PART 2: FAN MOTOR INSTALLTION GUIDE
Inline Solution
Models included: IL-800 and IP-1140
17
Positioning your KLEENAIR Unit:
It is recommended that the KLEENAIR INLINE unit be mounted
in a roof space or wall cavity. Please ensure that the KLEENAIR
unit is positioned in an environment that is free of other gases
to enable an efficient expulsion of the cooking by-products
and to ensure that back draft of external gases doesn’t take
place.
Please ensure the fan motor is positioned away from other
exhausts such as chimneys, gas flues, etc. The inline unit can
be mounted so that it ducts directly through the wall or eave
vent.
STEP 1:
Establish a suitable position in the roof or wall cavity for the
KLEENAIR unit, ensuring that the distance between the
KLEENAIR unit and the outside vent is no greater than
800mm.
The KLEENAIR unit must be located a minimum
of 3 metres from the hood unit
.
STEP 2:
Using the mounting bracket and screws, mount the KLEENAIR unit to a beam, truss or another appropriate structures in the roof
or wall space through the rubber grommets. Hang the fan motor unit from the mounting bracket ensuring the mounting bracket
is located at the top of the unit. Ensure the direction of airflow is toward the outside. The direction of airflow is marked on the
KLEENAIR unit.
STEP 3:
Cut a 200mm diameter hole in the wall or eave to enable the mounting of the external vent. Please ensure that the hole is cut in
a practical position to enable the flexi-duct to be secured. Attach the flexi-duct to the vent and then mount vent to the wall or
eave.
STEP 4:
Attach the flexi-duct from the external vent to the outlet of the KLEENAIR unit using pipe clamps. To minimise inefficiencies and
noise ensure the duct is pulled tight and the 200mm diameter is maintained.
STEP 5:
Attach flexi-duct from the KLEENAIR unit to the rangehood using pipe clamps. Ensure that the duct is pulled tightly to ensure that
flexi-duct remains firm and stable during operation. Avoid sharp bends in the duct.
Gentle bends in the ducting are
recommended as it assists in muffling noise from the fan motor unit back to the rangehood
. If the flexi-duct needs to be
extended attach two flexi-duct ends using a rigid duct insert and secured by pipe clamps (Optional installation accessories
HBX200DUCT).
STEP 6:
Attach the male plug of the KLEENAIR unit to the female plug of the rangehood to enable power supply to the fan motor unit. An
extension lead (not supplied) of up to five meters may be added if required.
Outlet
Mounting Bracket
Inlet