Страница 2: ... manual is accurate WhisperKOOL is not responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vinothèque and WhisperKOOL are registered trademarks and ECE is a trademark of WhisperKOOL All rights reserved Mention of third party products is for informational pur...

Страница 3: ... Customer 3 About the WhisperKOOL 2500 3 Liquid Measuring Thermometer 4 System Operation 5 Controller Operation 7 Testing the Refrigeration Unit 10 Cool Down Period 10 Normal Operation and Maintenance 11 Troubleshooting 12 Installation Terms and Conditions 13 Technical Assistance 15 ...

Страница 4: ...WHISPERKOOL 2500 QUICK REFERENCE GUIDE WK 2500 Contents 18 1 4 x 3 8 pan head screws 1 1 8 x 8 ft piece of foam tape BOTTLE PROBE AIR DEFLECTOR CONTROLLER EVAPORATOR FAN SPEED SWITCH BOTTLE PROBE CONNECTOR EVAPORATOR COIL MOUNTING FLANGE ...

Страница 5: ...ause damage to the compressor and negatively affect cooling A dedicated 20 amp circuit is highly recommended for optimum operation Tripped breakers and deficient performance may occur if other devices are pulling power from the same circuit Do not use a Ground Fault Interrupter GFI with this product The cooling unit will draw more amperage than the GFI will allow It is recommended that you plug yo...

Страница 6: ...probe into a level rack space Avoid pulling too much on the probe cord as it may become disconnected which would lead to inaccurate temperature readings The WhisperKOOL system is based on the temperature of the wine It is ideal to place the probed bottle midway in the racking so that it is not near cold supply air Do not be misled by ambient temperatures that are read from the outside of the cabin...

Страница 7: ...pacitor Condenser Blower Compressor BLUE WHITE BLACK BLACK BROWN BLACK WHITE POWER SUPPLY 115 VAC 60 Hz 20A POWER CORD GREEN GREEN BLUE GREEN WHITE BLUE 1 2 3 4 5 BROWN WHITE HEATING ELEMENT SNAP DISK 1 2 3 4 5 BLUE WHITE BLACK 1 2 3 4 5 WHITE LM W BLUE BLUE WHITE GREEN 3 2 1 YELLOW WHITE NC C NO 3 4 2 7 8 6 1 0 COIL LM W 1 2 3 4 5 1 2 3 4 5 BLACK WHITE GREEN BLACK BLACK BROWN BROWN WHITE BLUE BRO...

Страница 8: ...he compressor and allow the evaporator and condenser fans to run to evaporate any frost accumulation on the coil The compressor will remain off until the evaporator coil reaches 40 F or for a maximum of ten minutes The unit will then return to normal operation If the evaporator is not above 26 F after the Anti Frost Cycle has ended the red error light will display in the upper right corner The ala...

Страница 9: ...allow the exhaust side of the cooling unit to operate correctly As the unit cools on the inside condensing refrigerant creates heat which will need to dissipate away from the unit on the outside Some units have an exhaust fan mounted on top of the cabinet which forces air away from the unit vertically In order to avoid disrupting the ventilation do not place anything on top of the cabinet WhisperK...

Страница 10: ...utton again While the current temperature setting is displayed press the up or down arrows to change set point When the display shows the desired temperature setting press and release the set button again Accessing Alarm Codes Press and Release the set button While AL is displayed press and release the set button SNOWFLAKE Steadily Illuminated The unit is in cooling mode and the compressor is runn...

Страница 11: ...nit Faulty bottle probe connection 1 Check bottle probe attachment at circular connector 2 Check bottle probe connection at the back of controller Defective bottle probe Replace the bottle probe E2 Faulty evaporator probe connection Check evaporator probe connection at the back of controller Defective evaporator probe Replace the evaporator probe E3 Faulty condenser probe connection Check the cond...

Страница 12: ...g correctly contact WhisperKOOL s Customer Service Department at info whisperkool com We will work with you to diagnose the problem and promptly resolve it LOADING BOTTLES AND COOL DOWN PERIOD Loading Bottles The cabinet may settle slightly based on the weight of all the bottles It is best to spread the loading of bottles evenly throughout the cabinet starting on the bottom first This will prevent...

Страница 13: ...ndenser filter every three months WhisperKOOL recommends vacuuming of the condenser fins located in the rear of the cabinet every three months A partially obstructed condenser dramatically reduces the efficiency of the cooling unit Monthly Check filters Check for unusual noise or vibration Quarterly Clean filters o Remove the filter covering the coil o Wash with warm water o Dry off filter by shak...

Страница 14: ...rage temperature Ambient room temperature is too warm Lower the temperature in the room Inadequate ventilation Assure proper space above behind and on the side of the unit Do not set anything on top Door gasket not sealing properly See cabinet owner s manual Not cooling Thermostat setting May be set too warm lower the set temperature Thermostat not operating correctly Test unit with bypass plug Co...

Страница 15: ...LABOR repair or replace at WhisperKOOL s sole option the Product at no charge to the End User and 2 PARTS supply at no charge to the End User new or rebuilt replacement parts for the Product in exchange for the return of defective parts and 3 FREIGHT cover normal ground freight charges for parts and in the event the Product is not repairable in the field cover normal ground freight charges within ...

Страница 16: ... the End User s responsibility to secure safe haven storage for ANY AND ALL items that are being kept and stored in the End User s wine cellar including any Product WhisperKOOL takes no responsibility for the safety and preservation of the aforementioned items in the event that the environment becomes unsuitable to maintain a proper storage environment 6 SALES AND USE TAX WhisperKOOL only collects...

Страница 17: ...e model and serial number of your WhisperKOOL unit Location of the system and installation details such as ventilation construction of your wine cellar and room size Contact WhisperKOOL Customer Service 1738 E Alpine Ave Stockton CA 95205 www WhisperKOOL com E mail support whisperkool com Fax 209 466 4606 For WhisperKOOL 2500 Check Right side of unit on a silver sticker Model _____________________...