Pilot, Figure 15