Страница 1: ...RSION 3 OWNER S MANUAL The Coolest Thing In Wine Storage NOTICE To activate the split system warranty the installing certified HVAC R service tech must complete the split system warranty checklist and send back to CellarCool ...

Страница 2: ...responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vinothèque and WhisperKOOL are registered trademarks and ECE is a trademark of WhisperKOOL All rights reserved Mention of third party products is for informational purposes only and constitutes neither an e...

Страница 3: ...uick Reference Guide System 5 Display Layout Unit Specifications 6 Preparing the Wine Cellar 7 Liquid Measuring Thermostat Bottle Probe 10 System Operation 11 Controller Functions 13 Troubleshooting Guide 18 Maintenance Schedule 20 Technical Assistance Accessories 21 Installation Terms Conditions 22 ...

Страница 4: ... designed for one purpose only to maintain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines This system produces minimal in cellar noise and has the most lenient exhaust requirements An exterior housing is required for outdoor condensing unit installations How Does the Cooling System Work Similar to the air conditioning systems used for homes the ...

Страница 5: ...ng unit 4 You are REQUIRED to install a drain line to remove condensation from the evaporator unit fan coil unit 5 The warranty is not active until a warranty checklist has been received reviewed and approved 6 The system is intended for use in properly designed and constructed wine cellars Hire a professional wine storage consultant with a valid contractor s license to build your wine cellar 7 Wh...

Страница 6: ...epancy or visual damage on the bill of lading before signing Allow the condensing unit to sit for 24 hours prior to start up The condensing unit can be placed in the installation location piped and evacuated during this time Note WhisperKOOL units are manufactured in the USA and tested prior to shipment Review the packing slip to verify contents Check the model number to ensure it is correct Check...

Страница 7: ...de View Rear Side View Filter grille Evaporator unit fan coil unit INSIDE CELLAR Option 2 THROUGH THE WALL Option 1 Knockout for wiring Line set knockout Knockout for drain line Knockout for wiring Mounting keyholes 4 Line set knockout Knockout for drain line REAR VIEW ...

Страница 8: ...D Drain Line 1 2 ID clear plastic tubing not included Installation Evaporator unit fan coil unit is installed in the cellar The condensing unit is installed up to 100 line feet away and in accordance with the installation specifications found in the technician s manual Thermostat Digital display Temp Delta 55 F temperature differential maintains proper cellar temperature when exhaust environment d...

Страница 9: ...e R value the more resistant the insulation is to conducting heat and the more consistent your wine cellar s temperature will be Using higher R values in insulation will lower your operating costs and WhisperKOOL unit run time R 13 is the recommended minimum R 19 is preferred for interior cellar walls and R 30 for ceilings and exterior walls Vapor Barrier Water vapor creates its own pressure separ...

Страница 10: ...n the room will create a consistently cool environment by capturing the warm air and replacing it with cool air Mounting the unit low in the room will result in a temperature variation in the room due to the unit s inability to draw warm air from the ceiling of the cellar to the unit itself and cold air settling to the floor Door and Door Seal An exterior grade 13 4 door must be installed as a cel...

Страница 11: ...it If ventilation is inadequate the exhaust will heat up the area or room and adversely affect the system s ability to cool In some cases it may be advisable to install a vent fan to dissipate heat within the exhaust area on the condensing side of the system However you must have a fresh air inlet as well Note If you are unsure about having adequate ventilation in your install location please cont...

Страница 12: ... Place bottle probe securely into bottle as seen in Figure 1 4 Place bottle off to the side of the unit in your wine cellar with the probe level 5 To ensure a consistent temperature place bottle probe approximately three 3 feet away from the air output and not in the flow of the air It is recommended that the bottle be placed in a central location of your wine cellar Avoid pulling too much on the ...

Страница 13: ... the pressure in the refrigeration system to equalize prior to starting the compressor Once the solenoid relay is de energized the controller must wait five minutes before reenergizing the relay This prevents the compressor from repeatedly turning off and on If the unit is calling for cooling during this time the compressor icon will blink indicating that cooling is needed but the controller is wa...

Страница 14: ...an is on Anti Frost Cycle running Alarm is present F View Change Set Point Enter User Menu hold for 3 sec Unlock Button hold for 1 sec Scroll Button Change Set Point 55 F Power On Off Scroll Button Change Set Point Return to Previous Menu DISPLAY LAYOUT ...

Страница 15: ... to navigate through menus and adjust parameters such as set point Fon FOF etc SET To change the set point press the SET button When SEt is displayed on the screen press the SET button once more Use the UP and DOWN ARROW buttons in order to change the value until the desired set point is reached The SET button allows you to view the set point evaporator temperature bottle tempera ture alarms and t...

Страница 16: ...and the condensing unit is running DRIPPING SNOWFLAKE The unit is undergoing an Anti Frost Cycle See System Operation page for further details FAN The evaporator fan is running ALARM The alarm icon is shown when the unit encounters an issue that needs attention Alarm codes are explained on the following page All temperature related alarms are blocked for the first 10 hours after the unit is plugge...

Страница 17: ...larm codes will not be displayed on the home screen However the alarm icon will be displayed in the event of an alarm The alarms can be viewed in the Set Menu s ALr folder EA Unit is not draining properly 1 Check to see that the unit is level if not level it 2 Verify that the drain line is not clogged if so clear obstruction 3 Ensure that the condensate pump is operating NOTE If the drain line is ...

Страница 18: ... be adjusted as most properly constructed wine cellars retain an ample amount of humidity during the fan off cycle If however you wish to decrease the duration of the fan off cycle in order to increase the wine cellar s relative humidity you can adjust this setting in the User Menu Fon fan on The fan on time is preset to zero minutes This keeps the relative humidity of the wine cellar at a stable ...

Страница 19: ...www whisperkool com Page 17 Mini Split NOTES ...

Страница 20: ... for cooling Lower set point Faulty thermostat or wiring Call Customer Service at 1 800 343 9463 Cellar temperature is too warm Possible cause Solution The temperature of the room to which the condensing unit exhausts exceeds 110 F Intake temperature must drop below 110 F The system is undersized for the cellar Order correct size system There is something blocking the supply and or return air on t...

Страница 21: ...n the display the system is going through an Anti Frost Cycle No action is required 2 If the system is not maintaining the correct cellar temperature this may be due to a dirty evaporator filter or coil 3 Call the installing technician to troubleshoot as the system may be low on charge or require an adjustment to the TXV Compressor and or starting components faulty Please contact the installing te...

Страница 22: ...sel Quarterly 1 Use a vacuum with brush attachment to clean the evaporator coil be careful not to crush coil fins when cleaning 2 Remove the evaporator filter and clean with warm water 3 Ensure the condensing unit is free of debris and dust 4 Have a certified HVAC R technician service the condensing unit and clean the condenser coil Annually 1 Inspect for corrosion 2 Check wiring connections and i...

Страница 23: ...05 www whisperkool com Email support whisperkool com Phone 209 466 9463 US Toll Free 1 800 343 9463 Fax 209 466 4606 WhisperKOOL offers accessories to enhance and customize your wine cooling unit Exterior Housing Protects the condensing unit from the weather elements when the unit is located outside Condensate Pump Kit The condensate pump kit is designed as an automatic condensate removal pump for...

Страница 24: ...e approved by WhisperKOOL to activate the Limited Warranty If the Split Startup Checklist is approved Purchaser will be sent activation approval documents and will start receiving the benefits of the Limited Warranty throughout the warranty period If the Split Startup Checklist is incomplete Purchaser will be informed they have five days to complete the Split Startup Checklist and re submit to Whi...

Страница 25: ...f of purchase of the Product in the form of a bill of sale receipted invoice or serial number which is evidence that the Product is within the Limited Warranty Period must be presented by the End User to WhisperKOOL in order to obtain limited warranty service 7 This limited warranty is void if the factory applied serial number has been altered or removed from the Product 8 This limited warranty is...

Страница 26: ...oduct is found to be un repairable in the field contact WhisperKOOL Customer Service to arrange for replacement under the warranty guidelines When a claim for warranty is submitted for a condenser skid the End User must purchase a new condenser skid from WhisperKOOL at retail price Upon installation of the new condenser skid by a certified HVAC R Technician the HVAC R Technician must complete the ...

Страница 27: ...erKOOL will provide all documentation to the customer to substantiate the findings This will include the Invoice from the Independent Certified HVAC R Technician and the written report of the findings The Owner will become responsible for payment directly to WhisperKOOL for all charges incurred for repairs labor parts and shipping costs on the Split System 8 Miscellaneous Terms and Conditions A Re...

Страница 28: ...r please send a letter via U S Mail to Customer Service WhisperKOOL Corporation 1738 E Alpine Ave Stockton CA 95205 Email support whisperkool com Web www whisperkool com B Technical Assistance WhisperKOOL Customer Service is available Monday through Friday from 6 00 a m to 4 00 p m PST The Customer Service representative will be able to assist you with your questions and warranty information more ...

Страница 29: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com ...